Local Drug Delivery via a Coronary Stent With Programmable Release Pharmacokinetics
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background— Fixed drug release kinetics and vessel wall partitioning may limit the effectiveness of drug-eluting stents. We report preliminary experience using a new coronary stent with programmable pharmacokinetics. Methods and Results— A newly designed metallic stent contains honeycombed strut elements with inlaid stacked layers of drug and polymer. In vitro studies evaluated recipes for loading paclitaxel to establish the parameters for controlling drug release. Manipulation of the layers of biodegradable polymer and drug allowed varying of the initial 24-hour burst release of paclitaxel from 69% to 8.6% ( P <0.0001). Late release of drug could be adjusted dependently or independently of early burst release. A biphasic release profile was created by the addition of blank layers of polymer within the stack. In the 30-day porcine coronary model (n=17 pigs), there was a 70% reduction in late loss (0.3±0.5 versus 1.0±0.5 mm, P =0.04), a 28% increase in luminal volume (132±12 versus 103±21 mm 3 , P =0.02), and a 50% decrease in histological neointimal area (2.0±0.5 versus 4.0±1.6 mm 2 ; P <0.001) compared with bare metal controls. Temporal and regional variations in vascular healing were seen histologically. Conclusions— Layered polymer/drug inlay stent technology permits flexible and controllable pharmacokinetic profiles. Programmable, complex chemotherapy using this approach may be feasible for the treatment of cardiovascular disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crank, J. (1956) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,978
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Schwartz, R. S., Huber, K. C., Murphy, J. G., Edwards, W. D., Camrud, A. R., Vlietstra, R. E., & Holmes, D. R. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90476-4 · Cited by 1,175
Heldman, A. W., Cheng, L., Jenkins, G. M., Heller, P. F., Kim, D.-W., Ware, M., Nater, C., Hruban, R. H., Rezai, B., Abella, B. S., et al. (2001) · Circulation · doi:10.1161/01.cir.103.18.2289 · Cited by 435
Physiological Transport Forces Govern Drug Distribution for Stent-Based Delivery
Hwang, C.-W., Wu, D., & Edelman, E. R. (2001) · Circulation · doi:10.1161/hc3101.092214 · Cited by 426
Pathological Analysis of Local Delivery of Paclitaxel Via a Polymer-Coated Stent
Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., Scott, D. S., Froehlich, J., & Virmani, R. (2001) · Circulation · doi:10.1161/hc3001.092037 · Cited by 423
Late Coronary Occlusion After Intracoronary Brachytherapy
Costa, M. A., Sabaté, M., van der Giessen, W. J., Kay, I. P., Cervinka, P., Ligthart, J. M. R., Serrano, P., Coen, V. L. M. A., Levendag, P. C., & Serruys, P. W. (1999) · Circulation · doi:10.1161/01.cir.100.8.789 · Cited by 389
Drachman, D. E., Edelman, E. R., Seifert, P., Groothuis, A. R., Bornstein, D. A., Kamath, K. R., Palasis, M., Yang, D., Nott, S. H., & Rogers, C. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01020-2 · Cited by 286
Arterial Paclitaxel Distribution and Deposition
Creel, C. J., Lovich, M. A., & Edelman, E. R. (2000) · Circulation Research · doi:10.1161/01.res.86.8.879 · Cited by 279
Biocompatibility aspects of new stent technology
Bertrand, O. F., Sipehia, R., Mongrain, R., Rodés, J., Tardif, J.-C., Bilodeau, L., Côté, G., & Bourassa, M. G. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00289-7 · Cited by 201
Cited by
Molecular Basis of Restenosis and Drug-Eluting Stents
Costa, M. A., & Simon, D. I. (2005) · Circulation · doi:10.1161/01.cir.0000163587.36485.a7 · Cited by 510
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
“While early bare metal stents represented early prototypes to coat to release drugs, more recent DES designs are based on drug selection and programmed release designs intimately related into the de novo stent strut and frame components [46].”
BackgroundInfluentialIndication of long-term endothelial dysfunction after sirolimus-eluting stent implantation
Hofma, S. H., van der Giessen, W. J., van Dalen, B. M., Lemos, P. A., McFadden, E. P., Sianos, G., Ligthart, J. M. R., van Essen, D., de Feyter, P. J., & Serruys, P. W. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi571 · Cited by 384
Mechanisms of controlled drug release from drug-eluting stents
Acharya, G., & Park, K. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.01.016 · Cited by 363
Self-citationApplication of Micro- and Nano-Electromechanical Devices to Drug Delivery
Staples, M., Daniel, K., Cima, M. J., & Langer, R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9906-4 · Cited by 311
Perioperative myocardial infarction—aetiology and prevention
Priebe, H.-J. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei063 · Cited by 203
Drug-eluting stents: results, promises and problems
van der Hoeven, B. L., Pires, N. M. M., Warda, H. M., Oemrawsingh, P. V., van Vlijmen, B. J. M., Quax, P. H. A., Schalij, M. J., van der Wall, E. E., & Jukema, J. W. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.01.021 · Cited by 202
“The Conor drug-eluting stent is under investigation as a specially designed drug vehicle.(29) This stent has laser-cut pockets in which different drugs at different doses with different types of polymers can be combined to get optimal drug elution over time and at different locations of the target lesion.”
BackgroundOoya, T. (2003) · Journal of Controlled Release · doi:10.1016/j.jconrel.2003.07.001 · Cited by 179
“3 Ag/ml to 39 mg/ml [10], approximating an infinite sink without requiring simulated flow conditions [11].”
BackgroundRecent advances in drug eluting stents
Puranik, A. S., Dawson, E. R., & Peppas, N. A. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.10.029 · Cited by 176
“The clinical use of Conor and CoStar stents that had a degradable PLGA membrane coat was studied for eluting paclitaxel over a sufficiently long time so as to prevent in-stent restenosis; thereby averting the need to take up high doses of paclitaxel that can be detrimental to the vascular system (Finkelstein et al., 2…”
BackgroundMethodHydrotropic agents for study of in vitro paclitaxel release from polymeric micelles
Cho, Y. W., Lee, J., Lee, S. C., Huh, K. M., & Park, K. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.03.013 · Cited by 172
“N,N-Diethylnicotinamide was used effectively to create a sink condition for the release of PTX from PLGA matrix [18].”
MethodSelf-citationIn vitro–in vivo correlation: Perspectives on model development
Lu, Y., Kim, S., & Park, K. (2011) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2011.01.010 · Cited by 165
Self-citationRelease profiles in drug-eluting stents: Issues and uncertainties
Venkatraman, S., & Boey, F. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.04.022 · Cited by 158
Metadata
- Authors
- Finkelstein, A., McClean, D., Kar, S., Takizawa, K., Varghese, K., Baek, N., Park, K., Fishbein, M. C., Makkar, R., Litvack, F., & Eigler, N. L.
- Venue
- Circulation
- Published
- 2003-02-11
- Volume
- 107
- Issue
- 5
- Pages
- 777-784
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2162303835
- Cited by
- 170
- References
- 11
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.