Exercise Anaerobic Threshold and Ventilatory Efficiency Identify Heart Failure Patients for High Risk of Early Death
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Background— The maximal oxygen uptake (peak V̇ o 2 ) is used in risk stratification of patients with chronic heart failure (CHF). Peak V̇ o 2 might be lower than maximally possible if exercise is stopped early because of lack of patient motivation or premature cessation by the investigator. In contrast, the anaerobic threshold (V̇ o 2 AT) and the ventilatory efficiency (V̇ e versus V̇ co 2 slope) are less subject to these influences. Thus, we compared these parameters with peak V̇ o 2 in identifying patients with CHF at increased risk for death within 6 months after evaluation. Methods and Results— We performed cardiopulmonary exercise tests with gas exchange measurements in 223 consecutive patients with CHF (114 coronary artery disease, 92 dilated cardiomyopathy, 17 others) at the Herzzentrum Ludwigshafen between 1995 and 1998. We measured peak V̇ o 2 , V̇ o 2 AT and V̇ e versus V̇ co 2 slope. We selected peak V̇ o 2 of ≤14 mL/kg per minute, V̇ o 2 AT of <11 mL/kg per minute, and V̇ e versus V̇ co 2 slope of >34 as threshold values for high risk of death. The median follow-up time was 644 days. Patients with peak V̇ o 2 of ≤14 mL/kg per minute had a >3-fold-increased risk (OR=3.4; CI, 1.3 to 9.1), with V̇ o 2 AT <11 mL/min per kg or V̇ e versus V̇ co 2 slope >34 a 5-fold increased risk for early death (OR=5.3; CI, 1.5 to 19.0; OR=4.8; CI, 1.7 to 13.8, respectively). In patients with both V̇ o 2 AT <11 mL/kg per minute and V̇ e versus V̇ co 2 slope >34, the risk of early death was 10-fold higher (OR=9.6; CI, 2.1 to 44.7). After correction for age, sex, left ventricular ejection fraction, and New York Heart Association class in a multivariate analysis, the combination of V̇ o 2 AT <11 mL/kg per minute and V̇ e versus V̇ co 2 slope >34 was the best predictor of 6-month mortality (RR=5.1, P =0.001). Conclusions— V̇ o 2 AT of <11 mL/kg per minute and slope of V̇ e versus V̇ co 2 >34, combined, better identified patients at high risk for early death from CHF than did peak V̇ o 2 and should therefore be considered when prioritizing patients for heart transplantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Carvedilol on Morbidity and Mortality in Patients with Chronic Heart Failure
Packer, M., Bristow, M. R., Cohn, J. N., Colucci, W. S., Fowler, M. B., Gilbert, E. M., & Shusterman, N. H. (1996) · New England Journal of Medicine · doi:10.1056/nejm199605233342101 · Cited by 4,649
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Self-citationPrinciples of Exercise Testing and Interpretation.
(1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-106-4-646 · Cited by 2,359
Mancini, D. M., Eisen, H., Kussmaul, W., Mull, R., Edmunds, L. H., & Wilson, J. R. (1991) · Circulation · doi:10.1161/01.cir.83.3.778 · Cited by 1,882
Packer, M., Colucci, W. S., Sackner-Bernstein, J. D., Liang, C.-S., Goldscher, D. A., Freeman, I., Kukin, M. L., Kinhal, V., Udelson, J. E., Klapholz, M., et al. (1996) · Circulation · doi:10.1161/01.cir.94.11.2793 · Cited by 613
Chua, T. P., Ponikowski, P., Harrington, D., Anker, S. D., Webb-Peploe, K., Clark, A. L., Poole-Wilson, P. A., & Coats, A. J. S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00078-8 · Cited by 563
Optimizing the exercise protocol for cardiopulmonary assessment
Buchfuhrer, M. J., Hansen, J. E., Robinson, T. E., Sue, D. Y., Wasserman, K., & Whipp, B. J. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.55.5.1558 · Cited by 554
Self-citationCohn, J. N., Johnson, G. R., Shabetai, R. W., Loeb, H. S., Tristani, F. E., Rector, T. S., Smith, R., & Fletcher, R. D. (1993) · PubMed · Cited by 533
Impairment of Ventilatory Efficiency in Heart Failure: Prognostic Impact
Kleber, F. X., Vietzke, G., Wernecke, K. D., Bauer, U., Opitz, C., Wensel, R., Sperfeld, A., & Gläser, S. (2000) · Circulation · doi:10.1161/01.cir.101.24.2803 · Cited by 360
