Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 292

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Cardiac Grafting of Engineered Heart Tissue in Syngenic Rats

Zimmermann, Wolfram-Hubertus, Didié, Michael, Wasmeier, Gerald H., Nixdorff, Uwe, Hess, Andreas, Melnychenko, Ivan, Boy, Oliver, Neuhuber, Winfried L., Weyand, Michael, Eschenhagen, Thomas·2002·Circulation

Abstract

Background Cell grafting has emerged as a novel approach to treat heart diseases refractory to conventional therapy. We hypothesize that survival and functional and electrical integration of grafts may be improved by engineering cardiac tissue constructs in vitro before grafting. Methods and Results Engineered heart tissue (EHT) was reconstituted by mixing cardiac myocytes from neonatal Fischer 344 rats with liquid collagen type I, matrigel, and serum-containing culture medium. EHTs were designed in circular shape (inner/outer diameter: 8/10 mm; thickness: 1 mm) to fit around the circumference of hearts from syngenic rats. After 12 days in culture and before implantation on uninjured hearts, contractile function of EHT was measured under isometric conditions. Baseline twitch tension amounted to 0.34±0.03 mN (n=33) and was stimulated by Ca 2+ and isoprenaline to 200±12 and 185±10% of baseline values, respectively. Despite utilization of a syngenic model immunosuppression (mg/kg BW: azathioprine 2, cyclosporine A 5, methylprednisolone 2) was necessary for EHT survival in vivo. Echocardiography conducted 7, 14, and 28 days after implantation demonstrated no change in left ventricular function compared with pre-OP values (n=9). Fourteen days after implantation, EHTs were heavily vascularized and retained a well organized heart muscle structure as indicated by immunolabeling of actinin, connexin 43, and cadherins. Ultrastructural analysis demonstrated that implanted EHTs surpassed the degree of differentiation reached before implantation. Contractile function of EHT grafts was preserved in vivo. Conclusions EHTs can be employed for tissue grafting approaches and might serve as graft material to repair diseased myocardium.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000032876.55215.10

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 292

Metadata

Authors
Zimmermann, W.-H., Didié, M., Wasmeier, G. H., Nixdorff, U., Hess, A., Melnychenko, I., Boy, O., Neuhuber, W. L., Weyand, M., & Eschenhagen, T.
Venue
Circulation
Published
2002-09-24
Volume
106
Issue
12_suppl_1
Pages
I151-7
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2095626826
Cited by
292
References
26
FWCI
11.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Grafting of Engineered Heart Tissue in Syngenic Rats. https://app.cochat.ai/papers/10.1161/01.cir.0000032876.55215.10
The paper
Zimmermann, W.-H., Didié, M., Wasmeier, G. H., Nixdorff, U., Hess, A., Melnychenko, I., Boy, O., Neuhuber, W. L., Weyand, M., & Eschenhagen, T. (2002). Cardiac Grafting of Engineered Heart Tissue in Syngenic Rats. Circulation. https://doi.org/10.1161/01.cir.0000032876.55215.10

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.