Towards a Unified Testing Framework for Single-Sided Deafness Studies: A Consensus Paper
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Background: While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL. Methods: This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada. Results: A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable. Conclusion: A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Health Utilities Index (HUI): concepts, measurement properties and applications.
Horsman, J., Furlong, W. J., Feeny, D. F., & Torrance, G. W. (2003) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-1-54 · Cited by 1,598 · cited 1×
“Generic QoL Questionnaire As a generic measure of general health status, the Health Utilities Index Mark 3 [Horsman et al., 2003] should be used to SSD Consensus Audiol Neurotol 2016;21:391–398 DOI: 10.1159/000455058 397 evaluate a single index value of the health status.”
MethodInfluentialThe Tinnitus Functional Index: Development of a New Clinical Measure for Chronic, Intrusive Tinnitus
Meikle, M. B., Henry, J. A., Griest, S. E., Stewart, B. J., Abrams, H. B., McArdle, R., Myers, P. J., Newman, C. W., Sandridge, S., Turk, D. C., et al. (2012) · Ear & Hearing · doi:10.1097/aud.0b013e31822f67c0 · Cited by 792 · cited 1×
“…with tinnitus of the types falling into the CI indication criteria as put forward by Van de Heyning et al. [2008], the tinnitus functional index questionnaire [Meikle et al., 2012] should be used to assess the handicap from tinnitus at the preoperative interval and at all follow-up intervals.”
MethodArndt, S., Aschendorff, A., Laszig, R., Beck, R., Schild, C., Kroeger, S., Ihorst, G., & Wesarg, T. (2011) · Otology & Neurotology · doi:10.1097/mao.0b013e3181fcf271 · Cited by 514 · cited 1×
“…with SSD or AHL with better speech perception in spatially separated noise, better sound localization, better QoL, and a decreased severity and incidence of tinnitus [Arndt et al., 2011; Tokita et al., 2014; van Zon et al., 2015; Vlastarakos et al., 2014] than a CROS-HA, BAHA, or nontreatment.”
BackgroundSelf-citationIncapacitating Unilateral Tinnitus in Single-Sided Deafness Treated by Cochlear Implantation
Van de Heyning, P., Vermeire, K., Diebl, M., Nopp, P., Anderson, I., & De Ridder, D. (2008) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940811700903 · Cited by 413 · cited 1×
“…have been done to this end [Arndt et al., 2017; Jacob and Stelzig, 2011; Mertens et al., 2015, 2016a, b; Távora-Vieira et al., 2013a, 2015; Van de Heyning et al., 2008; Vermeire and Van de Heyning, 2009], and systematic reviews of the available literature have found that a CI can provide adults…”
BackgroundSelf-citationVermeire, K., & Van de Heyning, P. (2009) · Audiology and Neurotology · doi:10.1159/000171478 · Cited by 337
Self-citationCochlear Implantation for Patients With Single-Sided Deafness or Asymmetrical Hearing Loss
van Zon, A., Peters, J. P. M., Stegeman, I., Smit, A. L., & Grolman, W. (2014) · Otology & Neurotology · doi:10.1097/mao.0000000000000681 · Cited by 151 · cited 3×
“CI users with SSD or AHL, however, have consistently been found to perform equally or better with the CI activated in this configuration, suggesting that a CI is able to reinstate binaural hearing [van Zon et al., 2015].”
BackgroundResultTávora‐Vieira, D., Marino, R., Acharya, A. N., & Rajan, G. P. (2015) · Otology & Neurotology · doi:10.1097/mao.0000000000000707 · Cited by 140 · cited 1×
“Studies have been done to this end [Arndt et al., 2017; Jacob and Stelzig, 2011; Mertens et al., 2015, 2016a, b; Távora-Vieira et al., 2013a, 2015; Van de Heyning et al., 2008; Vermeire and Van de Heyning, 2009], and systematic reviews of the available literature have found that a CI can provide…”
BackgroundSelf-citationCochlear implantation for single-sided deafness: the outcomes. An evidence-based approach
Vlastarakos, P. V., Nazos, K., Tavoulari, E., & Nikolopoulos, T. P. (2013) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-013-2746-z · Cited by 112 · cited 1×
“…with SSD or AHL with better speech perception in spatially separated noise, better sound localization, better QoL, and a decreased severity and incidence of tinnitus [Arndt et al., 2011; Tokita et al., 2014; van Zon et al., 2015; Vlastarakos et al., 2014] than a CROS-HA, BAHA, or nontreatment.”
