The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node Dysfunction
Abstract
Background— Dual-chamber (DDDR) pacing preserves AV synchrony and may reduce heart failure (HF) and atrial fibrillation (AF) compared with ventricular (VVIR) pacing in sinus node dysfunction (SND). However, DDDR pacing often results in prolonged QRS durations (QRSd) as the result of right ventricular stimulation, and ventricular desynchronization may result. The effect of pacing-induced ventricular desynchronization in patients with normal baseline QRSd is unknown. Methods and Results— Baseline QRSd was obtained from 12-lead ECGs before pacemaker implantation in MOST, a 2010-patient, 6-year, randomized trial of DDDR versus VVIR pacing in SND. Cumulative percent ventricular paced (Cum%VP) was determined from stored pacemaker data. Baseline QRSd <120 ms was observed in 1339 patients (707 DDDR, 632 VVIR). Cum%VP was greater in DDDR versus VVIR (90% versus 58%, P =0.001). Cox models demonstrated that the time-dependent covariate Cum%VP was a strong predictor of HF hospitalization in DDDR (hazard ratio [HR], 2.99 [95% CI, 1.15 to 7.75] for Cum%VP >40%) and VVIR (HR 2.56 [95% CI, 1.48 to 4.43] for Cum%VP >80%). The risk of AF increased linearly with Cum%VP from 0% to 85% in both groups (DDDR, HR 1.36 [95% CI, 1.09, 1.69]; VVIR, HR 1.21 [95% CI 1.02, 1.43], for each 25% increase in Cum%VP). Model results were unaffected by adjustment for known baseline predictors of HF hospitalization and AF. Conclusions— Ventricular desynchronization imposed by ventricular pacing even when AV synchrony is preserved increases the risk of HF hospitalization and AF in SND with normal baseline QRSd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In patients with intact AV conduction, programming should try to minimize ventricular pacing due to the risks of heart failure and atrial fibrillation with higher rates of unnecessary ventricular pacing, as well as greater current drain on the pacemaker battery [13] .”
From Evaluating and managing bradycardia (2020) · cites this paper as [13]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,236
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Modeling Survival Data: Extending the Cox Model
Therneau, T. M., & Grambsch, P. M. (2000) · Statistics for Biology and Health · doi:10.1007/978-1-4757-3294-8 · Cited by 8,674
Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., León, A. R., Yee, R. K., Marinchak, R. A., Flaker, G., SCHRON, E. B., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 995
Self-citationAndersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 638
Self-citationAsynchronous Electrical Activation Induces Asymmetrical Hypertrophy of the Left Ventricular Wall
van Oosterhout, M. F. M., Prinzen, F. W., Arts, T. G. J., Schreuder, J. J., Vanagt, W. Y. R., Cleutjens, J. P. M., & Reneman, R. S. (1998) · Circulation · doi:10.1161/01.cir.98.6.588 · Cited by 363
Cited by
Sorted by citations
Items 201–300 of 1,000
Vlay, S. C. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00498.x · Cited by 61
Linde, C. M., Normand, C., Bogale, N., Auricchio, A., Sterlinski, M. M., Marinskis, G., Sticherling, C., Bulava, A., Pérez, Ó. C., Maass, A. H., et al. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.1235 · Cited by 62
A New Dual‐Chamber Pacing Mode to Minimize Ventricular Pacing
Savouré, A., Fröhlig, G., Galley, D., Defaye, P., Reuter, S., Mabo, P., Sadoul, N., Amblard, A., LIMOUSIN, M., & Anselme, F. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00095.x · Cited by 61
Impact of Right Ventricular Pacing in Patients With TAVR Undergoing Permanent Pacemaker Implantation
Bruno, F., Pousa, I. M., Saia, F., Vaira, M. P., Baldi, E., Leone, P. P., Cabanas‐Grandío, P., Corcione, N., Spinoni, E. G., Annibali, G., et al. (2023) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2023.02.003 · Cited by 60
His and para-His pacing in AV block: feasibility and electrocardiographic findings
Kronborg, M. B., Mortensen, P. T., Gerdes, J. C., Jensen, H. K., & Nielsen, J. C. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9565-1 · Cited by 60
Mechano-energetics of the asynchronous and resynchronized heart
Prinzen, F. W., Vernooy, K., DeBoeck, B. W. L., & Delhaas, T. (2010) · Heart Failure Reviews · doi:10.1007/s10741-010-9205-3 · Cited by 60
Lau, C., Ngarmukos, T., Wang, C., Wang, J.-F., Abe, H., Kong, C., Liew, R., Shin, D., Padeletti, L., Kim, Y., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.001644 · Cited by 60
Cardiac memory: Mechanisms and clinical implications
Patberg, K. W., Shvilkin, A. V., Plotnikov, A. N., Chandra, P., Josephson, M. E., & Rosen, M. R. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.08.021 · Cited by 60
Current Concepts of Premature Ventricular Contractions.
