Background— The purpose of this study was to visualize atherosclerotic plaques independently of luminal narrowing using T 1 -weighted contrast-enhanced MRI. Methods and Results— Eight Watanabe heritable hyperlipidemic (WHHL) rabbits, aged 9 to 18 months, and 8 age-matched controls (New Zealand White rabbits) underwent MRI of the aortic arch before and up to 48 hours after injection of 100 μmol/kg Gadofluorine (Schering AG). Additionally, 8 WHHL rabbits were examined with Magnevist (Schering AG). A half-Fourier acquisition single-shot turbo-spin-echo (HASTE) sequence and a T 1 -weighted inversion-recovery turbo fast, low-angle shot sequence were used for data acquisition. Immediately after the MR examination, the animals were killed, the aorta was stained with Sudan red, and ex vivo imaging of the stained aortic specimens was performed. Additionally, gadolinium concentrations in plaque (Sudan-positive) and normal (Sudan-negative) aortic wall segments were measured. Plain MR imaging revealed no plaques in the aortic arch in either animal group. Enhancement occurred in the aortic wall of all WHHL rabbits examined with Gadofluorine but not in the vessel wall of animals examined with Magnevist and the control group. Sudan red staining demonstrated multiple plaques in the aortic arch of all WHHL rabbits. Ex vivo imaging demonstrated that the area of hyperenhancement matched the area of plaques stained with Sudan red. The gadolinium concentration was 7±5 nmol/g for normal aortic wall of the control group and 368±30 nmol/g for aortic wall with plaque in WHHL. Conclusions— Gadofluorine enhances the imaging of atherosclerotic plaques and enables improved plaque detection of even nonstenotic lesions that are not visible on unenhanced MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Cited by
Lipid‐based nanoparticles for contrast‐enhanced MRI and molecular imaging
Mulder, W. J. M., Strijkers, G. J., van Tilborg, G. A. F., Griffioen, A. W., & Nicolay, K. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1011 · Cited by 535
Molecular, cellular and functional imaging of atherothrombosis
Choudhury, R. P., Fuster, V., & Fayad, Z. A. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1548 · Cited by 252
Sirol, M., Itskovich, V. V., Mani, V., Aguinaldo, J. G. S., Fallon, J. T., Misselwitz, B., Weinmann, H.-J., Fuster, V., Toussaint, J.-F., & Fayad, Z. A. (2004) · Circulation · doi:10.1161/01.cir.0000129310.17277.e7 · Cited by 192
Self-citation
Metadata
- Authors
- Barkhausen, J., Ebert, W., Heyer, C., Debatin, J. F., & Weinmann, H.-J.
- Venue
- Circulation
- Published
- 2003-08-05
- Volume
- 108
- Issue
- 5
- Pages
- 605-609
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2160271782
- Cited by
- 164
- References
- 1
- FWCI
- 11.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of Atherosclerotic Plaque With Gadofluorine-Enhanced Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1161/01.cir.0000079099.36306.10
- The paper
- Barkhausen, J., Ebert, W., Heyer, C., Debatin, J. F., & Weinmann, H.-J. (2003). Detection of Atherosclerotic Plaque With Gadofluorine-Enhanced Magnetic Resonance Imaging. Circulation. https://doi.org/10.1161/01.cir.0000079099.36306.10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.