CoChat

Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow

Open access
Muthurangu, Vivek, Taylor, Andrew, Andriantsimiavona, Rado, Hegde, Sanjeet, Miquel, Marc E., Tulloh, Robert, Baker, Edward, Hill, Derek L.G., Razavi, Reza S. · 2004 · Circulation
Cited by 165

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background— Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements. Methods and Results— In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide +30% (condition 2) and at 20 ppm nitric oxide +100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients. In 15 of 19 patients, PVR calculated by Fick flow was compared with the MR method. At condition 1, Bland-Altman analysis revealed a bias of 2.3% (MR > Fick) and limits of agreement of 50.2% to −45.5%. At condition 2, there was poorer agreement (bias was 28%, and the limits of agreement were 151.3% to 95.2%). At condition 3, there was very poor agreement (bias was 54.2%, and the limits of agreement were 174.4% to −66.0%). Conclusions— We have demonstrated the feasibility of using simultaneous invasive pressure measurements and MR flow data to measure PVR in humans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000138741.72946.84

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 165

Metadata

Authors
Muthurangu, V., Taylor, A., Andriantsimiavona, R., Hegde, S., Miquel, M. E., Tulloh, R., Baker, E., Hill, D. L. G., & Razavi, R. S.
Venue
Circulation
Published
2004-08-17
Volume
110
Issue
7
Pages
826-834
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2103659541
Cited by
165
References
9
FWCI
5.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow. https://app.cochat.ai/papers/10.1161/01.cir.0000138741.72946.84
The paper
Muthurangu, V., Taylor, A., Andriantsimiavona, R., Hegde, S., Miquel, M. E., Tulloh, R., Baker, E., Hill, D. L. G., & Razavi, R. S. (2004). Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow. Circulation. https://doi.org/10.1161/01.cir.0000138741.72946.84

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.