Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record.

Predictors of Improved Renal Function After Percutaneous Stent-Supported Angioplasty of Severe Atherosclerotic Ostial Renal Artery Stenosis

Zeller, Thomas, Frank, Ulrich, Müller, Christian, Bürgelin, Karlheinz, Sinn, Lutz, Bestehorn, Hans-Peter, Cook-Bruns, Nancy, Neumann, Franz-Josef · 2003 · Circulation

Abstract

Background— Percutaneous stent-supported angioplasty is a treatment option for atherosclerotic ostial renal artery stenosis. Improvement of renal function by such intervention, however, is controversial and thought to be limited to specific subsets, such as nondiabetic patients and bilateral stenoses. In this prospective study, we investigated predictors for improvement of renal function and blood pressure after renal artery stent placement. Methods and Results— The study included 215 consecutive patients with ostial renal artery stenosis of ≥70% diameter stenosis undergoing stent-supported angioplasty. The primary end point was decrease in serum creatinine concentration at 1 year; the secondary end point, decrease in average mean arterial blood pressure assessed by 24-hour monitoring. One-year follow-up was complete in 191 surviving patients. In 52% (99/191) of the patients, serum creatinine concentration decreased during 1-year follow-up. Median serum creatinine concentration dropped significantly from 1.21 mg/dL (quartiles: 0.92, 1.60 mg/dL) at baseline to 1.10 mg/dL (quartiles: 0.88, 1.50 mg/dL) at 1 year ( P =0.047). On average, mean arterial blood pressure decreased significantly, from 102±12 mm Hg (mean±SD) at baseline to 92±10 mm Hg at 1 year ( P <0.001). Significant independent predictors of improved renal function were baseline serum creatinine (odds ratio [95% CI], 2.58 [1.35 to 4.94], P =0.004) and left ventricular function (OR 1.51 [1.04 to 2.21], P =0.032). Female sex, high baseline mean blood pressure, and normal renal parenchymal thickness were independent predictors for decreased mean blood pressure. Conclusions— Stent-supported angioplasty for severe ostial renal artery stenosis improves renal function and blood pressure in a broader spectrum of patients than previously thought.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000095786.44712.2a

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Zeller, T., Frank, U., Müller, C., Bürgelin, K., Sinn, L., Bestehorn, H.-P., Cook-Bruns, N., & Neumann, F.-J.
Venue
Circulation
Published
2003-11-04
Volume
108
Issue
18
Pages
2244-2249
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1976096921
Cited by
244
References
0
FWCI
11.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictors of Improved Renal Function After Percutaneous Stent-Supported Angioplasty of Severe Atherosclerotic Ostial Renal Artery Stenosis. https://app.cochat.ai/papers/10.1161/01.cir.0000095786.44712.2a
The paper
Zeller, T., Frank, U., Müller, C., Bürgelin, K., Sinn, L., Bestehorn, H.-P., Cook-Bruns, N., & Neumann, F.-J. (2003). Predictors of Improved Renal Function After Percutaneous Stent-Supported Angioplasty of Severe Atherosclerotic Ostial Renal Artery Stenosis. Circulation. https://doi.org/10.1161/01.cir.0000095786.44712.2a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.