The DOI matches its Crossref record.
Local Drug Delivery via a Coronary Stent With Programmable Release Pharmacokinetics
Open accessAbstract
Background— Fixed drug release kinetics and vessel wall partitioning may limit the effectiveness of drug-eluting stents. We report preliminary experience using a new coronary stent with programmable pharmacokinetics. Methods and Results— A newly designed metallic stent contains honeycombed strut elements with inlaid stacked layers of drug and polymer. In vitro studies evaluated recipes for loading paclitaxel to establish the parameters for controlling drug release. Manipulation of the layers of biodegradable polymer and drug allowed varying of the initial 24-hour burst release of paclitaxel from 69% to 8.6% ( P <0.0001). Late release of drug could be adjusted dependently or independently of early burst release. A biphasic release profile was created by the addition of blank layers of polymer within the stack. In the 30-day porcine coronary model (n=17 pigs), there was a 70% reduction in late loss (0.3±0.5 versus 1.0±0.5 mm, P =0.04), a 28% increase in luminal volume (132±12 versus 103±21 mm 3 , P =0.02), and a 50% decrease in histological neointimal area (2.0±0.5 versus 4.0±1.6 mm 2 ; P <0.001) compared with bare metal controls. Temporal and regional variations in vascular healing were seen histologically. Conclusions— Layered polymer/drug inlay stent technology permits flexible and controllable pharmacokinetic profiles. Programmable, complex chemotherapy using this approach may be feasible for the treatment of cardiovascular disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular Basis of Restenosis and Drug-Eluting Stents
Costa, M. A., & Simon, D. I. (2005) · Circulation · doi:10.1161/01.cir.0000163587.36485.a7 · Cited by 510
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation
Hofma, S. H., van der Giessen, W. J., van Dalen, B. M., Lemos, P. A., McFadden, E. P., Sianos, G., Ligthart, J. M. R., van Essen, D., de Feyter, P. J., & Serruys, P. W. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi571 · Cited by 384
Application of Micro- and Nano-Electromechanical Devices to Drug Delivery
Staples, M., Daniel, K., Cima, M. J., & Langer, R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9906-4 · Cited by 311
Metadata
- Authors
- Finkelstein, A., McClean, D., Kar, S., Takizawa, K., Varghese, K., Baek, N., Park, K., Fishbein, M. C., Makkar, R., Litvack, F., & Eigler, N. L.
- Venue
- Circulation
- Published
- 2003-02-11
- Volume
- 107
- Issue
- 5
- Pages
- 777-784
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2162303835
- Cited by
- 170
- References
- 0
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Local Drug Delivery via a Coronary Stent With Programmable Release Pharmacokinetics. https://app.cochat.ai/papers/10.1161/01.cir.0000050367.65079.71
- The paper
- Finkelstein, A., McClean, D., Kar, S., Takizawa, K., Varghese, K., Baek, N., Park, K., Fishbein, M. C., Makkar, R., Litvack, F., & Eigler, N. L. (2003). Local Drug Delivery via a Coronary Stent With Programmable Release Pharmacokinetics. Circulation. https://doi.org/10.1161/01.cir.0000050367.65079.71
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.