The DOI matches its Crossref record.
Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations
Abstract
Background— The epicardial location of an arrhythmia could be responsible for unsuccessful endocardial catheter ablation. Methods and Results— In 48 patients referred after prior unsuccessful endocardial ablation, we considered percutaneous, subxiphoid instrumentation of the pericardial space for mapping and ablation. Thirty patients had ventricular tachycardia (VT), 6 patients had a right- and 4 had a left-sided accessory pathway (AP), 4 patients had inappropriate sinus tachycardia, and 4 patients had atrial arrhythmias. Of the 30 VTs, 24 (6 with ischemic cardiomyopathy, 3 with idiopathic cardiomyopathy, and 15 with normal hearts) appeared to originate from the epicardium. Seventeen (71%) of these 24 VTs were successfully ablated with epicardial lesions. The other 7 VTs had early epicardial sites that were inaccessible, predominantly because of interference from the left atrial appendage. Six of these were successfully ablated from the left coronary cusp. In 5 of the 10 patients with an AP, the earliest activation was recorded epicardially. Three of these were right atrial appendage–to–right ventricle APs, and epicardial ablation was successful. No significant complications were observed. Conclusions— Failure of endocardial ablation could reflect the presence of an epicardial arrhythmia substrate. Epicardial instrumentation and ablation appeared feasible and safe and provided an alternative strategy for the treatment of patients with a variety of arrhythmias. This was particularly true for VT, including patients without structural heart disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Daniels, D. V., Lu, Y.-Y., Morton, J. B., Santucci, P. A., Akar, J. G., Green, A., & Wilber, D. J. (2006) · Circulation · doi:10.1161/circulationaha.105.611640 · Cited by 380
Cano, O., Hutchinson, M., Lin, D., Garcia, F., Zado, E., Bala, R., Riley, M., Cooper, J., Dixit, S., Gerstenfeld, E., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.05.032 · Cited by 350
Vatasescu, R., Shalganov, T., Kardos, A., Jalabadze, K., Paprika, D., Gyorgy, M., & Szili-Torok, T. (2006) · EP Europace · doi:10.1093/europace/eul089 · Cited by 20
Metadata
- Authors
- Schweikert, R. A., Saliba, W. I., Tomassoni, G., Marrouche, N. F., Cole, C. R., Dresing, T. J., Tchou, P. J., Bash, D., Beheiry, S., Lam, C., Kanagaratnam, L., & Natale, A.
- Venue
- Circulation
- Published
- 2003-09-16
- Volume
- 108
- Issue
- 11
- Pages
- 1329-1335
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2156963238
- Cited by
- 212
- References
- 0
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations. https://app.cochat.ai/papers/10.1161/01.cir.0000087407.53326.31
- The paper
- Schweikert, R. A., Saliba, W. I., Tomassoni, G., Marrouche, N. F., Cole, C. R., Dresing, T. J., Tchou, P. J., Bash, D., Beheiry, S., Lam, C., Kanagaratnam, L., & Natale, A. (2003). Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations. Circulation. https://doi.org/10.1161/01.cir.0000087407.53326.31
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.