Effect of Annular Shape on Leaflet Curvature in Reducing Mitral Leaflet Stress

Open access
Salgo, Ivan S., Gorman, Joseph H., Gorman, Robert C., Jackson, Benjamin M., Bowen, Frank W., Plappert, Theodore, St John Sutton, Martin G., Edmunds, L. Henry·2002·Circulation

Abstract

Background — Leaflet curvature is known to reduce mechanical stress. There are 2 major components that contribute to this curvature. Leaflet billowing introduces the most obvious form of leaflet curvature. The saddle shape of the mitral annulus imparts a more subtle form of leaflet curvature. This study explores the relative contributions of leaflet billowing and annular shape on leaflet curvature and stress distribution. Methods and Results — Both numerical simulation and experimental data were used. The simulation consisted of an array of numerically generated mitral annular phantoms encompassing flat to markedly saddle-shaped annular heights. Highest peak leaflet stresses occurred for the flat annulus. As saddle height increased, peak stresses decreased. The minimum peak leaflet stress occurred at an annular height to commissural width ratio of 15% to 25%. The second phase involved data acquisition for the annulus from 3 humans by 3D echocardiography, 3 sheep by sonomicrometry array localization, 2 sheep by 3D echocardiography, and 2 baboons by 3D echocardiography. All 3 species imaged had annuli of a similar shape, with an annular height to commissural width ratio of 10% to 15%. Conclusion — The saddle shape of the mitral annulus confers a mechanical advantage to the leaflets by adding curvature. This may be valuable when leaflet curvature becomes reduced due to diminished leaflet billowing caused by annular dilatation. The fact that the saddle shape is conserved across mammalian species provides indirect evidence of the advantages it confers. This analysis of mitral annular contour may prove applicable in developing the next generation of mitral annular prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000025426.39426.83

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 445

Metadata

Authors
Salgo, I. S., Gorman, J. H., Gorman, R. C., Jackson, B. M., Bowen, F. W., Plappert, T., St John Sutton, M. G., & Edmunds, L. H.
Venue
Circulation
Published
2002-08-06
Volume
106
Issue
6
Pages
711-717
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2132567621
Cited by
445
References
0
FWCI
6.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Annular Shape on Leaflet Curvature in Reducing Mitral Leaflet Stress. https://app.cochat.ai/papers/10.1161/01.cir.0000025426.39426.83
The paper
Salgo, I. S., Gorman, J. H., Gorman, R. C., Jackson, B. M., Bowen, F. W., Plappert, T., St John Sutton, M. G., & Edmunds, L. H. (2002). Effect of Annular Shape on Leaflet Curvature in Reducing Mitral Leaflet Stress. Circulation. https://doi.org/10.1161/01.cir.0000025426.39426.83

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.