Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 356

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Electrical Conduction in Canine Pulmonary Veins: Electrophysiological and Anatomic Correlation

Open access
Hocini, Mélèze, Ho, Siew Y., Kawara, Tokuhiro, Linnenbank, André C., Potse, Mark, Shah, Dipen, Jaïs, Pierre, Janse, Michiel J., Haïssaguerre, Michel, de Bakker, Jacques M.T. · 2002 · Circulation

Abstract

Background — Paroxysmal atrial fibrillation in patients is often initiated by foci in the pulmonary veins. The mechanism of these initiating arrhythmias is unknown. The aim of this study was to determine electrophysiological characteristics of canine pulmonary veins that may predispose to initiating arrhythmias. Methods and Results — Extracellular recordings were obtained from the luminal side of 9 pulmonary veins in 6 Langendorff-perfused dog hearts after the veins were incised from the severed end to the ostium. Pulmonary veins were paced at the distal end, the ostium, and an intermediate site. During basic and premature stimulation, extracellular electrical activity was recorded with a grid electrode that harbored 247 electrode terminals. In 4 hearts, intracellular electrograms were recorded with microelectrodes. Myocyte arrangement immediately beneath the venous walls was determined by histological analysis in 3 hearts. Extracellular mapping revealed slow and complex conduction in all pulmonary veins. Activation delay after premature stimulation could be as long as 96 ms over a distance of 3 mm. Action potential duration was shorter at the distal end of the veins than at the orifice. No evidence for automaticity or triggered activity was found. Histological investigation revealed complex arrangements of myocardial fibers that often showed abrupt changes in fiber direction and short fibers arranged in mixed direction. Conclusions — Zones of activation delay were observed in canine pulmonary veins and correlated with abrupt changes in fascicle orientation. This architecture of muscular sleeves in the pulmonary veins may facilitate reentry and arrhythmias associated with ectopic activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000016062.80020.11

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 356

Metadata

Authors
Hocini, M., Ho, S. Y., Kawara, T., Linnenbank, A. C., Potse, M., Shah, D., Jaïs, P., Janse, M. J., Haïssaguerre, M., & de Bakker, J. M. T.
Venue
Circulation
Published
2002-05-21
Volume
105
Issue
20
Pages
2442-2448
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2153905876
Cited by
356
References
14
FWCI
15.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical Conduction in Canine Pulmonary Veins: Electrophysiological and Anatomic Correlation. https://app.cochat.ai/papers/10.1161/01.cir.0000016062.80020.11
The paper
Hocini, M., Ho, S. Y., Kawara, T., Linnenbank, A. C., Potse, M., Shah, D., Jaïs, P., Janse, M. J., Haïssaguerre, M., & de Bakker, J. M. T. (2002). Electrical Conduction in Canine Pulmonary Veins: Electrophysiological and Anatomic Correlation. Circulation. https://doi.org/10.1161/01.cir.0000016062.80020.11

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.