Ahn, M. (2013) · Europe PMC (PubMed Central) · Cited by 60
Mohananey, D., Jobanputra, Y. B., Kumar, A., Krishnaswamy, A., Mick, S., White, J., & Kapadia, S. R. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.117.005046 · Cited by 60
His Bundle Pacing: A New Frontier in the Treatment of Heart Failure
Ali, N., Keene, D., Arnold, A. D., Shun-Shin, M. J., Whinnett, Z. I., & Sohaib, S. A. (2018) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2018.6.2 · Cited by 61
Abnormal Conduction Increases Risk of Adverse Outcomes From Right Ventricular Pacing
Hayes, J. J., Sharma, A. D., Love, J. C., Herre, J. M., Leonen, A. O., & Kudenchuk, P. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.071 · Cited by 60
Pooter, J. D., Özpak, E., Calle, S., Peytchev, P., Heggermont, W., Marchandise, S., Provenier, F., François, B., Anné, W., Pollet, P., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15558 · Cited by 59
Chung, M. K., Patton, K. K., Lau, C., Forno, A. D., Al‐Khatib, S. M., Arora, V., Birgersdotter-Green, U. M., Cha, Y., Chung, E. H., Cronin, E. M., et al. (2023) · Journal of Arrhythmia · doi:10.1002/joa3.12872 · Cited by 59
Self-citationCurtis, A. B., Adamson, P. B., Chung, E. S., Sutton, M. S. J., Tang, F. R., & WORLEY, S. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00907.x · Cited by 59
Riahi, S., Nielsen, J. C., Hjortshøj, S. P., Thomsen, P. E. B., Højberg, S., Møller, M., Dalsgaard, D., Nielsen, T., Asklund, M., Friis, E. V., et al. (2012) · EP Europace · doi:10.1093/europace/eus069 · Cited by 58
Gold, M. R., Adler, S. W., Fauchier, L., Haffajee, C. I., Ip, J. E., Kainz, W., Kawasaki, R., Prakash, A., Táborský, M., Waller, T., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.11.033 · Cited by 58
Merchant, F. M., & Mittal, S. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2018.05.005 · Cited by 58
Chen, S., Chau, K. H.-Y., & Nazif, T. M. (2020) · Annals of Cardiothoracic Surgery · doi:10.21037/acs-2020-av-23 · Cited by 57
Li, X., Zhang, J., Qiu, C., Wang, Z., Li, H., Pang, K., Yao, Y., Liu, Z., Xie, R., Chen, Y., et al. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.685253 · Cited by 57
Atrial overdrive pacing to prevent atrial fibrillation: Insights from ASSERT
Hohnloser, S. H., Healey, J. S., Gold, M. R., Israel, C. W., Yang, S., Gelder, I. C. V., Capucci, A., Lau, C., Fain, E. S., Morillo, C. A., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.06.012 · Cited by 57
Heart failure due to right ventricular apical pacing: the importance of flow patterns
Cicchitti, V., Radico, F., Bianco, F., Gallina, S., Tonti, G., & Caterina, R. D. (2016) · EP Europace · doi:10.1093/europace/euw024 · Cited by 57
Rinfret, S., Cohen, D. J., Lamas, G. A., Fleischmann, K. E., Weinstein, M. C., Orav, E. J., SCHRON, E. B., Lee, K. L., & Goldman, L. (2005) · Circulation · doi:10.1161/01.cir.0000151810.69732.41 · Cited by 57
Self-citationJCS/JHRS 2024 Guideline Focused Update on Management of Cardiac Arrhythmias
Iwasaki, Y., Noda, T., Akao, M., Fujino, T., Hirano, T., Inoue, K., KUSANO, K. F., Nagai, T., Satomi, K., Shinohara, T., et al. (2025) · Circulation Journal · doi:10.1253/circj.cj-24-0073 · Cited by 57
Should β-Blockers Be Used in Patients With Heart Failure and Atrial Fibrillation?
