The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation
Abstract
AIMS: Endothelial dysfunction has been related both to progression of atherosclerotic disease and to future cardiovascular events. We assessed local epicardial endothelial function 6 months after sirolimus-eluting stent (SES) or bare metal stent (BS) implantation. METHODS AND RESULTS: In 12 patients (seven SES, five BS), endothelium-dependent vasomotion of a coronary segment 15 mm in length, starting 2 mm distal to the stent, was assessed with quantitative coronary angiography immediately after the procedure and at 6 months follow-up, after intracoronary infusion of acetylcholine. Intravascular ultrasound (IVUS) was performed and coronary flow reserve (CFR) assessed in all patients. At follow-up significant vasoconstriction was seen in SES (median 32% diameter reduction from baseline) but not in BS (median 2% reduction) patients after acetylcholine infusion (P=0.03 for SES vs. BS); endothelium-independent vasodilatation to nitrates did not differ significantly between groups (20% SES, 5% BS, P=0.14). IVUS revealed no late unhealed dissections and CFR was comparable between groups (SES 3.1 vs. BS 3.2, n.s.). CONCLUSION: SES implantation may have an adverse effect on local endothelium-dependent vasomotor responses compared with BS implantation at 6 months. Long-term clinical consequences of this observation are still unknown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationSchächinger, V., Britten, M. B., & Zeiher, A. M. (2000) · Circulation · doi:10.1161/01.cir.101.16.1899 · Cited by 2,585
Paradoxical Vasoconstriction Induced by Acetylcholine in Atherosclerotic Coronary Arteries
Ludmer, P. L., Selwyn, A. P., Shook, T. L., Wayne, R. R., Mudge, G. H., Alexander, R. W., & Ganz, P. (1986) · New England Journal of Medicine · doi:10.1056/nejm198610233151702 · Cited by 2,425
Guba, M., von Breitenbuch, P., Steinbauer, M., Koehl, G., Flegel, S., Hornung, M., Bruns, C. J., Zuelke, C., Farkas, S., Anthuber, M., et al. (2002) · Nature Medicine · doi:10.1038/nm0202-128 · Cited by 1,739
Treasure, C. B., Klein, J. L., Weintraub, W. S., Talley, J. D., Stillabower, M. E., Kosinski, A. S., Zhang, J., Boccuzzi, S. J., Cedarholm, J. C., & Alexander, R. W. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502233320801 · Cited by 1,097
&NA; (1996) · Journal of Occupational & Environmental Medicine · doi:10.1097/00043764-199605000-00005 · Cited by 1,070
Stent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Sirolimus-Eluting Stents Associated With Paradoxic Coronary Vasoconstriction
Togni, M., Windecker, S., Cocchia, R., Wenaweser, P., Cook, S., Billinger, M., Meier, B., & Hess, O. M. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.062 · Cited by 373
Local Drug Delivery via a Coronary Stent With Programmable Release Pharmacokinetics
Finkelstein, A., McClean, D., Kar, S., Takizawa, K., Varghese, K., Baek, N., Park, K., Fishbein, M. C., Makkar, R., Litvack, F., et al. (2003) · Circulation · doi:10.1161/01.cir.0000050367.65079.71 · Cited by 170
Cited by
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Self-citationErbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Vascular Responses to Drug Eluting Stents: Importance of Delayed Healing
Finn, A. V., Nakazawa, G., Joner, M., Kolodgie, F. D., Mont, E. K., Gold, H. K., & Virmani, R. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.144220 · Cited by 900
A Pooled Analysis of Data Comparing Sirolimus-Eluting Stents with Bare-Metal Stents
Spaulding, C., Daemen, J., Boersma, E., Cutlip, D. E., & Serruys, P. W. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066633 · Cited by 704
Self-citationSerruys, P. W., Onuma, Y., Dudek, D., Smits, P. C., Koolen, J., Chevalier, B., de Bruyne, B., Thuesen, L., McClean, D., van Geuns, R.-J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.05.050 · Cited by 525
Self-citation
Metadata
- Authors
- Hofma, S. H., van der Giessen, W. J., van Dalen, B. M., Lemos, P. A., McFadden, E. P., Sianos, G., Ligthart, J. M. R., van Essen, D., de Feyter, P. J., & Serruys, P. W.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-10-25
- Volume
- 27
- Issue
- 2
- Pages
- 166-170
- ISSN
- 0195-668X (ISSN-L)
- 1522-9645
- OpenAlex
- W2136414832
- Cited by
- 384
- References
- 14
- FWCI
- 28.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation. https://app.cochat.ai/papers/10.1093/eurheartj/ehi571
- The paper
- Hofma, S. H., van der Giessen, W. J., van Dalen, B. M., Lemos, P. A., McFadden, E. P., Sianos, G., Ligthart, J. M. R., van Essen, D., de Feyter, P. J., & Serruys, P. W. (2006). Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation. European Heart Journal. https://doi.org/10.1093/eurheartj/ehi571
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.