Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 553

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Platelet microparticle membranes have 50- to 100-fold higher specific procoagulant activity than activated platelets

Kireev, Dmitry, Popenko, Nadezhda, Pichugin, Aleksei, Panteleev, Mikhail, Krymskaya, Olga, Ataullakhanov, Fazoil, Sinauridze, Elena·2007·Thrombosis and Haemostasis

Abstract

Summary: Platelet microparticles (PMPs) are small vesicles released from blood platelets upon activation. The procoagulant activity of PMPs has been previously mainly characterized by theirability to bind coagulation factors VIII and Va in reconstructed systems. It can be supposed that PMPs can contribute to the development of thrombotic complications in the pathologic states associated with the increase of their blood concentration. In this study we compared procoagulant properties of calcium ionophore A23187-activated platelets and PMPs using several in-vitro models of hemostasis. Surface densities of phosphatidylserine, CD61, CD62P and factor X bound per surface area unit were determined by flow cytometry. They were 2.7-, 8.4-, 4.3-, and 13-fold higher for PMPs than for activated platelets, respectively. Spatial clot growth rate (Vclot) in the reaction-diffus ion experimental model and endogenous thrombin potential (ETP) were determined in plasma, which was depleted of phospholipid cell surfaces by ultra-centrifugation and supplemented with activated platelets or PMPs at different concentrations. Both Vcllot and ETP rapidly increased with the increase of PMP or platelet concentration until saturation was reached. The plateau values of Vclot and ETP for activated platelets and PMPs were similar. In both assays, the procoagulant activity of one PMP was almost equal to that of one activated platelet despite at least two-orders-of-magnitude difference in their surface areas. This suggests that the PMP surface is approximately 50- to 100-fold more procoagulant than the surface of activated platelets.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1160/th06-06-0313

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 553

Metadata

Authors
Kireev, D., Popenko, N., Pichugin, A., Panteleev, M., Krymskaya, O., Ataullakhanov, F., & Sinauridze, E.
Venue
Thrombosis and Haemostasis
Published
2007
Volume
97
Issue
03
Pages
425-434
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W2168183582
Cited by
553
References
23
FWCI
7.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Platelet microparticle membranes have 50- to 100-fold higher specific procoagulant activity than activated platelets. https://app.cochat.ai/papers/10.1160/th06-06-0313
The paper
Kireev, D., Popenko, N., Pichugin, A., Panteleev, M., Krymskaya, O., Ataullakhanov, F., & Sinauridze, E. (2007). Platelet microparticle membranes have 50- to 100-fold higher specific procoagulant activity than activated platelets. Thrombosis and Haemostasis. https://doi.org/10.1160/th06-06-0313

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.