Mareev, Y. V., & Cleland, J. G. F. (2015) · Clinical Therapeutics · doi:10.1016/j.clinthera.2015.08.017 · Cited by 56
Gage, R. M., Burns, K. V., & Bank, A. J. (2014) · European Journal of Heart Failure · doi:10.1002/ejhf.143 · Cited by 56
Smit, M. D., van Dessel, P. F. H. M., Nieuwland, W., Wiesfeld, A. C. P., Tan, E. S., Anthonio, R. L., van Erven, L., van Veldhuisen, D. J., & Gelder, I. C. V. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.08.006 · Cited by 56
Camm, A. J., Sulke, N., Edvardsson, N. G., Ritter, P., Albers, B., RUITER, J. H., Lewalter, T., Capucci, P., Hoffmann, E., & on behalf of the AFTherapy investigators (2007) · EP Europace · doi:10.1093/europace/eum253 · Cited by 56
Ebert, M., Jander, N., Minners, J., Blum, T., Doering, M., Bollmann, A., Hindricks, G., Arentz, T., Kalusche, D., & Richter, S. (2016) · Journal of the American Heart Association · doi:10.1161/jaha.116.003485 · Cited by 56
Shurrab, M., Healey, J. S., Haj‐Yahia, S., Kaoutskaia, A., Boriani, G., Carrizo, A. G., Botto, G., Newman, D. M., Padeletti, L., Connolly, S. J., et al. (2016) · EP Europace · doi:10.1093/europace/euw221 · Cited by 56
Mechanisms and Clinical Significance of Arrhythmia-Induced Cardiomyopathy
Raymond-Paquin, A., Nattel, S., Wakili, R., & Tadros, R. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.07.475 · Cited by 56
Kosztin, A., Vámos, M., Aradi, D., Schwertner, W. R., Kovács, A. D., Nagy, K. V., Zima, E., Gellér, L., Duray, G. Z., Kutyifa, V., et al. (2017) · Heart Failure Reviews · doi:10.1007/s10741-017-9652-1 · Cited by 55
A 20-year journey in transcatheter aortic valve implantation: Evolution to current eminence
Kalogeropoulos, A. S., Redwood, S. R., Allen, C. J., Hurrell, H., Chehab, O., Rajani, R., Prendergast, B., & Patterson, T. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.971762 · Cited by 54
Schmidt, M. U., Brömsen, J., Herholz, C., Adler, K., Neff, F., Kopf, C., & Block, M. S. (2007) · EP Europace · doi:10.1093/europace/eul131 · Cited by 55
Sutureless Aortic Valve and Pacemaker Rate: From Surgical Tricks to Clinical Outcomes
Vogt, F. A., Moscarelli, M., Nicoletti, A., Gregorini, R., Pollari, F., Kalisnik, J. M., Pfeiffer, S., Fischlein, T. J. M., & Santarpino, G. (2019) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2018.12.037 · Cited by 55
Čurila, K., Procházková, R., Jurák, P., Jastrzębski, M., Halámek, J., Moskal, P., Štros, P., Veselá, J., Waldauf, P., Viščor, I., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.11.016 · Cited by 54
Sinus node dysfunction: current understanding and future directions
Manoj, P., Kim, J. A., Kim, S. J., Li, T., Sewani, M. A., Chelu, M. G., & Li, N. (2022) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00618.2022 · Cited by 53
Molina, L. G., Sutton, R., GANDOY, W., Reyes, N. R., Lara, S., Limón, F., GÓMEZ, S., Orihuela, C., Salame, L., & MORENO, G. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12257 · Cited by 53
Gebauer, R., Tomek, V., Kubuš, P., Rázek, V., Matějka, T., Salameh, A., Kostelka, M., & Janoušek, J. (2009) · EP Europace · doi:10.1093/europace/eup342 · Cited by 53
Advanced ICD Troubleshooting: Part II
