The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node Dysfunction
Abstract
Background— Dual-chamber (DDDR) pacing preserves AV synchrony and may reduce heart failure (HF) and atrial fibrillation (AF) compared with ventricular (VVIR) pacing in sinus node dysfunction (SND). However, DDDR pacing often results in prolonged QRS durations (QRSd) as the result of right ventricular stimulation, and ventricular desynchronization may result. The effect of pacing-induced ventricular desynchronization in patients with normal baseline QRSd is unknown. Methods and Results— Baseline QRSd was obtained from 12-lead ECGs before pacemaker implantation in MOST, a 2010-patient, 6-year, randomized trial of DDDR versus VVIR pacing in SND. Cumulative percent ventricular paced (Cum%VP) was determined from stored pacemaker data. Baseline QRSd <120 ms was observed in 1339 patients (707 DDDR, 632 VVIR). Cum%VP was greater in DDDR versus VVIR (90% versus 58%, P =0.001). Cox models demonstrated that the time-dependent covariate Cum%VP was a strong predictor of HF hospitalization in DDDR (hazard ratio [HR], 2.99 [95% CI, 1.15 to 7.75] for Cum%VP >40%) and VVIR (HR 2.56 [95% CI, 1.48 to 4.43] for Cum%VP >80%). The risk of AF increased linearly with Cum%VP from 0% to 85% in both groups (DDDR, HR 1.36 [95% CI, 1.09, 1.69]; VVIR, HR 1.21 [95% CI 1.02, 1.43], for each 25% increase in Cum%VP). Model results were unaffected by adjustment for known baseline predictors of HF hospitalization and AF. Conclusions— Ventricular desynchronization imposed by ventricular pacing even when AV synchrony is preserved increases the risk of HF hospitalization and AF in SND with normal baseline QRSd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In patients with intact AV conduction, programming should try to minimize ventricular pacing due to the risks of heart failure and atrial fibrillation with higher rates of unnecessary ventricular pacing, as well as greater current drain on the pacemaker battery [13] .”
From Evaluating and managing bradycardia (2020) · cites this paper as [13]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,236
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Modeling Survival Data: Extending the Cox Model
Therneau, T. M., & Grambsch, P. M. (2000) · Statistics for Biology and Health · doi:10.1007/978-1-4757-3294-8 · Cited by 8,674
Ventricular Pacing or Dual-Chamber Pacing for Sinus-Node Dysfunction
Lamas, G. A., Lee, K. L., Sweeney, M. O., Silverman, R., León, A. R., Yee, R. K., Marinchak, R. A., Flaker, G., SCHRON, E. B., Orav, E. J., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013040 · Cited by 995
Self-citationAndersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421902 · Cited by 775
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 638
Self-citationAsynchronous Electrical Activation Induces Asymmetrical Hypertrophy of the Left Ventricular Wall
van Oosterhout, M. F. M., Prinzen, F. W., Arts, T. G. J., Schreuder, J. J., Vanagt, W. Y. R., Cleutjens, J. P. M., & Reneman, R. S. (1998) · Circulation · doi:10.1161/01.cir.98.6.588 · Cited by 363
Cited by
Sorted by citations
Items 401–500 of 1,000
Right Ventricular Pacing, Mechanical Dyssynchrony, and Heart Failure
Bank, A. J., Gage, R., & Burns, K. V. (2011) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-011-9341-8 · Cited by 27
The importance of avoiding unnecessary right ventricular pacing in clinical practice
Akerström, F. O. (2013) · World Journal of Cardiology · doi:10.4330/wjc.v5.i11.410 · Cited by 27
Atrial Fibrillation and Heart Failure: Untangling a Modern Gordian Knot
Skanes, A. C., & TANG, A. S. L. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.07.483 · Cited by 27
Kodama, Y., Kuraoka, A., Ishikawa, Y., Nakamura, M., Ushinohama, H., Sagawa, K., Umemoto, S., Hashimoto, T., Sakamoto, I., Ohtani, K., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.06.019 · Cited by 27
Adopting permanent His bundle pacing: learning curves and medium-term outcomes
de Leon, J., Seow, S., Boey, E., Soh, R. Y.-H., Tan, E. S. J., Gan, H. H., Lee, J. Y., Teo, L. J. T., Yeo, C., Tan, V. H., et al. (2021) · EP Europace · doi:10.1093/europace/euab278 · Cited by 27
The response to cardiac resynchronization therapy in LMNA cardiomyopathy
Sidhu, K., Castrini, A. I., Parikh, V. N., Reza, N., OWENS, A. T., Tremblay‐Gravel, M., Wheeler, M. T., Mestroni, L., Taylor, M. R. G., Graw, S. L., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2463 · Cited by 27
Pacemaker Syndrome During Managed Ventricular Pacing Mode: What is the Mechanism?
