Chest Compression Rates During Cardiopulmonary Resuscitation Are Suboptimal: A Prospective Study During In-Hospital Cardiac Arrest
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background— Recent data highlight a vital link between well-performed cardiopulmonary resuscitation (CPR) and survival after cardiac arrest; however, the quality of CPR as actually performed by trained healthcare providers is largely unknown. We sought to measure in-hospital chest compression rates and to determine compliance with published international guidelines. Methods and Results— We developed and validated a handheld recording device to measure chest compression rate as a surrogate for CPR quality. A prospective observational study of adult cardiac arrests was performed at 3 hospitals from April 2002 to October 2003. Resuscitations were witnessed by trained observers using a customized personal digital assistant programmed to store the exact time of each chest compression, allowing offline calculation of compression rates at serial time points. In 97 arrests, data from 813 minutes during which chest compressions were delivered were analyzed in 30-second time segments. In 36.9% of the total number of segments, compression rates were <80 compressions per minute (cpm), and 21.7% had rates <70 cpm. Higher chest compression rates were significantly correlated with initial return of spontaneous circulation (mean chest compression rates for initial survivors and nonsurvivors, 90±17 and 79±18 cpm, respectively; P =0.0033). Conclusions— In-hospital chest compression rates were below published resuscitation recommendations, and suboptimal compression rates in our study correlated with poor return of spontaneous circulation. CPR quality is likely a critical determinant of survival after cardiac arrest, suggesting the need for routine measurement, monitoring, and feedback systems during actual resuscitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peberdy, M. A., Kaye, W., Ornato, J. P., Larkin, G. L., Nadkarni, V., Mancini, M. E., Berg, R. A., Nichol, G., & Lane-Trultt, T. (2003) · Resuscitation · doi:10.1016/s0300-9572(03)00215-6 · Cited by 1,242
Hyperventilation-Induced Hypotension During Cardiopulmonary Resuscitation
Aufderheide, T. P., Sigurdsson, G., Pirrallo, R. G., Yannopoulos, D., McKnite, S., von Briesen, C., Sparks, C. W., Conrad, C. J., Provo, T. A., & Lurie, K. G. (2004) · Circulation · doi:10.1161/01.cir.0000126594.79136.61 · Cited by 886
Cobb, L. A. (1999) · JAMA · doi:10.1001/jama.281.13.1182 · Cited by 730
Berg, R. A., Sanders, A. B., Kern, K. B., Hilwig, R. W., Heidenreich, J. W., Porter, M. E., & Ewy, G. A. (2001) · Circulation · doi:10.1161/hc4501.098926 · Cited by 715
Wik, L., Hansen, T. B., Fylling, F., Steen, T., Vaagenes, P., Auestad, B. H., & Steen, P. A. (2003) · JAMA · doi:10.1001/jama.289.11.1389 · Cited by 646
Eftestøl, T., Sunde, K., & Steen, P. A. (2002) · Circulation · doi:10.1161/01.cir.0000016362.42586.fe · Cited by 463
(1980) · Injury · doi:10.1016/0020-1383(80)90153-9 · Cited by 429
Eisenberg, M. S., & Mengert, T. J. (2001) · New England Journal of Medicine · doi:10.1056/nejm200104263441707 · Cited by 426
Kern, K. B. (1992) · Archives of Internal Medicine · doi:10.1001/archinte.152.1.145 · Cited by 228
The epidemiology of out-of-hospital ‘sudden’ cardiac arrest
Engdahl, J., Holmberg, M., Karlson, B. W., Luepker, R., & Herlitz, J. (2002) · Resuscitation · doi:10.1016/s0300-9572(01)00464-6 · Cited by 216
Efficacy of chest compression-only BLS CPR in the presence of an occluded airway
Kern, K. B., Hilwig, R., Berg, R. A., & Ewy, G. A. (1998) · Resuscitation · doi:10.1016/s0300-9572(98)00141-5 · Cited by 213
Cardiac Arrest: The Science and Practice of Resuscitation Medicine
(1996) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.1996.tb03381.x · Cited by 189
Resuscitation in Europe: a tale of five European regions
Herlitz, J., Bahr, J., Fischer, M., Kuisma, M., Lexow, K., & Thorgeirsson, G. (1999) · Resuscitation · doi:10.1016/s0300-9572(99)00045-3 · Cited by 179
Feneley, M. P., Maier, G. W., Kern, K. B., Gaynor, J. W., Gall, S. A., Sanders, A. B., Raessler, K., Muhlbaier, L. H., Rankin, J. S., & Ewy, G. A. (1988) · Circulation · doi:10.1161/01.cir.77.1.240 · Cited by 178
Sanders, A. B., Kern, K. B., Berg, R. A., Hilwig, R. W., Heidenrich, J., & Ewy, G. A. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.129507 · Cited by 174
Babbs, C. F., Voorhees, W. D., FITZGERALD, K. R., Holmes, H. R., & Geddes, L. A. (1983) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(83)80290-x · Cited by 155
Quality of Survival After Cardiopulmonary Resuscitation
de Vos, R., de Haes, J. C. J. M., Koster, R. W., & de Haan, R. J. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.3.249 · Cited by 145
Dumot, J. A., Burval, D. J., Šprung, J., Waters, J. H., Mraović, B., Karafa, M., Mascha, E. J., & Bourke, D. L. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.14.1751 · Cited by 131
Temporal Patterns in Long-Term Survival After Resuscitation From Out-of-Hospital Cardiac Arrest
Rea, T. D., Crouthamel, M. R., Eisenberg, M. S., Becker, L., & Lima, A. R. (2003) · Circulation · doi:10.1161/01.cir.0000087403.24467.a4 · Cited by 97
Self-citationOut-of-hospital quantitative monitoring of end-tidal carbon dioxide pressure during CPR
White, R. D., & Asplin, B. R. (1994) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(94)70003-6 · Cited by 51
Cited by
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Panchal, A. R., Bartos, J. A., Cabañas, J. G., Donnino, M. W., Drennan, I. R., Hirsch, K. G., Kudenchuk, P. J., Kurz, M. C., Lavonas, E. J., Morley, P. T., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000916 · Cited by 2,105
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
European Resuscitation Council Guidelines for Resuscitation 2015
Soar, J., Nolan, J. P., Böttiger, B. W., Perkins, G. D., Lott, C., Carli, P., Pellis, T., Sandroni, C., Skrifvars, M. B., Smith, G. B., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.016 · Cited by 1,503
Callaway, C. W., Soar, J., Aibiki, M., Böttiger, B. W., Brooks, S. C., Deakin, C. D., Donnino, M. W., Drajer, S., Kloeck, W., Morley, P. T., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000273 · Cited by 1,390
Metadata
- Authors
- Abella, B. S., Sandbo, N., Vassilatos, P., Alvarado, J. P., O’Hearn, N., Wigder, H. N., Hoffman, P., Tynus, K., Vanden Hoek, T. L., & Becker, L. B.
- Venue
- Circulation
- Published
- 2005-02
- Volume
- 111
- Issue
- 4
- Pages
- 428-434
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2164130359
- Cited by
- 689
- References
- 20
- FWCI
- 40.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.