Swerdlow, C. D., & Friedman, P. A. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00300.x · Cited by 53
Thresholds and Complications with Right Ventricular Septal Pacing Compared to Apical Pacing
Burri, H., Sunthorn, H., Dorsaz, P. ‐., VIERA, I., & Shah, D. C. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00610.x · Cited by 52
Veasey, R. A., Arya, A., Silberbauer, J., Sharma, V., Lloyd, G., Patel, N., & Sulke, A. N. (2011) · EP Europace · doi:10.1093/europace/euq463 · Cited by 52
Permanent His Bundle Pacing: The Past, Present, and Future
Sharma, P. S., Ellenbogen, K. A., & Trohman, R. G. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13154 · Cited by 52
Self-citationApproach to permanent His bundle pacing in challenging implants
Vijayaraman, P., & Ellenbogen, K. A. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.03.006 · Cited by 52
Self-citationGong, X., Su, Y., Pan, W., Cui, J., Liu, S., & Shu, X. (2009) · Clinical Cardiology · doi:10.1002/clc.20677 · Cited by 51
Diretriz Brasileira de Dispositivos Cardíacos Eletrônicos Implantáveis – 2023
Teixeira, R. A., Fagundes, A. A., Baggio, J. M., de Oliveira, J. C., Medeiros, P. D. T. J., Valdigem, B. P., Teno, L. A. C., Silva, R. T., de Melo, C. S., Elías, J., et al. (2023) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20220892 · Cited by 53
Önalan, O., Crystal, A., Lashevsky, I., Khalameizer, V., Lau, C., Goldman, B. S., Fremes, S. E., Newman, D. M., Lukomsky, M., & Crystal, E. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2007.07.062 · Cited by 50
Fang, F., Zhang, Q., Chan, J. Y., Omar, R., Hussin, A., Chan, H. C.-K., Sanderson, J. E., Xie, J., & Yu, C. (2012) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.08.005 · Cited by 49
Slotwiner, D. J., Raitt, M. H., Del-Carpio Munoz, F., Mulpuru, S. K., Nasser, N., & Peterson, P. N. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.035 · Cited by 49
Nikolaidou, T., GHOSH, J. M., & Clark, A. L. (2016) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2016.02.012 · Cited by 49
Pacing therapy for prevention of atrial fibrillation
Ellenbogen, K. A. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.005 · Cited by 49
Self-citationMerkely, B. P., Kosztin, A., Róka, A., Gellér, L., Zima, E., Kovács, A. D., Boros, A. M., Klein, H., Wranicz, J. K., Hindricks, G., et al. (2016) · EP Europace · doi:10.1093/europace/euw193 · Cited by 48
Slotwiner, D. J., Raitt, M. H., Munoz, F. D., Mulpuru, S. K., Nasser, N. H., & Peterson, P. N. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.045 · Cited by 48
Shimano, M., Tsuji, Y., Yoshida, Y., Inden, Y., Tsuboi, N., Itoh, T., Suzuki, H., Muramatsu, T., Okada, T., Harata, S., et al. (2007) · EP Europace · doi:10.1093/europace/eum119 · Cited by 48
Burri, H., Park, C.-I., Zimmermann, M., Gentil-Baron, P., Stettler, C., Sunthorn, H., Domenichini, G., & Shah, D. (2010) · EP Europace · doi:10.1093/europace/euq332 · Cited by 48
Elkayam, L. U., Koehler, J. L., Sheldon, T., Glotzer, T. V., ROSENTHAL, L. S., & Lamas, G. A. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03192.x · Cited by 47
Self-citationSze, E. Y., Dunning, A. L., Loring, Z., Atwater, B. D., Chiswell, K., Daubert, J. P., KISSLO, J. A., Mark, D. B., Velazquez, E. J., & Samad, Z. Z. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.08.003 · Cited by 47