Pascale, P., Pruvot, E. J., & Graf, D. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01398.x · Cited by 27
FUNCK, R. C., Boriani, G., Manolis, A. S., Püererfellner, H., Mont, L., Tukkie, R., Pisapia, A., Israel, C. W., Grovale, N., Grammatico, A., et al. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.05.004 · Cited by 27
Bulava, A., & LUKL, J. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.02224.x · Cited by 27
Burns, K. V., Gage, R. M., Curtin, A. E., Gorcsan, J., & Bank, A. J. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.906 · Cited by 27
Sharma, E., McCauley, B. D., Ghosalkar, D. S., Atalay, M. K., Collins, S., Parulkar, A. B., Sheikh, W., Ahmed, M. B., & Chu, A. F. (2020) · Cardiology Research · doi:10.14740/cr1011 · Cited by 27
Managed Ventricular Pacing in Pediatric Patients and Patients With Congenital Heart Disease
Kaltman, J. R., Ro, P. S., Zimmerman, F. J., Moak, J. P., Epstein, M. L., Zeltser, I., Shah, M. J., Buck, K., Vetter, V. L., & Tanel, R. E. (2008) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.05.028 · Cited by 27
Ichiki, H., Oketani, N., Hamasaki, S., Ishida, S., Kataoka, T., Ogawa, M., Saihara, K., Okui, H., Fukudome, T., SHINASATO, T., et al. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00474.x · Cited by 27
Kutalek, S. P., Sharma, A. D., McWilliams, M. J., Wilkoff, B. L., Leonen, A. O., Hallstrom, A. P., Kudenchuk, P. J., & the DAVID Investigators (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01106.x · Cited by 26
Witt, C. M., Lenz, C. J., Shih, H., Ebrille, E., Rosenbaum, A. N., van Zyl, M., Aung, H., Manocha, K. K., Deshmukh, A. J., Hodge, D. O., et al. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13256 · Cited by 26
Novel bradycardia pacing strategies
Heckman, L. I. B., Vijayaraman, P., LUERMANS, J. G. L. M., van Stipdonk, A. M. W., Salden, F., Maass, A. H., Prinzen, F. W., & Vernooy, K. (2020) · Heart · doi:10.1136/heartjnl-2020-316849 · Cited by 26
Niu, H., Liu, X., Gu, M., Chen, X., Cai, C., Cai, M., Zhang, S., & Hua, W. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.772548 · Cited by 26
Guía ESC 2021 sobre estimulación cardiaca y terapia de resincronización
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · Revista Española de Cardiología · doi:10.1016/j.recesp.2021.10.025 · Cited by 28
Rijks, J. H. J., Lankveld, T., Manusama, R., Broers, B., van Stipdonk, A. M. W., Chaldoupi, S., ter Bekke, R. M. A., Schotten, U., Linz, D., LUERMANS, J. G. L. M., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12124028 · Cited by 26
Conduction system pacing: overview, definitions, and nomenclature
Jastrzębski, M., Dandamudi, G., Burri, H., & Ellenbogen, K. A. (2023) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suad114 · Cited by 26
Self-citationConduction System Stimulation to Avoid Left Ventricle Dysfunction
González-Matos, C. E., Rodríguez-Queraltó, O., Záraket, F., Jiménez-López, J. I., Casteigt, B. J., & Vallès, E. (2024) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.123.012473 · Cited by 26
Kolb, C., Schmidt, R., DIETL, J. U., Weyerbrock, S., Morgenstern, M., FLECKENSTEIN, M., BEIER, T., von Bary, C., Mackes, K. G., WIDMAIER, J., et al. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03075.x · Cited by 26
