Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 169

The DOI matches its Crossref record.

Detection of Acutely Impaired Microvascular Reperfusion After Infarct Angioplasty With Magnetic Resonance Imaging

Open access
Taylor, Andrew J., Al-Saadi, Nidal, Abdel-Aty, Hassan, Schulz-Menger, Jeanette, Messroghli, Daniel R., Friedrich, Matthias G. · 2004 · Circulation

Abstract

Background— Despite the reopening of the infarct-related artery (IRA) with infarct angioplasty, complete microvascular reperfusion does not always ensue. Methods and Results— We performed cardiovascular MRI (CMR) in 20 acute myocardial infarction (AMI) patients within 24 hours of successful infarct angioplasty and 10 control patients without obstructive coronary artery disease on a clinical 1.5-T CMR scanner. Three-month follow-up CMR in AMI patients evaluated the impact of abnormal reperfusion on recovery of function. Infarction was localized by delayed contrast hyperenhancement and impaired systolic thickening. Microvascular perfusion was assessed at rest by first-pass perfusion CMR after a bolus of gadolinium-DTPA by use of the time to 50% maximum myocardial enhancement. Whereas contrast wash-in was homogeneous in control patients, AMI patients exhibited delays in the hypokinetic region subtended by the IRA compared with remote segments in 19 of 20 patients, with a mean contrast delay of 0.9±0.1 seconds (95% CI, 0.6 to 1.2 seconds). At follow-up, the mean recovery of systolic thickening was lower in segments with a contrast delay of 2 seconds or more (10±7% versus 39±4%, P <0.001). A contrast delay ≥2 seconds and infarction >75% transmurally were independent predictors of impaired left ventricular systolic thickening at 3 months ( P =0.002 for severe contrast delay, P =0.048 for >75% for transmural infarction). Conclusions— CMR detects impaired microvascular reperfusion in AMI patients despite successful infarct angioplasty, which when severe is associated with a lack of recovery of wall motion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000127812.62277.50

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Taylor, A. J., Al-Saadi, N., Abdel-Aty, H., Schulz-Menger, J., Messroghli, D. R., & Friedrich, M. G.
Venue
Circulation
Published
2004-05-04
Volume
109
Issue
17
Pages
2080-2085
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2011490864
Cited by
169
References
0
FWCI
11.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of Acutely Impaired Microvascular Reperfusion After Infarct Angioplasty With Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1161/01.cir.0000127812.62277.50
The paper
Taylor, A. J., Al-Saadi, N., Abdel-Aty, H., Schulz-Menger, J., Messroghli, D. R., & Friedrich, M. G. (2004). Detection of Acutely Impaired Microvascular Reperfusion After Infarct Angioplasty With Magnetic Resonance Imaging. Circulation. https://doi.org/10.1161/01.cir.0000127812.62277.50

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.