Relation Between Abnormal Ventricular Impulse Conduction and Heart Failure
Vernooy, K., Verbeek, X. A. A. M., Peschar, M., & Prinzen, F. W. (2003) · Journal of Interventional Cardiology · doi:10.1046/j.1540-8183.2003.01061.x · Cited by 47
Interventional Electrophysiology and Cardiac Resynchronization Therapy
Burkhardt, J. D., & Wilkoff, B. L. (2007) · Circulation · doi:10.1161/circulationaha.106.655712 · Cited by 47
Vijayaraman, P., Dandamudi, G., Lustgarten, D. L., & Ellenbogen, K. A. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13130 · Cited by 46
Self-citationSafety and feasibility of a midseptal implantation technique of a leadless pacemaker
Hai, J. J., Fang, J. X., Tam, C. C., Wong, C., Un, K., Siu, C., Lau, C., & Tse, H. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.12.007 · Cited by 46
Resynchronizing Ventricular Contraction in Heart Failure
Jarcho, J. A. (2005) · New England Journal of Medicine · doi:10.1056/nejme058065 · Cited by 46
Lau, D. H., Psaltis, P. J., Mackenzie, L., Kelly, D. J., Carbone, A., Worthington, M. G., Nelson, A. J., ZHANG, Y., Kuklik, P., Wong, C. X. J., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01851.x · Cited by 45
Paparella, G., Sciarra, L., Capulzini, L., FRANCESCONI, A., de Asmundis, C., Sarkozy, A., CAZZIN, R., & Brugada, P. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02701.x · Cited by 45
Botto, G. L., Ricci, R. P., Bénézet, J. M., Nielsen, J. C., Roy, L. D., Piot, O., Quesada, A., Quaglione, R., Vaccari, D., Garutti, C., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.01.011 · Cited by 45
Contemporary Pacemaker and Defibrillator Device Therapy
Schoenfeld, M. H. (2007) · Circulation · doi:10.1161/circulationaha.106.618587 · Cited by 45
Sapp, J. L., Parkash, R., Wells, G. A., Yetisir, E., Gardner, M. J., Healey, J. S., Thibault, B., Sterns, L. D., Birnie, D. H., Nery, P. B., et al. (2017) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004875 · Cited by 45
Vijayaraman, P., Subzposh, F. A., & Naperkowski, A. M. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.06.005 · Cited by 45
Murakami, Y., Tsuboi, N., Inden, Y., Yoshida, Y., Murohara, T., Ihara, Z., & Takami, M. (2009) · EP Europace · doi:10.1093/europace/eup252 · Cited by 45
Wilkoff, B. L., Fauchier, L., Stiles, M. K., Morillo, C. A., Al‐Khatib, S. M., Almendral, J., Aguinaga, L., Berger, R. D., Cuesta, A., Daubert, J. P., et al. (2016) · Journal of Arrhythmia · doi:10.1016/j.joa.2015.12.001 · Cited by 44
Self-citationOlshansky, B., Day, J. D., Lerew, D. R., Brown, S., & Stolen, K. Q. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.03.031 · Cited by 44
Albertsen, A. E., Mortensen, P. T., Jensen, H. K., Poulsen, S. H., Egeblad, H., & Nielsen, J. C. (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jer136 · Cited by 44
Garweg, C., Vandenberk, B., Foulon, S., Haemers, P., Ector, J., & Willems, R. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14083 · Cited by 44
Slotwiner, D. J., Raitt, M. H., Munoz, F. D., Mulpuru, S. K., Nasser, N. H., & Peterson, P. N. (2019) · Circulation · doi:10.1161/cir.0000000000000629 · Cited by 45
