The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Comparison of Dobutamine Stress Magnetic Resonance, Adenosine Stress Magnetic Resonance, and Adenosine Stress Magnetic Resonance Perfusion
Open accessAbstract
Background— Dobutamine stress MR (DSMR) is highly accurate for the detection of inducible wall motion abnormalities (IWMAs). Adenosine has a more favorable safety profile and is well established for the assessment of myocardial perfusion. We evaluated the diagnostic value of IWMAs during dobutamine and adenosine stress MR and adenosine MR perfusion compared with invasive coronary angiography. Methods and Results— Seventy-nine consecutive patients (suspected or known coronary disease, no history of prior myocardial infarction) scheduled for cardiac catheterization underwent cardiac MR (1.5 T). After 4 minutes of adenosine infusion (140 μg · kg −1 · min −1 for 6 minutes), wall motion was assessed (steady-state free precession), and subsequently perfusion scans (3-slice turbo field echo-echo planar imaging; 0.05 mmol/kg Gd-BOPTA) were performed. After a 15-minute break, rest perfusion was imaged, followed by standard DSMR/atropine stress MR. Wall motion was classified as pathological if ≥1 segment showed IWMAs. The transmural extent of inducible perfusion deficits (<25%, 25% to 50%, 51% to 75%, and >75%) was used to grade segmental perfusion. Quantitative coronary angiography was performed with significant stenosis defined as >50% diameter stenosis. Fifty-three patients (67%) had coronary artery stenoses >50%; sensitivity and specificity for detection by dobutamine and adenosine stress and adenosine perfusion were 89% and 80%, 40% and 96%, and 91% and 62%, respectively. Adenosine IWMAs were seen only in segments with >75% transmural perfusion deficit. Conclusions— DSMR is superior to adenosine stress for the induction of IWMAs in patients with significant coronary artery disease. Visual assessment of adenosine stress perfusion is sensitive with a low specificity, whereas adenosine stress MR wall motion is highly specific because it identifies only patients with high-grade perfusion deficits. Thus, DSMR is the method of choice for current state-of-the-art treatment regimens to detect ischemia in patients with suspected or known coronary artery disease but no history of prior myocardial infarction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., Gardin, J. M., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02848-6 · Cited by 1,689
Nagel, E., Lehmkuhl, H. B., Bocksch, W., Klein, C., Vogel, U., Frantz, E., Ellmer, A., Dreysse, S., & Fleck, E. (1999) · Circulation · doi:10.1161/01.cir.99.6.763 · Cited by 792
Self-citationMagnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Nagel, E., Klein, C., Paetsch, I., Hettwer, S., Schnackenburg, B., Wegscheider, K., & Fleck, E. (2003) · Circulation · doi:10.1161/01.cir.0000080915.35024.a9 · Cited by 627
Self-citationAl-Saadi, N., Nagel, E., Gross, M., Bornstedt, A., Schnackenburg, B., Klein, C., Klimek, W., Oswald, H., & Fleck, E. (2000) · Circulation · doi:10.1161/01.cir.101.12.1379 · Cited by 578
Self-citationCommittee Members, Gibbons, R. J., Abrams, J., Chatterjee, K., Daley, J., Deedwania, P. C., Douglas, J. S., Ferguson, T. B., Fihn, S. D., Fraker, T. D., et al. (2003) · Circulation · doi:10.1161/01.cir.0000047041.66447.29 · Cited by 567
Beller, G. A., & Zaret, B. L. (2000) · Circulation · doi:10.1161/01.cir.101.12.1465 · Cited by 404
Marwick, T. H., Willemart, B., D'hondt, A.-M., Baudhuin, T., Wijns, W. C., Detry, J. M., & Melin, J. (1993) · Circulation · doi:10.1161/01.cir.87.2.345 · Cited by 357
Armstrong, W. F., Pellikka, P. A., Ryan, T., Crouse, L., & Zoghbi, W. A. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70132-4 · Cited by 357
Cited by
Fletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
ACC/AHA 2007 Guidelines on Perioperative Cardiovascular Evaluation and Care for Noncardiac Surgery
Fleisher, L. A., Beckman, J. A., Brown, K. A., Calkins, H., Chaikof, E. L., Fleischmann, K. E., Freeman, W. K., Froehlich, J. B., Kasper, E. K., Kersten, J. R., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.003 · Cited by 1,428
Greenwood, J. P., Maredia, N., Younger, J. F., Brown, J. M., Nixon, J., Everett, C. C., Bijsterveld, P., Ridgway, J. P., Radjenovic, A., Dickinson, C. J., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(11)61335-4 · Cited by 1,114
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Metadata
- Authors
- Paetsch, I., Jahnke, C., Wahl, A., Gebker, R., Neuss, M., Fleck, E., & Nagel, E.
- Venue
- Circulation
- Published
- 2004-08-17
- Volume
- 110
- Issue
- 7
- Pages
- 835-842
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2136317102
- Cited by
- 333
- References
- 13
- FWCI
- 21.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Dobutamine Stress Magnetic Resonance, Adenosine Stress Magnetic Resonance, and Adenosine Stress Magnetic Resonance Perfusion. https://app.cochat.ai/papers/10.1161/01.cir.0000138927.00357.fb
- The paper
- Paetsch, I., Jahnke, C., Wahl, A., Gebker, R., Neuss, M., Fleck, E., & Nagel, E. (2004). Comparison of Dobutamine Stress Magnetic Resonance, Adenosine Stress Magnetic Resonance, and Adenosine Stress Magnetic Resonance Perfusion. Circulation. https://doi.org/10.1161/01.cir.0000138927.00357.fb
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.