Engineered Electrical Conduction Tract Restores Conduction in Complete Heart Block
Cingolani, E., Ionta, V., Cheng, K., Giacomello, A., Cho, H. C., & Marbán, E. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.056 · Cited by 26
Francia, P., Balla, C., Uccellini, A., & Cappato, R. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01477.x · Cited by 26
The role of pacing mode in the development of atrial fibrillation
Israel, C. W. (2006) · EP Europace · doi:10.1093/europace/euj038 · Cited by 26
Choudhury, M., Black, N., Alghamdi, A., D’Souza, A., Wang, R., Yanni, J., Dobrzynski, H., Kingston, P. A., Zhang, H., Boyett, M. R., et al. (2018) · The Journal of Physiology · doi:10.1113/jp276508 · Cited by 26
Ovsyshcher, I. E., & Barold, S. S. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00597.x · Cited by 26
Selective site ventricular pacing
McGavigan, A. D., & Mond, H. G. (2005) · Current Opinion in Cardiology · doi:10.1097/01.hco.0000198981.48013.70 · Cited by 26
Predictors and 5-Year Clinical Outcomes of Pacemaker After TAVR
Chen, S., Dizon, J. M., Hahn, R. T., Pîbarot, P., George, I., Zhao, Y., Blanke, P., Kapadia, S. R., Babaliaros, V. C., Szeto, W. Y., et al. (2024) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2024.03.034 · Cited by 25
Physiological pacing: mechanisms, clinical indications, and perspectives
Whinnett, Z. I., Naraen, A., Vijayaraman, P., Cleland, J. G. F., & Keene, D. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf440 · Cited by 25
The Downside of Right Ventricular Apical Pacing
brenyo, A. J., Goldenberg, I., & Barsheshet, A. (2012) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30502-2 · Cited by 25
Yang, Y., Wang, K., Ma, P., Zhang, R., Waleed, K. B., Yin, X., Gao, L., Xia, Y., & Dong, Y. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.04.012 · Cited by 25
Tsushima, T., Al-Kindi, S. G., Dallan, L. A. P., Fares, A., Yoon, S., Wheat, H., Attizzani, G. F., Baeza, C. R., Pelletier, M. P., Arruda, M. S., et al. (2023) · EP Europace · doi:10.1093/europace/euad025 · Cited by 25
Cardiac Pacing Induced Cardiomyopathy: Mith or Reality Sustained by Evidence?
Ferrari, A. D. L., Borges, A. P., Albuquerque, L. C., Süssenbach, C. P., da Rosa, P. R., Piantá, R. M., Wiehe, M., & Goldani, M. A. (2014) · Brazilian Journal of Cardiovascular Surgery · doi:10.5935/1678-9741.20140104 · Cited by 25
PARK, Y., Kim, S., Shin, J.-W., OH, A. R., SHIN, E. J., Lee, J. H., Ahn, T., Cha, J.-Y., & Moon, J. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12447 · Cited by 25
Acute and Chronic Response to CRT in Narrow QRS Patients
on behalf of the ESTEEM-CRT Investigators, Donahue, T., Niazi, I. K., León, A. R., Stucky, M. J., & Herrmann, K. L. (2011) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-011-9338-3 · Cited by 25
AAIsafeR Limits Ventricular Pacing in Unselected Patients
PIOGER, G., LENY, G., Nitzsché, R., & Ripart, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00608.x · Cited by 25
Raelson, C. A., Gabriels, J. K., Ruan, J., Ip, J. E., Thomas, G., Liu, C. F., Cheung, J. W., Lerman, B. B., Patel, A., & Markowitz, S. M. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13291 · Cited by 25