Lustgarten, D. L., Habel, N., Sánchez‐Quintana, D., Winget, J. F., de Sa, D. C., Lobel, R. M., Thompson, N. C., Infeld, M. M., & Meyer, M. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.1786 · Cited by 43
Sweeney, M. O., Ellenbogen, K. A., Tang, A., Johnson, J. W., Belk, P. A., & Sheldon, T. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01226.x · Cited by 43
Self-citationAhmed, F. Z., Motwani, M., Cunnington, C., Kwok, C. S., Fullwood, C., Oceandy, D., Fitchet, A., Goode, G., Luckie, M., Zaidi, A. M., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0162072 · Cited by 43
Wang, Z., Zhu, H., Li, X., Yao, Y., Liu, Z., & Fan, X. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.695531 · Cited by 43
Ravi, V., Beer, D. A., Pietrasik, G. M., Hanifin, J. L., Ooms, S., Ayub, M. T., Larsen, T. R., Huang, H. D., Krishnan, K., Trohman, R. G., et al. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.120.018478 · Cited by 42
Pacemaker Induced Cardiomyopathy: An Overview of Current Literature
Gavaghan, C. (2021) · Current Cardiology Reviews · doi:10.2174/2772432816666210901111616 · Cited by 42
Jastrzębski, M., Kiełbasa, G., Cano, Ó., Čurila, K., Zanon, F., Pestrea, C., Pooter, J. D., LUERMANS, J. G. L. M., Rademakers, L. M., Žižek, D., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf699 · Cited by 42
Xie, J., Fang, F., Zhang, Q., Chan, J. Y., Yip, G. W., Sanderson, J. E., Lam, Y., Yan, B. P., & Yu, C. (2011) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.12.075 · Cited by 42
Right Ventricular Outflow Tract Septal Pacing: Long‐Term Follow‐Up of Ventricular Lead Performance
MEDI, C., & Mond, H. G. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02199.x · Cited by 42
The Road to Right Ventricular Septal Pacing: Techniques and Tools
Mond, H. G. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02777.x · Cited by 42
Apical vs. non-apical right ventricular pacing in cardiac resynchronization therapy: a meta-analysis
Zografos, T. A., Siontis, K. C., Jastrzębski, M., Kutyifa, V., Klein, H., Zaręba, W., & Katritsis, D. G. (2015) · EP Europace · doi:10.1093/europace/euv048 · Cited by 44
Comparison of Two Strategies to Reduce Ventricular Pacing in Pacemaker Patients
Pürerfellner, H., Brandt, J., Israel, C. W., Sheldon, T., Johnson, J. W., Tscheliessnigg, K., Sperzel, J., Boriani, G., PUGLISI, A., & Milašinović, G. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00965.x · Cited by 42
Occhetta, E., Bortnik, M., & Marino, P. N. (2007) · PubMed Central · Cited by 42
Nadeem, F., Tsushima, T., Ladas, T. P., Thomas, R., Patel, S. M., Saric, P., Patel, T. R., Lipinski, J., Li, J., Costa, M. A., et al. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.07.046 · Cited by 42
Pacing for hypertrophic obstructive cardiomyopathy: an update and future directions
Daubert, J., Gadler, F., Mabo, P., & Linde, C. M. (2017) · EP Europace · doi:10.1093/europace/eux131 · Cited by 41
Chow, C., Wong, C. Y., Sutherland, N., Obeyesekere, M., Wong, G. R., Eastwood, C. M., Abduloska, J., Davey, C. M., Bhutani, A. S., Tran, V., et al. (2025) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2025.06.043 · Cited by 41
