Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

In Vivo Molecular Imaging of Acute and Subacute Thrombosis Using a Fibrin-Binding Magnetic Resonance Imaging Contrast Agent

Open access
Botnar, René M., Perez, Alexandra S., Witte, Sonia, Wiethoff, Andrea J., Laredo, James, Hamilton, James, Quist, William, Parsons, Edward C., Vaidya, Anand, Kolodziej, Andrew, Barrett, John A., Graham, Philip B., Weisskoff, Robert M., Manning, Warren J., Johnstone, Michael T.·2004·Circulation

Abstract

Background— Plaque rupture with subsequent thrombosis is recognized as the underlying pathophysiology of most acute coronary syndromes and stroke. Thus, direct thrombus visualization may be beneficial for both diagnosis and guidance of therapy. We sought to test the feasibility of direct imaging of acute and subacute thrombosis using MRI together with a novel fibrin-binding gadolinium-labeled peptide, EP-1873, in an experimental animal model of plaque rupture and thrombosis. Methods and Results— Fifteen male New Zealand White rabbits (weight, ≈3.5 kg) were made atherosclerotic by feeding a high-cholesterol diet after endothelial aortic injury. Plaque rupture was then induced with the use of Russell’s viper venom (RVV) and histamine. Subsequently, MRI of the subrenal aorta was performed before RVV, after RVV, and after EP-1873. Histology was performed on regions suggested by MRI to contain thrombus. Nine rabbits (60%) developed plaque rupture and thrombus, including 25 thrombi visually apparent on MRI as “hot spots” after injection of EP-1873. Histological correlation confirmed all 25 thrombi (100%), with no thrombi seen in the other regions of the aorta. In the remaining 6 rabbits (control) without plaque rupture, no thrombus was observed on the MR images or on histology. Conclusions— We demonstrate the feasibility of in vivo “molecular” MRI for the detection of acute and subacute thrombosis using a novel fibrin-binding MRI contrast agent in an animal model of atherosclerosis and acute/subacute thrombosis. Potential clinical applications include thrombus detection in acute coronary syndromes and stroke.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000127034.50006.c0

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 271

Metadata

Authors
Botnar, R. M., Perez, A. S., Witte, S., Wiethoff, A. J., Laredo, J., Hamilton, J., Quist, W., Parsons, E. C., Vaidya, A., Kolodziej, A., Barrett, J. A., Graham, P. B., Weisskoff, R. M., Manning, W. J., & Johnstone, M. T.
Venue
Circulation
Published
2004-04-27
Volume
109
Issue
16
Pages
2023-2029
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2132746436
Cited by
271
References
1
FWCI
20.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Molecular Imaging of Acute and Subacute Thrombosis Using a Fibrin-Binding Magnetic Resonance Imaging Contrast Agent. https://app.cochat.ai/papers/10.1161/01.cir.0000127034.50006.c0
The paper
Botnar, R. M., Perez, A. S., Witte, S., Wiethoff, A. J., Laredo, J., Hamilton, J., Quist, W., Parsons, E. C., Vaidya, A., Kolodziej, A., Barrett, J. A., Graham, P. B., Weisskoff, R. M., Manning, W. J., & Johnstone, M. T. (2004). In Vivo Molecular Imaging of Acute and Subacute Thrombosis Using a Fibrin-Binding Magnetic Resonance Imaging Contrast Agent. Circulation. https://doi.org/10.1161/01.cir.0000127034.50006.c0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.