Miyazawa, K., Pastori, D., Li, Y., Székely, O., Shahid, F., Boriani, G., & Lip, G. Y. H. (2019) · Clinical Research in Cardiology · doi:10.1007/s00392-019-01432-y · Cited by 25
Riva, S. I. (1999) · EP Europace · doi:10.1053/eupc.1999.0048 · Cited by 25
FUNCK, R. C., Müller, H., Lunati, M., Roy, L. D., Klein, N., Meisel, E., Milašinović, G., Carlson, M. D., Wittenberg, M., Hindricks, G., et al. (2025) · EP Europace · doi:10.1093/europace/euaf029 · Cited by 24
Effects of right ventricular septal versus apical pacing on plasma natriuretic peptide levels
Nikoo, M. H., Ghaedian, M. M., Kafi, M., Jorat, M. V., Fakhrpour, A., Pakfetrat, M., Ostovan, M. A., & Emkanjoo, Z. (2011) · Journal of Cardiovascular Disease Research · doi:10.4103/0975-3583.83036 · Cited by 24
Ludwig, D. R., Tanaka, H., Friehling, M. S., Gorcsan, J., & SCHWARTZMAN, D. S. (2013) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-013-9457-0 · Cited by 24
Chen, S., Chen, K., Tao, Q.-M., Zheng, L., Shen, F., Wu, S., Fan, J., Xu, G., Wang, L., Zhou, X., et al. (2014) · EP Europace · doi:10.1093/europace/euu055 · Cited by 24
Permanent His Bundle Pacing in Patients With Congenital Complete Heart Block
Dandamudi, G., Simon, J. W., Cano, Ó., Master, V. M., Koruth, J. S., Naperkowski, A. M., Kean, A. C., Schaller, R. D., Ellenbogen, K. A., Kron, J., et al. (2020) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2020.09.015 · Cited by 24
Self-citationEvolutionary innovations in cardiac pacing
Cheng, A., & Tereshchenko, L. G. (2011) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2011.07.021 · Cited by 24
Pacemaker troubleshooting: When MVP is not the most valuable parameter
Mansour, F., Talajic, M. R., Thibault, B., & Khairy, P. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2005.12.028 · Cited by 24
Rosanio, S., Schwarz, E. R., Ahmad, M., Jammula, P., Vitarelli, A., Uretsky, B. F., Birnbaum, Y., Ware, D. L., Atar, S., & Saeed, M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.04.050 · Cited by 24
Right or Left Ventricular Pacing in Young Minipigs With Chronic Atrioventricular Block
Salameh, A., Dhein, S., Blanke, K., Rastan, A. J., Hiyasat, B., Dietze, A., Sobiraij, A., Dähnert, I., & Janoušek, J. (2012) · Circulation · doi:10.1161/circulationaha.111.079087 · Cited by 23
Cardiac Implantable Electronic Devices Following Heart Transplantation
DeFilippis, E. M., Rubin, G. A., FARR, M. A., BIVIANO, A. B., Wan, E. Y., Takeda, K., Garan, H., Topkara, V. K., & Yarmohammadi, H. (2020) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2020.06.023 · Cited by 23
Physiology of Left Ventricular Septal Pacing and Left Bundle Branch Pacing
Rijks, J. H. J., LUERMANS, J. G. L. M., Heckman, L. I. B., van Stipdonk, A. M. W., Prinzen, F. W., Lumens, J., & Vernooy, K. (2022) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.12.010 · Cited by 23
Selective site right ventricular pacing
Albouaini, K., Alkarmi, A., Mudawi, T. O., GAMMAGE, M. D., & Wright, D. J. (2009) · Heart · doi:10.1136/hrt.2009.171835 · Cited by 23
Contemporary Pacemakers: What the Primary Care Physician Needs to Know