Stelken, A. M., Younis, L. T., Jennison, S. H., Douglas Miller, D., Miller, L. W., Shaw, L. J., Kargl, D., & Chaitman, B. R. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00464-5 · Cited by 342
Task force 3: Recipient guidelines/prioritization
Mudge, G. H., Goldstein, S., Addonizio, L. J., Caplan, A., Mancini, D., Levine, T. B., Ritsch, M. E., & Stevenson, L. W. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90812-f · Cited by 282
Myers, J., Gullestad, L., Vagelos, R., Do, D., Bellin, D., Ross, H., & Fowler, M. B. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-4-199808150-00004 · Cited by 271
Safety and efficacy of carvedilol in severe heart failure
Cohn, J. N., Fowler, M. B., Bristow, M. R., Colucci, W. S., Gilbert, E. M., Kinhal, V., Krueger, S. K., Lejemtel, T., Narahara, K. A., Packer, M., et al. (1997) · Journal of Cardiac Failure · doi:10.1016/s1071-9164(97)90013-0 · Cited by 221
Osman, A. F., Mehra, M. R., Lavie, C. J., Nunez, E., & Milani, R. V. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00985-2 · Cited by 198
Francis, G. S., Goldsmith, S. R., & Cohn, J. N. (1982) · American Heart Journal · doi:10.1016/0002-8703(82)90003-5 · Cited by 188
Improvement in exercise capacity of candidates awaiting heart transplantation
Stevenson, L. W., Steimle, A. E., Fonarow, G., Kermani, M., Kermani, D., Hamilton, M. A., Moriguchi, J. D., Walden, J., Tillisch, J. H., Drinkwater, D. C., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00357-v · Cited by 179
Francis, G. S., Goldsmith, S. R., Ziesche, S. M., & Cohn, J. N. (1982) · The American Journal of Cardiology · doi:10.1016/0002-9149(82)90039-x · Cited by 170
Exercise Testing in the Evaluation of the Patient with Chronic Cardiac Failure 1– 3
Weber, K. T., Wilson, J. R., Janicki, J. S., & Likoff, M. J. (1984) · American Review of Respiratory Disease · doi:10.1164/arrd.1984.129.2p2.s60 · Cited by 78
Exercise gas exchange in heart disease
Wasserman, K. (1995) · Futura Pub. Co. eBooks · Cited by 76
Self-citationSmith, R. F., Johnson, G. R., Ziesche, S., Bhat, G., Blankenship, K., & Cohn, J. N. (1993) · PubMed · Cited by 60
Selection and management of candidates for heart transplantation
Stevenson, L. W. (1996) · Current Opinion in Cardiology · doi:10.1097/00001573-199603000-00010 · Cited by 32
Weber, K. T., Janicki, J. S., Ward, D. M., & McElroy, P. A. (1987) · The Journal of Clinical Monitoring · doi:10.1007/bf00770881 · Cited by 8
Cited by
Balady, G. J., Arena, R., Sietsema, K., Myers, J., Coke, L., Fletcher, G. F., Forman, D., Franklin, B., Guazzi, M., Gulati, M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181e52e69 · Cited by 1,964
Mehra, M. R., Kobashigawa, J., Starling, R., Russell, S., Uber, P. A., Parameshwar, J., Mohacsi, P., Augustine, S., Aaronson, K., & Barr, M. (2006) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2006.06.008 · Cited by 966
Arena, R., Myers, J., Williams, M. A., Gulati, M., Kligfield, P., Balady, G. J., Collins, E., & Fletcher, G. (2007) · Circulation · doi:10.1161/circulationaha.106.184461 · Cited by 727
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Controlled Trial of Continuous Positive Airway Pressure in Obstructive Sleep Apnea and Heart Failure
Mansfield, D. R., Gollogly, N. C., Kaye, D. M., Richardson, M., Bergin, P., & Naughton, M. T. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-752oc · Cited by 617
“Our group mean baseline V ˙ o2 peak of approximately 17.5 ml/minute/kg was similar to that reported in patient survivors with CHF (16.4 ml/minute/ kg) and was significantly greater than that of nonsurvivors (13.2 ml/minute/kg) in a large prospective 3-year study ( 35 ).”
ResultInfluential
Metadata
- Authors
- Gitt, A. K., Wasserman, K., Kilkowski, C., Kleemann, T., Kilkowski, A., Bangert, M., Schneider, S., Schwarz, A., & Senges, J.
- Venue
- Circulation
- Published
- 2002-12-10
- Volume
- 106
- Issue
- 24
- Pages
- 3079-3084
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1985936920
- Cited by
- 491
- References
- 22
- FWCI
- 22.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.