Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Intracoronary Thrombectomy With the X-Sizer Catheter System Improves Epicardial Flow and Accelerates ST-Segment Resolution in Patients With Acute Coronary Syndrome: A Prospective, Randomized, Controlled Study

Beran, Gilbert, Lang, Irene, Schreiber, Wolfgang, Denk, Stefan, Stefenelli, Thomas, Syeda, Bonni, Maurer, Gerald, Glogar, Dietmar, Siostrzonek, Peter · 2002 · Circulation

Abstract

Background — In patients with acute coronary syndrome (ACS), percutaneous coronary intervention (PCI) may cause thrombus dislodgment followed by reduced flow and impaired microcirculatory function. We prospectively compared conventional PCI to a strategy of additional pretreatment using the X-sizer thrombectomy system. Methods and Results — Sixty-six patients (51 [77%] men; 54.9±9.9 years) with ACS (49 with ST-elevation infarction [STEMI]) and suspected intracoronary thrombus were randomized 1:1 to pretreatment with X-sizer and conventional PCI alone. Various aspects of epicardial flow and microvascular function were studied. Baseline data were similar in both groups. Postprocedural TIMI 3 flow was obtained in 90% of X-sizer–treated patients and in 84% of controls (NS); however, corrected TIMI frame count was lower in X-sizer– treated patients (18.3±10.2 versus 24.7±14.1; P <0.05). No significant group differences were observed in final coronary flow reserve, myocardial blush grade, and myocardial dye intensity. In STEMI, the sum of ST elevation was significantly lower in X-sizer–treated patients immediately after (2.78±3.05 versus 6.15±6.32 mm; P <0.03) and 6 hours after (2.17±2.31 versus 4.14±3.7 mm; P <0.05) intervention. ST-segment resolution >50% was observed in 83% of X-sizer–treated patients and in 52% of controls ( P <0.03). Multivariate analysis identified X-sizer treatment as the single independent predictor of ST-segment resolution >50% (OR 4.35; 95% CI, 1.13 to 16.9; P <0.04). Major adverse cardiac events after 30 days occurred in 2 patients in each group. Conclusions — In ACS with suspected thrombus, pretreatment with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution compared with conventional PCI alone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000016350.02669.1d

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 162

Metadata

Authors
Beran, G., Lang, I., Schreiber, W., Denk, S., Stefenelli, T., Syeda, B., Maurer, G., Glogar, D., & Siostrzonek, P.
Venue
Circulation
Published
2002-05-21
Volume
105
Issue
20
Pages
2355-2360
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2074717148
Cited by
162
References
1
FWCI
15.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intracoronary Thrombectomy With the X-Sizer Catheter System Improves Epicardial Flow and Accelerates ST-Segment Resolution in Patients With Acute Coronary Syndrome: A Prospective, Randomized, Controlled Study. https://app.cochat.ai/papers/10.1161/01.cir.0000016350.02669.1d
The paper
Beran, G., Lang, I., Schreiber, W., Denk, S., Stefenelli, T., Syeda, B., Maurer, G., Glogar, D., & Siostrzonek, P. (2002). Intracoronary Thrombectomy With the X-Sizer Catheter System Improves Epicardial Flow and Accelerates ST-Segment Resolution in Patients With Acute Coronary Syndrome: A Prospective, Randomized, Controlled Study. Circulation. https://doi.org/10.1161/01.cir.0000016350.02669.1d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.