Phased-Array Intracardiac Echocardiography Monitoring During Pulmonary Vein Isolation in Patients With Atrial Fibrillation: Impact on Outcome and Complications
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Background— The objective of this study was to assess the impact of intracardiac echocardiography (ICE) on the long-term success and complications in patients undergoing pulmonary vein isolation (PVI) for treatment of atrial fibrillation (AF). Methods and Results— Three hundred fifteen patients underwent PVI for treatment of AF. Each patient underwent ostial isolation of all PVs using a cooled-tip ablation catheter. PVI was performed using circular mapping (CM) alone (group 1, 56 patients), CM and ICE (group 2, 107 patients), and CM and ICE with titration of radiofrequency energy based on visualization of microbubbles by ICE (group 3, 152 patients). After a mean follow-up time of 417±145 days, 19.6% (11 of 56), 16.8% (18 of 107), and 9.8% (15 of 152) of patients in groups 1, 2, and 3 experienced recurrence of AF, respectively. Moreover, whereas no group 3 patient experienced severe (>70%) PV stenosis, severe PV stenosis was documented in 3 (3.5%) of 56 patients in group 1 and in 2 (1.8%) of 107 patients in group 2 ( P <0.05). No embolic events were detected in group 3 patients. Conclusions— Intracardiac echocardiography improves the outcome of cooled-tip PVI. Power adjustment guided by direct visualization of microbubble formation reduces the risk of PV stenosis and improves long-term cure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary Veins
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Le Mouroux, A., Le Métayer, P., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 7,975
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins
Haïssaguerre, M., Shah, D. C., Jaïs, P., Hocini, M., Yamane, T., Deisenhofer, I., Chauvin, M., Garrigue, S., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.102.20.2463 · Cited by 952
Fúster, & Westerling, R. (2001) · Circulation · Cited by 607
Committee Members, Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., et al. (2001) · Circulation · doi:10.1161/circ.104.17.2118 · Cited by 604
Circular mapping and ablation of thepulmonary vein for treatment of atrial fibrillation
Marrouche, N. F., Dresing, T., Cole, C., Bash, D., Saad, E., Balaban, K., Pavia, S. V., Schweikert, R., Saliba, W., Abdul-Karim, A., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01972-1 · Cited by 399
Self-citationNatale, A., Pisano, E., Shewchik, J., Bash, D., Fanelli, R., Potenza, D., Santarelli, P., Schweikert, R., White, R., Saliba, W., et al. (2000) · Circulation · doi:10.1161/01.cir.102.16.1879 · Cited by 275
Self-citationMapping-guided ablation of pulmonary veins to cure atrial fibrillation
Haı̈ssaguerre, M., Shah, D. C., Jaı̈s, P., Hocini, M., Yamane, T., Deisenhofer, I., Garrigue, S., & Clémenty, J. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01186-3 · Cited by 158
Kalman, J. M., Fitzpatrick, A. P., Olgin, J. E., CHIN, M. C., Lee, R. J., Scheinman, M. M., & Lesh, M. D. (1997) · American Heart Journal · doi:10.1016/s0002-8703(97)70242-4 · Cited by 157
Chu, E. W., Kalman, J. M., Kwasman, M. A., Jue, J., Fitzgerald, P. J., Epstein, L. M., Schiller, N. B., Yock, P. G., & Lesh, M. D. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90119-8 · Cited by 146
Mangrum, J. M., Mounsey, J. P. D., Kok, L. C., Dimarco, J., & Haines, D. E. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01893-4 · Cited by 139
Ultrasound Cardioscopy: Embarking on a New Journey
Seward, J. B., Packer, D. L., Chan, R. C., Curley, M., & Tajik, A. J. (1996) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(11)62999-6 · Cited by 50
Catheter Tip Orientation Affects Radiofrequency Ablation Lesion Size in the Canine Left Ventricle
Chugh, S. S., Chan, R. C., Johnson, S. B., & Packer, D. L. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb00469.x · Cited by 48
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citation
Metadata
- Authors
- Marrouche, N. F., Martin, D. O., Wazni, O., Gillinov, A. M., Klein, A., Bhargava, M., Saad, E., Bash, D., Yamada, H., Jaber, W., Schweikert, R., Tchou, P., Abdul-Karim, A., Saliba, W., & Natale, A.
- Venue
- Circulation
- Published
- 2003-06-03
- Volume
- 107
- Issue
- 21
- Pages
- 2710-2716
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2119031453
- Cited by
- 512
- References
- 15
- FWCI
- 33.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.