Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background— Pulmonary vascular resistance (PVR) quantification is important in the treatment of children with pulmonary hypertension. The Fick principle, used to quantify pulmonary artery flow, may be a flawed technique. We describe a novel method of PVR quantification by the use of magnetic resonance (MR) flow data and invasive pressure measurements. Methods and Results— In 24 patients with either suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment, PVR was calculated by the use of simultaneously acquired MR flow and invasive pressure measurements (condition 1). In 19 of the 24 patients, PVR was also calculated at 20 ppm nitric oxide +30% (condition 2) and at 20 ppm nitric oxide +100% oxygen (condition 3), with the use of the MR method. This method proved safe and feasible in all patients. In 15 of 19 patients, PVR calculated by Fick flow was compared with the MR method. At condition 1, Bland-Altman analysis revealed a bias of 2.3% (MR > Fick) and limits of agreement of 50.2% to −45.5%. At condition 2, there was poorer agreement (bias was 28%, and the limits of agreement were 151.3% to 95.2%). At condition 3, there was very poor agreement (bias was 54.2%, and the limits of agreement were 174.4% to −66.0%). Conclusions— We have demonstrated the feasibility of using simultaneous invasive pressure measurements and MR flow data to measure PVR in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Haemodynamic evaluation of pulmonary hypertension
Chemla, D., Castelain, V., Hervé, P., Lecarpentier, Y., & Brimioulle, S. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00068002 · Cited by 337
In Vivo Validation of MR Velocity Imaging
Firmin, D. N., Nayler, G. L., Klipstein, R. H., Underwood, S. R., Rees, R. S. O., & Longmore, D. B. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198709000-00001 · Cited by 332
Beerbaum, P., Körperich, H., Barth, P., Esdorn, H., Gieseke, J., & Meyer, H. (2001) · Circulation · doi:10.1161/01.cir.103.20.2476 · Cited by 309
Quantitation of cardiac output with velocity-encoded, phase-difference magnetic resonance imaging
Hundley, W. G., Li, H. F., Hillis, L. D., Meshack, B. M., Lange, R. A., Willard, J. E., Landau, C., & Peshock, R. M. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80772-3 · Cited by 163
Combined effects of nitric oxide and oxygen during acute pulmonary vasodilator testing
Atz, A. M., Adatia, I., Lock, J. E., & WESSEL, D. L. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00668-8 · Cited by 127
Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients
Tissot, S., Delafosse, B. X., Bertrand, O., Bouffard, Y., Viale, J. P., & Annat, G. J. (1995) · Intensive Care Medicine · doi:10.1007/bf01726538 · Cited by 120
Lack of Agreement Between Thermodilution and Fick Cardiac Output in Critically Ill Patients
Dhingra, V. K., Fenwick, J. C., Walley, K. R., Chittock, D. R., & Ronco, J. J. (2002) · CHEST Journal · doi:10.1378/chest.122.3.990 · Cited by 101
Lack of long-term ventricular arrhythmia reduction by enalapril in heart failure
Pratt, C. M., Gardner, M. J., Pepine, C. J., Kohn, R. M., Young, J. B., Greenberg, B., Capone, R. J., Kostis, J. B., Henzlova, M. J., Gosselin, G., et al. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80771-1 · Cited by 64
Cited by
Kilner, P. J., Geva, T., Kaemmerer, H., Trindade, P. T., Schwitter, J., & Webb, G. D. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp586 · Cited by 429
SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
Leiner, T., Bogaert, J., Friedrich, M. G., Mohiaddin, R., Muthurangu, V., Myerson, S., Powell, A. J., Raman, S. V., & Pennell, D. J. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00682-4 · Cited by 328
Self-citationPenny, D. J., & Vick, G. W. (2011) · The Lancet · doi:10.1016/s0140-6736(10)61339-6 · Cited by 299
Pulmonary Arterial Hypertension: Noninvasive Detection with Phase-Contrast MR Imaging
Sanz, J., Kuschnir, P., Rius, T., Salguero, R., Sulica, R., Einstein, A. J., Dellegrottaglie, S., Fuster, V., Rajagopalan, S., & Poon, M. (2007) · Radiology · doi:10.1148/radiol.2431060477 · Cited by 227
Pulmonary hypertension related to congenital heart disease: a call for action
Dimopoulos, K., Wort, S. J., & Gatzoulis, M. A. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht437 · Cited by 189
Metadata
- Authors
- Muthurangu, V., Taylor, A., Andriantsimiavona, R., Hegde, S., Miquel, M. E., Tulloh, R., Baker, E., Hill, D. L. G., & Razavi, R. S.
- Venue
- Circulation
- Published
- 2004-08-17
- Volume
- 110
- Issue
- 7
- Pages
- 826-834
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2103659541
- Cited by
- 165
- References
- 9
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow. https://app.cochat.ai/papers/10.1161/01.cir.0000138741.72946.84
- The paper
- Muthurangu, V., Taylor, A., Andriantsimiavona, R., Hegde, S., Miquel, M. E., Tulloh, R., Baker, E., Hill, D. L. G., & Razavi, R. S. (2004). Novel Method of Quantifying Pulmonary Vascular Resistance by Use of Simultaneous Invasive Pressure Monitoring and Phase-Contrast Magnetic Resonance Flow. Circulation. https://doi.org/10.1161/01.cir.0000138741.72946.84
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.