Kaszala, K., Huizar, J. F., & Ellenbogen, K. A. (2008) · Mayo Clinic Proceedings · doi:10.4065/83.10.1170 · Cited by 23
Self-citationStockburger, M. A., Defaye, P., Bovéda, S., Stancak, B., Lazarus, A., Sipötz, J., Nardi, S., Rolando, M., & Moreno, J. (2015) · EP Europace · doi:10.1093/europace/euv358 · Cited by 23
Russo, V., Rago, A., Papa, A. A., Politano, L., Golino, P., Russo, M. G., Calabrò, R., & Nigro, G. (2013) · Kardiologia Polska · doi:10.5603/kp.2013.0295 · Cited by 23
Gwag, H. B., Chun, K. J., Hwang, J. K., Park, K., On, Y. K., Kim, J. S., & Park, S. (2017) · Yonsei Medical Journal · doi:10.3349/ymj.2017.58.4.703 · Cited by 23
Antegrade Conduction Rescues Right Ventricular Pacing-Induced Cardiomyopathy in Complete Heart Block
Dawkins, J. F., Hu, Y., Valle, J., Sanchez, L., Zheng, Y., Marbán, E., & Cingolani, E. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.086 · Cited by 23
Pacing devices to treat bradycardia: current status and future perspectives
Biffi, M., Capobianco, C., Spadotto, A., Bartoli, L., Sorrentino, S., Minguzzi, A., Piemontese, G. P., Angeletti, A., Toniolo, S., & Statuto, G. (2020) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1866543 · Cited by 23
Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Glotzer, T. V., Silverman, R., Yee, R. K., Lee, K. L., Lamas, G. A., & for the MOST Investigators (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03146.x · Cited by 23
Self-citationRicci, R. P., Quesada, A., Almendral, J. M., Arribas, F., Wolpert, C., Adragão, P., Zoni-Berisso, M., Navarro, X., DeSanto, T., Grammatico, A., et al. (2009) · EP Europace · doi:10.1093/europace/eup072 · Cited by 23
Singh, S. N., Poole, J., Anderson, J., Hellkamp, A. S., Karasik, P., Mark, D. B., Lee, K. L., & Bardy, G. H. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.08.012 · Cited by 23
Self-citationAtrial Threshold Variability: Implications for Automatic Atrial Stimulation Algorithms
Biffi, M., Spitali, G., Silvetti, M. S., Argnani, S., Rubino, I., Fontana, P., BARBATO, G., Mazzini, E., Santo, T. D., Drago, F., et al. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00890.x · Cited by 23
Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement
Ureña, M., & Rodés‐Cabau, J. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.09.010 · Cited by 23
New Insights into Pacing Induced Cardiomyopathy
Kim, S. S., & Park, H. W. (2024) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2504118 · Cited by 22
Pacing-associated cardiomyopathy in adult congenital heart disease
Moore, B. M., MEDI, C., McGuire, M. A., Celermajer, D. S., & Cordina, R. (2020) · Open Heart · doi:10.1136/openhrt-2020-001374 · Cited by 22
Usefulness of delivery catheter on accurate right ventricular septal pacing: Mt FUJI trial
Naruse, Y., Sano, M., Kurebayashi, N., Morikawa, S., Tsurumi, N., Shiozawa, T., Takano, S., Ogano, M., Kimura, K., Miyajima, K., et al. (2023) · EP Europace · doi:10.1093/europace/euad027 · Cited by 22
Mao, Y., Duchenne, J., Yang, Y., Garweg, C., Yang, Y., Sheng, X., Zhang, J., Ye, Y., Wang, M., Paton, M. F., et al. (2023) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jead296 · Cited by 22
Pacing from the Right Ventricular Septum: Is There a Danger to the Coronary Arteries?
