Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 786

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Microparticles: Protagonists of a Novel Communication Network for Intercellular Information Exchange

Open access
Mause, Sebastian F., Weber, Christian·2010·Circulation Research

Abstract

Microparticles represent a heterogeneous population of vesicles with a diameter of 100 to 1000 nm that are released by budding of the plasma membrane and express antigens specific of their parental cells. Although microparticle formation represents a physiological phenomenon, a multitude of pathologies are associated with a considerable increase in circulating microparticles, including inflammatory and autoimmune diseases, atherosclerosis, and malignancies. Microparticles display an broad spectrum of bioactive substances and receptors on their surface and harbor a concentrated set of cytokines, signaling proteins, mRNA, and microRNA. Recent studies provided evidence for the concept of microparticles as veritable vectors for the intercellular exchange of biological signals and information. Indeed, microparticles may transfer part of their components and content to selected target cells, thus mediating cell activation, phenotypic modification, and reprogramming of cell function. Because microparticles readily circulate in the vasculature, they may serve as shuttle modules and signaling transducers not only in their local environment but also at remarkable distance from their site of origin. Altogether, this transcellular delivery system may extend the confines of the limited transcriptome and proteome of recipient cells and establishes a communication network in which specific properties and information among cells can be efficiently shared. At least in same cases, the sequential steps of the transfer process underlie complex regulatory mechanisms, including selective sorting (“packaging”) of microparticle components and content, specificity of interactions with target cells determined by surface receptors, and ultimately finely tuned and signal-dependent release and delivery of microparticle content.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circresaha.110.226456

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 786

Metadata

Authors
Mause, S. F., & Weber, C.
Venue
Circulation Research
Published
2010-10-29
Volume
107
Issue
9
Pages
1047-1057
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2100927341
Cited by
786
References
1
FWCI
21.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microparticles: Protagonists of a Novel Communication Network for Intercellular Information Exchange. https://app.cochat.ai/papers/10.1161/circresaha.110.226456
The paper
Mause, S. F., & Weber, C. (2010). Microparticles: Protagonists of a Novel Communication Network for Intercellular Information Exchange. Circulation Research. https://doi.org/10.1161/circresaha.110.226456

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.