Impact of Valve Prosthesis-Patient Mismatch on Short-Term Mortality After Aortic Valve Replacement
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Background— The prosthesis used for aortic valve replacement (AVR) can be too small in relation to body size, thus causing valve prosthesis-patient mismatch (PPM) and abnormally high transvalvular pressure gradients. This study examined if there is a relation between PPM and short-term mortality after operation. Methods and Results— The indexed valve effective orifice area (EOA) was estimated for each type and size of prosthesis being implanted in 1266 consecutive patients and used to define PPM as not clinically significant if >0.85 cm 2 /m 2 , as moderate if >0.65 cm 2 /m 2 and ≤0.85 cm 2 /m 2 , and as severe if ≤0.65 cm 2 /m 2 ; it was correlated with 30-day mortality and compared with other relevant variables. Moderate or severe PPM was present in 38% of patients. Thirty-day mortality was 4.6% (58/1266 patients) and the strongest independent predictors in multivariate analysis were left ventricular ejection fraction <40% ( P =0.007), infectious endocarditis ( P =0.002), emergent/salvage operation ( P =0.002), cardiopulmonary bypass time >120 minutes ( P =0.001), and PPM ( P =0.003). Relative risk of mortality was increased 2.1-fold (95% confidence interval, 1.2 to 3.7) in patients with moderate PPM and 11.4-fold (4.4 to 29.5) in those with severe PPM. Moreover, risk of mortality for every category of PPM was higher in patients with a left ventricular ejection fraction <40% as compared with ≥40% (nonsignificant PPM, 2.7 versus 1.0; moderate PPM, 7.1 versus 1.8; severe PPM, 77.1 versus 11.3). Conclusion— PPM is a strong and independent predictor of short-term mortality among patients undergoing AVR, and its impact is related both to its degree of severity and the status of left ventricular function. In contrast to other risk factors, moderate-severe PPM can be largely avoided with the use of a prospective strategy at the time of operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The problem of valve prosthesis-patient mismatch.
Rahimtoola, S. H. (1978) · Circulation · doi:10.1161/01.cir.58.1.20 · Cited by 853
Pibarot, P., & Dumesnil, J. G. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00859-7 · Cited by 674
Self-citationAlexander, K. P., Anstrom, K. J., Muhlbaier, L. H., Grosswald, R. D., Smith, P. K., Jones, R. H., & Peterson, E. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00606-3 · Cited by 570
Guidelines for Reporting Morbidity and Mortality After Cardiac Valvular Operations
Edmunds, L. H., Clark, R. E., Cohn, L. H., Grunkemeier, G. L., Miller, D. C., & Weisel, R. D. (1996) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(96)00531-0 · Cited by 534
Prediction of operative mortality after valve replacement surgery
Edwards, F. H., Peterson, E. D., Coombs, L. P., DeLong, E. R., Jamieson, W. R. E., Shroyer, A. L. W., & Grover, F. L. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01202-x · Cited by 420
Connolly, H. M., Oh, J. K., Schaff, H. V., Roger, V. L., Osborn, S. L., Hodge, D. O., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.101.16.1940 · Cited by 356
Prosthesis-Patient Mismatch Affects Survival After Aortic Valve Replacement
Rao, V., Jamieson, W. R. E., Ivanov, J., Armstrong, S., & David, T. E. (2000) · Circulation · doi:10.1161/01.cir.102.suppl_3.iii-5 · Cited by 312
Risk stratification for cardiac valve replacement. National Cardiac Surgery Database
Jamieson, W. R. E., Edwards, F. H., Schwartz, M., Bero, J. W., Clark, R. E., & Grover, F. L. (1999) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(99)00175-7 · Cited by 252
Dumesnil, J. G., Honos, G. N., Lemieux, M., & Beauchemin, J. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90355-s · Cited by 246
Self-citationPîbarot, P., Dumesnil, J. G., Lemieux, M. D., Cartier, P. C., Métras, J., & Durand, L. (1998) · PubMed · Cited by 201
Self-citationAortic valve replacement: Is valve size important?
Medalion, B., Blackstone, E. H., Lytle, B. W., White, J., Arnold, J. H., & Cosgrove, D. M. (2000) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(00)70091-2 · Cited by 165
Patient-prosthesis mismatch can be predicted at the time of operation
Pîbarot, P., Dumesnil, J. G., Cartier, P. C., Métras, J., & Lemieux, M. D. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)02509-7 · Cited by 158
Self-citationRoutine enlargement of the small aortic root: a preventive strategy to minimize mismatch
Castro, L. J., Arcidi, J. M., Fisher, A. L., & Gaudiani, V. A. (2002) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)03680-9 · Cited by 157
Mehta, R. H., Bruckman, D., Das, S., Tsai, T., Russman, P. L., Karavite, D., Monaghan, H., Sonnad, S. S., Shea, M. J., Eagle, K. A., et al. (2001) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.116558 · Cited by 113
Pîbarot, P., Honos, G. N., Durand, L., & Dumesnil, J. G. (1996) · PubMed · Cited by 90
Self-citationDavid, T. E. (1999) · Current Problems in Surgery · doi:10.1016/s0011-3840(99)80802-8 · Cited by 68
Cited by
The Role of Stress Echocardiography in Valvular Heart Disease: A Current Appraisal
Gentry III, J. L., Phelan, D., Desai, M. Y., & Griffin, B. P. (2017) · Cardiology · doi:10.1159/000460274 · Cited by 2,725
Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound
Zoghbi, W. A., Chambers, J. B., Dumesnil, J. G., Foster, E., Gottdiener, J. S., Grayburn, P. A., Khandheria, B. K., Levine, R. A., Marx, G. R., Miller, F. A., et al. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.07.013 · Cited by 1,259
Self-citationHachicha, Z., Dumesnil, J. G., Bogaty, P., & Pibarot, P. (2007) · Circulation · doi:10.1161/circulationaha.106.668681 · Cited by 959
Self-citationProsthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Pibarot, P., & Dumesnil, J. G. (2009) · Circulation · doi:10.1161/circulationaha.108.778886 · Cited by 786
Self-citation2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Metadata
- Authors
- Blais, C., Dumesnil, J. G., Baillot, R., Simard, S., Doyle, D., & Pibarot, P.
- Venue
- Circulation
- Published
- 2003-08-26
- Volume
- 108
- Issue
- 8
- Pages
- 983-988
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2163073305
- Cited by
- 564
- References
- 16
- FWCI
- 15.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.