CoChat

Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis

Arrese, Ignacio, Sarabia, Rosario, Pintado, Rebeca, Delgado-Rodriguez, Miguel · 2013 · Neurosurgery
Cited by 171

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Although the introduction of flow-diverter devices (FDDs) has aroused great enthusiasm, the level of evidence supporting their use has not been systematically evaluated. OBJECTIVE: To report a systematic review of medical literature up to May 2012 on FDDs to assess the morbidity, case fatality rate, and efficacy of FDDs for intracranial aneurysms. METHODS: The literature was searched by using MEDLINE, Embase, and all Evidence-Based Medicine in the OVID database. Eligibility criteria were studies including at least 10 patients, reporting duration of follow-up and number of patients lost to follow-up, and documenting the rate of aneurysm occlusion and death and neurological complications. The endpoints were angiographic success, early and late mortality, and neurological morbidity. RESULTS: Fifteen studies were analyzed consisting of 897 patients with 1018 aneurysms. The mean value of methodological quality score was 14.4 using the STROBE score. The early mortality rate was 2.8% (95% confidence interval [CI]: 1.7-3.8; I(2) = 93.4%) and the late mortality rate was 1.3% (95% CI: 0.2-2.3; I(2) = 36.9%). The early neurological morbidity rate was 7.3% (95% CI: 5.7-9; I(2) = 91.8%) and the late morbidity rate was 2.6% (95% CI: 1.1-4; I(2) = 81.3%). The Egger test for early and late morbidity and aneurysm occlusion was <0.001. CONCLUSION: With the available data from the studies, both heterogeneity and publication biases imply that the current clinical use of FDDs is not supported by high-quality evidence. In the absence of reliable evidence, the use of FDDs in patients eligible for more conventional treatments should be restricted to controlled clinical trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1227/01.neu.0000430297.17961.f1

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 171

Metadata

Authors
Arrese, I., Sarabia, R., Pintado, R., & Delgado-Rodriguez, M.
Venue
Neurosurgery
Published
2013-08
Volume
73
Issue
2
Pages
193-200
ISSN
0148-396X (ISSN-L)
OpenAlex
W1980984708
Cited by
171
References
2
FWCI
12.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1227/01.neu.0000430297.17961.f1
The paper
Arrese, I., Sarabia, R., Pintado, R., & Delgado-Rodriguez, M. (2013). Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis. Neurosurgery. https://doi.org/10.1227/01.neu.0000430297.17961.f1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.