Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 433

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Percutaneous Left Atrial Appendage Transcatheter Occlusion to Prevent Stroke in High-Risk Patients With Atrial Fibrillation: Early Clinical Experience

Open access
Sievert, Horst, Lesh, Michael D., Trepels, Thomas, Omran, Heyder, Bartorelli, Antonio, Della Bella, Paola, Nakai, Toshiko, Reisman, Mark, DiMario, Carlo, Block, Peter, Kramer, Paul, Fleschenberg, Dirk, Krumsdorf, Ulrike, Scherer, Detlef·2002·Circulation

Abstract

Background — Thromboembolism due to atrial fibrillation (AF) is a frequent cause of stroke. More than 90% of thrombi in AF form in the left atrial appendage (LAA). Obliteration of the appendage may prevent embolic complications. Methods and Results — We evaluated the feasibility and safety of implanting a novel device for percutaneous left atrial appendage transcatheter occlusion (PLAATO). LAA occlusion using the PLAATO system was attempted in 15 patients with chronic AF at high risk for stroke, who are poor candidates for long-term warfarin therapy. The implant consists of a self-expanding nitinol cage covered with a polymeric membrane (ePTFE). The LAA was successfully occluded in 15/15 patients (100%). Angiography and transesophageal echocardiography (TEE) during the procedure showed that the device was well-seated in all patients and that there was no evidence of perforation, device embolization, or interference with surrounding structures. In 1 patient, the first procedure was complicated by a hemopericardium, which occurred during LAA access. A second attempt 30 days later was successful with no untoward sequela. No other complications occurred. At 1-month follow-up, chest fluoroscopy and TEE revealed continued stable implant position with smooth atrial-facing surface and no evidence of thrombus. Conclusions — Thus, transcatheter closure of the LAA is feasible in humans. This novel implant technology may be appropriate for patients with AF who are not suitable candidates for anticoagulation therapy. Further trials are needed to show the long-term safety and its efficacy in reducing stroke.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000015698.54752.6d

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 433

Metadata

Authors
Sievert, H., Lesh, M. D., Trepels, T., Omran, H., Bartorelli, A., Della Bella, P., Nakai, T., Reisman, M., DiMario, C., Block, P., Kramer, P., Fleschenberg, D., Krumsdorf, U., & Scherer, D.
Venue
Circulation
Published
2002-04-23
Volume
105
Issue
16
Pages
1887-1889
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2117244124
Cited by
433
References
4
FWCI
13.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous Left Atrial Appendage Transcatheter Occlusion to Prevent Stroke in High-Risk Patients With Atrial Fibrillation: Early Clinical Experience. https://app.cochat.ai/papers/10.1161/01.cir.0000015698.54752.6d
The paper
Sievert, H., Lesh, M. D., Trepels, T., Omran, H., Bartorelli, A., Della Bella, P., Nakai, T., Reisman, M., DiMario, C., Block, P., Kramer, P., Fleschenberg, D., Krumsdorf, U., & Scherer, D. (2002). Percutaneous Left Atrial Appendage Transcatheter Occlusion to Prevent Stroke in High-Risk Patients With Atrial Fibrillation: Early Clinical Experience. Circulation. https://doi.org/10.1161/01.cir.0000015698.54752.6d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.