Vavasis, C., Slotwiner, D. J., Goldner, B. G., & Cheung, J. W. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02655.x · Cited by 41
ADELSTEIN, E. C., SCHWARTZMAN, D. S., Gorcsan, J., & Saba, S. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02018.x · Cited by 41
Hu, Y., Li, H., Gu, M., Hua, W., Niu, H., Zhang, N., Liu, X., Chen, X., Hou, C., Zhou, X., et al. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00869-w · Cited by 41
Zhang, S., Guo, J., Tao, A., Zhang, B., Bao, Z.-H., & Zhang, G. (2021) · Clinical Cardiology · doi:10.1002/clc.23513 · Cited by 41
Pacing induced cardiomyopathy: recognition and management
Ponnusamy, S. S., Syed, T., & Vijayaraman, P. (2023) · Heart · doi:10.1136/heartjnl-2022-321723 · Cited by 40
Cardiac Resynchronization Therapy in Patients with Right Ventricular Pacing-Induced Cardiomyopathy
Nazeri, A., Massumi, A., Rasekh, A., Saeed, M., Frank, C. J., & Razavi, M. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02594.x · Cited by 40
Mulpuru, S. K., Cha, Y., & Asirvatham, S. J. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.08.005 · Cited by 40
Right Ventricular Septal Pacing: The Success of Stylet-Driven Active-Fixation Leads
Rosso, R., Teh, A. W., MEDI, C., HUNG, T. T., Balasubramaniam, R., & Mond, H. G. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02580.x · Cited by 40
Vijayaraman, P., Longacre, C. F., Kron, J., Subzposh, F. A., Zimmerman, P., Butler, K., Crossley, G. H., & Ellenbogen, K. A. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.08.052 · Cited by 39
Self-citationWhy and How do Elderly Patients with Heart Failure Die? Insights from the TIME-CHF Study
Rickenbacher, P. R., Pfisterer, M. E., Burkard, T., Kiowski, W., Folláth, F., BURCKHARDT, D., Schindler, R., Rocca, H. B., & for the TIME-CHF Investigators (2012) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfs113 · Cited by 39
Metadata
- Authors
- Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A.
- Affiliations
- Brigham and Women's Hospital (US)
- Corresponding author
- Sweeney, Michael O.
- ORCID
- Venue
- Circulation
- Published
- 2003-06-17
- Volume
- 107
- Issue
- 23
- Pages
- 2932-2937
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1992880616
- Semantic Scholar
- f64ee53940d6857ca50be244f1edf56583485f93
- Cited by
- 1,773
- References
- 22
- Citations by year
- 2026: 63 · 2025: 87 · 2024: 79 · 2023: 109 · 2022: 79 · 2021: 94 · 2020: 80 · 2019: 68 · 2018: 82 · 2017: 74 · 2016: 71 · 2015: 70 · 2014: 69 · 2013: 66 · 2012: 75
- FWCI
- 46.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5u01hl053973-05)
- National Heart, Lung, and Blood Institute (U01HL049804, U01 HL 53973, U01-HL-49804)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- ventricular pacing, sick sinus syndrome, heart failure hospitalization, atrial fibrillation, DDD pacing, QRS duration, pacemaker therapy
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Bradycardia, Cardiac Pacing, Artificial, Electrocardiography, Female, Follow-Up Studies, Heart Failure, Hospitalization, Humans, Male, Sick Sinus Syndrome, Proportional Hazards Models, Survival Analysis, Randomized Controlled Trials as Topic, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review