Acute Improvement in Global and Regional Left Ventricular Systolic Function After Percutaneous Heart Valve Implantation in Patients With Symptomatic Aortic Stenosis
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background— The newly developed percutaneous heart valve (PHV) implantation technique decreases transaortic pressure gradient in patients with aortic stenosis. PHV replacement effects on left ventricular (LV) global and regional systolic function are currently unknown. Methods and Results— Eight patients with severe aortic stenosis had 2D echocardiography at baseline and 24 hours after PHV implantation to evaluate changes in LV volume and LV ejection fraction. Regional function, ie, both peak systolic anterior and posterior wall tissue velocity, as well as strain and strain rate imaging, were measured by tissue Doppler imaging from a short-axis view. At 24 hours, a significant reduction in transaortic mean pressure gradient (from 46±15 to 8±3 mm Hg; P <0.0001) was accompanied by an increase in aortic valve area (from 0.59±0.11 to 1.69±0.11 cm 2 ; P <0.0001). LV end-diastolic volume remained unchanged (102±36 to 101±12 mL; P =NS), whereas LV ejection fraction increased (48±18% to 57±12%; P <0.01). Improvement in posterior wall displacement (posterior wall tissue velocity increased from 2.2±0.5 to 4.4±1.0 cm/s −1 ; P =0.0003) and deformation (strain rate imaging increased from 1.0±0.3 to 1.9±0.7 s −1 , P =0.009, and strain increased from 11±5% to 17±9%; P =0.02) were observed. Conclusions— Immediately after PHV replacement, improvement of LV global and regional systolic function was evidenced by tissue Doppler imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kaden, J. J., Dempfle, C.-E., Grobholz, R., Tran, H.-T., Kılıç, R., Sarıkoç, A., Brueckmann, M., Vahl, C., Hagl, S., Haase, K. K., et al. (2003) · Atherosclerosis · doi:10.1016/s0021-9150(03)00284-3 · Cited by 272
Cited by
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Self-citationGrube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.639450 · Cited by 655
Transapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience
Walther, T., Simon, P., Dewey, T., Wimmer-Greinecker, G., Falk, V., Kasimir, M. T., Doss, M., Borger, M. A., Schuler, G., Glogar, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.677237 · Cited by 618
Measurement of Strain and Strain Rate by Echocardiography
Marwick, T. H. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.063 · Cited by 597
Eltchaninoff, H., Prat, A., Gilard, M., Leguerrier, A., Blanchard, D., Fournial, G., Iung, B., Donzeau-Gouge, P., Tribouilloy, C., Debrux, J.-L., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq261 · Cited by 554
Self-citationTranscatheter aortic valve implantation: current and future approaches
Rodés-Cabau, J. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.164 · Cited by 306
“The improvement in valve hemodynamics associated with TAVI translates into a significant improvement in LVEF, especially in patients with low LVEF”
BackgroundClavel, M. A., Webb, J. G., Rodés-Cabau, J., Masson, J. B., Dumont, E., De Larochellière, R., Doyle, D., Bergeron, S., Baumgartner, H., Burwash, I. G., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.929893 · Cited by 304
Minimally invasive transapical beating heart aortic valve implantation — proof of concept
Walther, T., Falk, V., Borger, M. A., Dewey, T., Wimmer-Greinecker, G., Schuler, G., Mack, M., & Mohr, F. W. (2007) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.10.034 · Cited by 230
“All these factors may result in the transapical procedure being the preferred approach when compared to the retrograde transfemoral arterial and transseptal femoral venous approaches that have been applied [7—9].”
MethodResultLafitte, S., Perlant, M., Reant, P., Serri, K., Douard, H., DeMaria, A., & Roudaut, R. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen299 · Cited by 201
Donal, E., Bergerot, C., Thibault, H., Ernande, L., Loufoua, J., Augeul, L., Ovize, M., & Derumeaux, G. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep095 · Cited by 186
Assessment of left ventricular function in aortic stenosis
Ozkan, A., Kapadia, S., Tuzcu, M., & Marwick, T. H. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.80 · Cited by 57
“Subtle myocardial dysfunction in patients with AS, and the improvement in myocardial deformation parameters after percutaneou”
Background
Metadata
- Authors
- Bauer, F., Eltchaninoff, H., Tron, C., Lesault, P.-F., Agatiello, C., Nercolini, D., Derumeaux, G., & Cribier, A.
- Venue
- Circulation
- Published
- 2004-09-14
- Volume
- 110
- Issue
- 11
- Pages
- 1473-1476
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2078663478
- Cited by
- 148
- References
- 1
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.