Teh, A. W., MEDI, C., Rosso, R., Lee, G., Gurvitch, R., & Mond, H. G. (2009) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02405.x · Cited by 22
Xie, J., Fang, F., Zhang, Q., Chan, J. Y., Yip, G. W., Sanderson, J. E., Lam, Y., YAN, B. P. ‐., & Yu, C. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02210.x · Cited by 22
Atrial fibrillation and heart failure: intersecting populations, morbidities, and mortality
Dickinson, O., Chen, L. Y., & Francis, G. S. (2013) · Heart Failure Reviews · doi:10.1007/s10741-013-9409-4 · Cited by 22
Fauchier, L., Alonso, C., Anselme, F., Blangy, H., Bordachar, P., Bovéda, S., Clémenty, N., Defaye, P., Deharo, J., Friocourt, P., et al. (2016) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2016.04.004 · Cited by 22
Heckman, L. I. B., LUERMANS, J. G. L. M., Jastrzębski, M., Weijs, B., van Stipdonk, A. M. W., Westra, S. W., den Uijl, D. W., Linz, D., Mafi-Rad, M., Prinzen, F. W., et al. (2022) · Netherlands Heart Journal · doi:10.1007/s12471-022-01679-7 · Cited by 22
Sweeney, M. O., Ellenbogen, K. A., Miller, E. H., Sherfesee, L., Sheldon, T., & Whellan, D. J. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00656.x · Cited by 22
Self-citationFröhlig, G., Schwaab, B., & Kindermann, M. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00547.x · Cited by 22
Cardiac Resynchronization Therapy for Heart Failure
Ojo, A. O., Tariq, S., Harikrishnan, P., Iwai, S., & Jacobson, J. T. (2017) · Interventional Cardiology Clinics · doi:10.1016/j.iccl.2017.03.010 · Cited by 21
Park, S. M., Lee, S. Y., Jung, M., Youn, J., Kim, D., Cho, J. Y., Cho, D., Hyun, J., Cho, H., Park, S., et al. (2023) · International Journal of Heart Failure · doi:10.36628/ijhf.2023.0016 · Cited by 21
Current Role of Atrioventricular Junction (AVJ) Ablation
Hoffmayer, K. S., & Scheinman, M. M. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12022 · Cited by 21
Auger, D., Höke, U., Marsan, N. A., Tops, L. F., Leong, D. P., Bertini, M., Schalij, M. J., Bax, J. J., & Delgado, V. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12397 · Cited by 21
Sanagala, T., Johnston, S. L., GROOT, G. D., RHINE, D. K., & Varma, N. (2011) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02061.x · Cited by 21
Focus on right ventricular outflow tract septal pacing
Costa, A. D., Laurent, G., Romeyer-Bouchard, C., Bertaux, G., Gate-Martinet, A., Bisch, L., Levallois, M., & Isaaz, K. (2013) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2012.08.005 · Cited by 21
Zhang, H. X., Qian, J., Hou, F. Q., Liu, Y. N., & Mao, J. H. (2012) · PubMed · Cited by 21
Kim, B. S., Chun, K. J., Hwang, J. K., Park, S., Park, K., Kim, J. S., & On, Y. K. (2016) · Medicine · doi:10.1097/md.0000000000004181 · Cited by 21
Yamasaki, H., Lustgarten, D. L., Cerkvenik, J., Birnie, D. H., Gasparini, M., Lee, K. L.-F., Sekiguchi, Y., Varma, N., Lemke, B., Starling, R. C., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.04.036 · Cited by 21
Self-citationKhurwolah, M. R., Yao, J., & Kong, X. (2018) · Current Cardiology Reviews · doi:10.2174/1573403x15666181129161839 · Cited by 21
Evaluation of Data Telemetry for Future Leadless Cardiac Pacemaker
Bose, P., Khaleghi, A., Mahmood, S., Albatat, M., Bergsland, J., & Balasingham, I. (2019) · IEEE Access · doi:10.1109/access.2019.2950146 · Cited by 21
Redefining physiologic pacing: Lessons learned from recent clinical trials
Gillis, A. M. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.010 · Cited by 21
New Developments in Cardiac Pacemakers
Vardas, P. E., SIMANTIRAKIS, E. N., & KANOUPAKIS, E. M. (2013) · Circulation · doi:10.1161/circulationaha.112.000086 · Cited by 21
