Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record.

Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations

Schweikert, Robert A., Saliba, Walid I., Tomassoni, Gery, Marrouche, Nassir F., Cole, Christopher R., Dresing, Thomas J., Tchou, Patrick J., Bash, Dianna, Beheiry, Salwa, Lam, Cathy, Kanagaratnam, Logan, Natale, Andrea · 2003 · Circulation

Abstract

Background— The epicardial location of an arrhythmia could be responsible for unsuccessful endocardial catheter ablation. Methods and Results— In 48 patients referred after prior unsuccessful endocardial ablation, we considered percutaneous, subxiphoid instrumentation of the pericardial space for mapping and ablation. Thirty patients had ventricular tachycardia (VT), 6 patients had a right- and 4 had a left-sided accessory pathway (AP), 4 patients had inappropriate sinus tachycardia, and 4 patients had atrial arrhythmias. Of the 30 VTs, 24 (6 with ischemic cardiomyopathy, 3 with idiopathic cardiomyopathy, and 15 with normal hearts) appeared to originate from the epicardium. Seventeen (71%) of these 24 VTs were successfully ablated with epicardial lesions. The other 7 VTs had early epicardial sites that were inaccessible, predominantly because of interference from the left atrial appendage. Six of these were successfully ablated from the left coronary cusp. In 5 of the 10 patients with an AP, the earliest activation was recorded epicardially. Three of these were right atrial appendage–to–right ventricle APs, and epicardial ablation was successful. No significant complications were observed. Conclusions— Failure of endocardial ablation could reflect the presence of an epicardial arrhythmia substrate. Epicardial instrumentation and ablation appeared feasible and safe and provided an alternative strategy for the treatment of patients with a variety of arrhythmias. This was particularly true for VT, including patients without structural heart disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000087407.53326.31

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Schweikert, R. A., Saliba, W. I., Tomassoni, G., Marrouche, N. F., Cole, C. R., Dresing, T. J., Tchou, P. J., Bash, D., Beheiry, S., Lam, C., Kanagaratnam, L., & Natale, A.
Venue
Circulation
Published
2003-09-16
Volume
108
Issue
11
Pages
1329-1335
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2156963238
Cited by
212
References
0
FWCI
9.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations. https://app.cochat.ai/papers/10.1161/01.cir.0000087407.53326.31
The paper
Schweikert, R. A., Saliba, W. I., Tomassoni, G., Marrouche, N. F., Cole, C. R., Dresing, T. J., Tchou, P. J., Bash, D., Beheiry, S., Lam, C., Kanagaratnam, L., & Natale, A. (2003). Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations. Circulation. https://doi.org/10.1161/01.cir.0000087407.53326.31

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.