The DOI matches its Crossref record.
Ultrasound Assessment of Inflammation and Renal Tissue Injury With Microbubbles Targeted to P-Selectin
Open accessAbstract
Background Routine methods capable of assessing tissue inflammation noninvasively are currently not available. We hypothesized that tissue retention of microbubbles targeted to the endothelial cell adhesion molecule P-selectin would provide a means to assess inflammation with ultrasound imaging. Methods and Results Phospholipid microbubbles targeted to P-selectin (MB p ) were created by conjugating monoclonal antibodies against murine P-selectin to the lipid shell. The microvascular behaviors of MB p and control microbubbles without antibody (MB) or with isotype control antibody (MB iso ) were assessed by intravital microscopy of cremasteric venules of control and tumor necrosis factor (TNF)-α–stimulated wild-type mice. Retention of all microbubbles increased ( P <0.05) with TNF-α treatment because of increased attachment to activated leukocytes. Extensive attachment of MB p directly to the venular endothelium or to adherent platelet-leukocyte aggregates was observed in TNF-α–stimulated mice, resulting in 4-fold greater ( P <0.01) retention of MB p than either MB iso or MB. Enhanced retention of MB p was completely abolished in TNF-α–stimulated P-selectin–deficient mice. The ultrasound signal from microbubbles retained in inflamed tissue was assessed by contrast-enhanced renal ultrasound imaging of the kidneys of mice undergoing ischemia-reperfusion injury. In wild-type mice, this signal was significantly higher ( P <0.05) for MB p (12±2 U) than either MB iso (6±3 U) or MB (5±3 U). In P-selectin–deficient mice, the signal for MB p was equivalent to that from control microbubbles. Conclusions Microvascular retention of microbubbles targeted to P-selectin produces strong signal enhancement on ultrasound imaging of inflamed tissue. These results suggest that site-targeted microbubbles may be used to assess inflammation, tissue injury, and other endothelial responses noninvasively with ultrasound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Self-citationNoninvasive Assessment of Angiogenesis by Ultrasound and Microbubbles Targeted to α v -Integrins
Leong-Poi, H., Christiansen, J., Klibanov, A. L., Kaul, S., & Lindner, J. R. (2003) · Circulation · doi:10.1161/01.cir.0000044916.05919.8b · Cited by 334
Self-citationMolecular imaging of cardiovascular disease with contrast-enhanced ultrasonography
Lindner, J. R. (2009) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2009.77 · Cited by 111
Self-citationPBCA-based polymeric microbubbles for molecular imaging and drug delivery
Koczera, P., Appold, L., Shi, Y., Liu, M., Dasgupta, A., Pathak, V., Ojha, T., Fokong, S., Wu, Z., van Zandvoort, M., et al. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.006 · Cited by 85
Metadata
- Authors
- Lindner, J. R., Song, J., Christiansen, J., Klibanov, A. L., Xu, F., & Ley, K.
- Venue
- Circulation
- Published
- 2001-10-23
- Volume
- 104
- Issue
- 17
- Pages
- 2107-2112
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2125542444
- Cited by
- 441
- References
- 0
- FWCI
- 13.25
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound Assessment of Inflammation and Renal Tissue Injury With Microbubbles Targeted to P-Selectin. https://app.cochat.ai/papers/10.1161/hc4201.097061
- The paper
- Lindner, J. R., Song, J., Christiansen, J., Klibanov, A. L., Xu, F., & Ley, K. (2001). Ultrasound Assessment of Inflammation and Renal Tissue Injury With Microbubbles Targeted to P-Selectin. Circulation. https://doi.org/10.1161/hc4201.097061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.