Left Bundle Branch Block After Transcatheter Aortic Valve Implantation
Colombo, A., & Latib, A. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.034 · Cited by 21
Garcia, R., Warming, P. E., Narayanan, K., Defaye, P., Guédon-Moreau, L., Blangy, H., Piot, O., Leclercq, C., Marijon, É., the WEARIT-France Investigators, et al. (2023) · EP Europace · doi:10.1093/europace/euad062 · Cited by 20
Acosta, H., Viáfara, L. M., Izquierdo, D., Pothula, V. R., Bear, J., Pothula, S., Antonio-Drabeck, C., & Lee, K. (2012) · EP Europace · doi:10.1093/europace/eus043 · Cited by 20
Self-citationSwerdlow, C. D., Gillberg, J. M., & Olson, W. H. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-2536-8.50008-x · Cited by 20
Chronic Right Ventricular Pacing in the Heart Failure Population
Gould, J., Sieniewicz, B., Porter, B., Sidhu, B. S., & Rinaldi, C. A. (2018) · Current Heart Failure Reports · doi:10.1007/s11897-018-0376-x · Cited by 20
Sun, J., Sha, Y., Sun, Q., Qiu, Y., Shao, B., Ni, Y.-H., Mei, Y., Zhang, C., & Wang, R. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14445 · Cited by 20
Acute Effects of Right Ventricular Apical Pacing on Left Atrial Remodeling and Function
Xie, J., Fang, F., Zhang, Q., Sanderson, J. E., Chan, J. Y., Lam, Y., & Yu, C. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03403.x · Cited by 20
The Role of Speckle Tracking Strain Imaging in Cardiac Pacing
Tops, L. F., Delgado, V., & Bax, J. J. (2009) · Echocardiography · doi:10.1111/j.1540-8175.2008.00865.x · Cited by 20
Zhang, Q., Fang, F., Yip, G. W., Chan, J. Y., Shang, Q., Fung, J. W., Chan, A. K.-Y., Liang, Y.-J., & Yu, C. (2008) · American Heart Journal · doi:10.1016/j.ahj.2008.06.027 · Cited by 20
Albertsen, A. E., & Nielsen, J. C. (2003) · Cardiac Electrophysiology Review · doi:10.1023/b:cepr.0000023156.58418.2a · Cited by 20
Willems, R., Wyse, D. G., Gillis, A. M., & Atrial Pacing Periablation for Paroxysmal Atrial Fibrillation (PA) Study Investigators (2003) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2003.03159.x · Cited by 20
Kolb, C., Deisenhofer, I., Schmieder, S., Barthel, P., Zrenner, B., KARCH, M. R., & Schmitt, C. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00467.x · Cited by 20
Belhassen, B. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.028 · Cited by 20
Metadata
- Authors
- Sweeney, M. O., Hellkamp, A. S., Ellenbogen, K. A., Greenspon, A. J., Freedman, R. A., Lee, K. L., & Lamas, G. A.
- Affiliations
- Brigham and Women's Hospital (US)
- Corresponding author
- Sweeney, Michael O.
- ORCID
- Venue
- Circulation
- Published
- 2003-06-17
- Volume
- 107
- Issue
- 23
- Pages
- 2932-2937
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1992880616
- Semantic Scholar
- f64ee53940d6857ca50be244f1edf56583485f93
- Cited by
- 1,773
- References
- 22
- Citations by year
- 2026: 63 · 2025: 87 · 2024: 79 · 2023: 109 · 2022: 79 · 2021: 94 · 2020: 80 · 2019: 68 · 2018: 82 · 2017: 74 · 2016: 71 · 2015: 70 · 2014: 69 · 2013: 66 · 2012: 75
- FWCI
- 46.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5u01hl053973-05)
- National Heart, Lung, and Blood Institute (U01HL049804, U01 HL 53973, U01-HL-49804)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- ventricular pacing, sick sinus syndrome, heart failure hospitalization, atrial fibrillation, DDD pacing, QRS duration, pacemaker therapy
- MeSH terms
- Aged, Aged, 80 and over, Atrial Fibrillation, Bradycardia, Cardiac Pacing, Artificial, Electrocardiography, Female, Follow-Up Studies, Heart Failure, Hospitalization, Humans, Male, Sick Sinus Syndrome, Proportional Hazards Models, Survival Analysis, Randomized Controlled Trials as Topic, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review