Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 205

The DOI matches its Crossref record.

Modification of the Substrate for Maintenance of Idiopathic Human Atrial Fibrillation: Efficacy of Radiofrequency Ablation Using Nonfluoroscopic Catheter Guidance

Ernst, Sabine, Schlüter, Michael, Ouyang, Feifan, Khanedani, Afsaneh, Cappato, Riccardo, Hebe, Joachim, Volkmer, Marius, Antz, Matthias, Kuck, Karl-Heinz·1999·Circulation

Abstract

Background —Catheter ablative techniques to modify the substrate to maintain atrial fibrillation (AF) require the creation of continuous radiofrequency current-induced ablation lines. This study was designed to assess the efficacy and safety of nonfluoroscopic mapping in this setting. Methods and Results —A total of 45 consecutive patients with idiopathic AF were studied. The first 13 underwent ablation confined to the left atrium by creating a circular line isolating the pulmonary vein ostia and a second line connecting the former with the mitral annulus. Subsequently, 12 of these patients underwent a procedure confined to the right atrium (RA), where attempts were made to create an isthmus line between the inferior vena cava and the tricuspid annulus, an anterior line connecting the tricuspid annulus with the superior vena cava, and an intercaval line between the ostia of the inferior and superior venae cavae. In the last 32 patients, only the RA approach was performed. Technical difficulties prevented the creation of the intended left atrial line pattern: all patients experienced recurrences. A 100% recurrence rate was also observed after subsequent RA ablation, despite creation of a complete line pattern in 4 of 12 patients. Of the final 32 patients, AF recurred in 94%; a complete ablation line pattern had been achieved in 18 patients (56%), 16 of whom had recurrences. Conclusions —The electroanatomically-guided creation of extended radiofrequency current lesions is technically feasible only in the RA. However, procedural success in the RA does not suppress recurrences of AF in the majority of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.100.20.2085

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 205

Metadata

Authors
Ernst, S., Schlüter, M., Ouyang, F., Khanedani, A., Cappato, R., Hebe, J., Volkmer, M., Antz, M., & Kuck, K.-H.
Venue
Circulation
Published
1999-11-16
Volume
100
Issue
20
Pages
2085-2092
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2046665680
Cited by
205
References
0
FWCI
13.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modification of the Substrate for Maintenance of Idiopathic Human Atrial Fibrillation: Efficacy of Radiofrequency Ablation Using Nonfluoroscopic Catheter Guidance. https://app.cochat.ai/papers/10.1161/01.cir.100.20.2085
The paper
Ernst, S., Schlüter, M., Ouyang, F., Khanedani, A., Cappato, R., Hebe, J., Volkmer, M., Antz, M., & Kuck, K.-H. (1999). Modification of the Substrate for Maintenance of Idiopathic Human Atrial Fibrillation: Efficacy of Radiofrequency Ablation Using Nonfluoroscopic Catheter Guidance. Circulation. https://doi.org/10.1161/01.cir.100.20.2085

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.