BackgroundMertens, G., De Bodt, M., & Van de Heyning, P. (2016) · Hearing Research · doi:10.1016/j.heares.2015.09.016 · Cited by 103 · cited 1×
“Studies have been done to this end [Arndt et al., 2017; Jacob and Stelzig, 2011; Mertens et al., 2015, 2016a, b; Távora-Vieira et al., 2013a, 2015; Van de Heyning et al., 2008; Vermeire and Van de Heyning, 2009], and systematic reviews of the available literature have found that a CI can provide…”
BackgroundSelf-citationCochlear implantation for unilateral deafness with and without tinnitus: A case series
Távora‐Vieira, D., Marino, R., Krishnaswamy, J., Kuthbutheen, J., & Rajan, G. P. (2013) · The Laryngoscope · doi:10.1002/lary.23764 · Cited by 95
Self-citationMertens, G., Punte, A. K., Bodt, M. S. D., & de Heyning, P. V. (2015) · Audiology and Neurotology · doi:10.1159/000380751 · Cited by 91 · cited 1×
“Studies have been done to this end [Arndt et al., 2017; Jacob and Stelzig, 2011; Mertens et al., 2015, 2016a, b; Távora-Vieira et al., 2013a, 2015; Van de Heyning et al., 2008; Vermeire and Van de Heyning, 2009], and systematic reviews of the available literature have found that a CI can provide…”
BackgroundSelf-citationBernstein, J. G. W., Goupell, M. J., Schuchman, G. I., Rivera, A. L., & Brungart, D. S. (2016) · Ear and Hearing · doi:10.1097/aud.0000000000000284 · Cited by 88 · cited 1×
“If possible, same-gender 2-talker babble should be used as the masking signal, because it has been shown to be (1) a more effective speech masker than other noise signals and (2) more sensitive in demonstrating benefits of a CI or a second good ear over a first good ear [Bernstein et al., 2016].”
MethodInvestigating Long-Term Effects of Cochlear Implantation in Single-Sided Deafness
Gartrell, B. C., Jones, H. G., Kan, A., Buhr-Lawler, M., Gubbels, S. P., & Litovsky, R. Y. (2014) · Otology & Neurotology · doi:10.1097/mao.0000000000000437 · Cited by 63 · cited 1×
“Head shadow, summation, binaural squelch, and spatial release from masking are measures of binaural benefit that can be derived from the proposed testing configurations [Gartrell et al., 2014].”
MethodKitterick, P. T., O’Donoghue, G. M., Edmondson‐Jones, M., Marshall, A., Jeffs, E., Craddock, L. C., Riley, A., Green, K. M. J., O’Driscoll, M. P., Jiang, D., et al. (2014) · BMC Ear Nose and Throat Disorders · doi:10.1186/1472-6815-14-7 · Cited by 35 · cited 1×
“…Kleine Punte and Van de Heyning, 2013], (2) study protocols for the evaluation of the benefits of CI, BCD, and CROS/BiCROS-HAs in treating SSD [Kitterick et al., 2014; Peters et al., 2015a], and (3) recommendations for the identification and evaluation of CI candidates with AHL [Vincent et…”
BackgroundPeters, J. P. M., van Zon, A., Smit, A. L., van Zanten, G. A., de Wit, G. A., Stegeman, I., & Grolman, W. (2015) · BMC Ear Nose and Throat Disorders · doi:10.1186/s12901-015-0016-y · Cited by 35 · cited 2×
“…dB in normalhearing listeners [Bronkhorst and Plomp, 1988], CROS-HA and BCD devices consistently show a decrement in speech recognition in this configuration [Peters et al., 2015b] because they essentially route the masker to the better ear and therefore reduce the effective TMR ratio on that side.”
Background
Metadata
- Authors
- Van de Heyning, P., Távora-Vieira, D., Mertens, G., Van Rompaey, V., Rajan, G. P., Müller, J., Hempel, J. M., Leander, D., Polterauer, D., Marx, M., Usami, S.-I., Kitoh, R., Miyagawa, M., Moteki, H., Smilsky, K., Baumgartner, W.-D., Keintzel, T. G., Sprinzl, G. M., Wolf-Magele, A., Arndt, S., Wesarg, T., Zirn, S., Baumann, U., Weissgerber, T., Rader, T., Hagen, R., Kurz, A., Rak, K., Stokroos, R., George, E., Polo, R., Medina, M. D. M., Henkin, Y., Hilly, O., Ulanovski, D., Rajeswaran, R., Kameswaran, M., Di Gregorio, M. F., & Zernotti, M. E.
- Venue
- Audiology and Neurotology
- Publisher
- S. Karger AG
- Published
- 2016
- Volume
- 21
- Issue
- 6
- Pages
- 391-398
- ISSN
- 1420-3030 (ISSN-L)
- 1421-9700
- OpenAlex
- W4293281715
- Cited by
- 208
- References
- 15
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.