B-Type Natriuretic Peptide and Clinical Judgment in Emergency Diagnosis of Heart Failure: Analysis From Breathing Not Properly (BNP) Multinational Study

McCullough, Peter A., Nowak, Richard M., McCord, James, Hollander, Judd E., Herrmann, Howard C., Steg, Philippe G., Duc, Philippe, Westheim, Arne, Omland, Torbjørn, Knudsen, Cathrine Wold, Storrow, Alan B., Abraham, William T., Lamba, Sumant, Wu, Alan H.B., Perez, Alberto, Clopton, Paul, Krishnaswamy, Padma, Kazanegra, Radmila, Maisel, Alan S.·2002·Circulation

Abstract

Background — We sought to determine the degree to which B-type natriuretic peptide (BNP) adds to clinical judgment in the diagnosis of congestive heart failure (CHF). Methods and Results — The Breathing Not Properly Multinational Study was a prospective diagnostic test evaluation study conducted in 7 centers. Of 1586 participants who presented with acute dyspnea, 1538 (97%) had clinical certainty of CHF determined by the attending physician in the emergency department. Participants underwent routine care and had BNP measured in a blinded fashion. The reference standard for CHF was adjudicated by 2 independent cardiologists, also blinded to BNP results. The final diagnosis was CHF in 722 (47%) participants. At an 80% cutoff level of certainty of CHF, clinical judgment had a sensitivity of 49% and specificity of 96%. At 100 pg/mL, BNP had a sensitivity of 90% and specificity of 73%. In determining the correct diagnosis (CHF versus no CHF), adding BNP to clinical judgment would have enhanced diagnostic accuracy from 74% to 81%. In those participants with an intermediate (21% to 79%) probability of CHF, BNP at a cutoff of 100 pg/mL correctly classified 74% of the cases. The areas under the receiver operating characteristic curve were 0.86 (95% CI 0.84 to 0.88), 0.90 (95% CI 0.88 to 0.91), and 0.93 (95% CI 0.92 to 0.94) for clinical judgment, for BNP at a cutoff of 100 pg/mL, and for the 2 in combination, respectively ( P <0.0001 for all pairwise comparisons). Conclusions — The evaluation of acute dyspnea would be improved with the addition of BNP testing to clinical judgment in the emergency department.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000025242.79963.4c

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 879

Metadata

Authors
McCullough, P. A., Nowak, R. M., McCord, J., Hollander, J. E., Herrmann, H. C., Steg, P. G., Duc, P., Westheim, A., Omland, T., Knudsen, C. W., Storrow, A. B., Abraham, W. T., Lamba, S., Wu, A. H. B., Perez, A., Clopton, P., Krishnaswamy, P., Kazanegra, R., & Maisel, A. S.
Venue
Circulation
Published
2002-07-23
Volume
106
Issue
4
Pages
416-422
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2096254491
Cited by
879
References
1
FWCI
39.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: B-Type Natriuretic Peptide and Clinical Judgment in Emergency Diagnosis of Heart Failure: Analysis From Breathing Not Properly (BNP) Multinational Study. https://app.cochat.ai/papers/10.1161/01.cir.0000025242.79963.4c
The paper
McCullough, P. A., Nowak, R. M., McCord, J., Hollander, J. E., Herrmann, H. C., Steg, P. G., Duc, P., Westheim, A., Omland, T., Knudsen, C. W., Storrow, A. B., Abraham, W. T., Lamba, S., Wu, A. H. B., Perez, A., Clopton, P., Krishnaswamy, P., Kazanegra, R., & Maisel, A. S. (2002). B-Type Natriuretic Peptide and Clinical Judgment in Emergency Diagnosis of Heart Failure: Analysis From Breathing Not Properly (BNP) Multinational Study. Circulation. https://doi.org/10.1161/01.cir.0000025242.79963.4c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.