Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 751

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Technique and Results of Linear Ablation at the Mitral Isthmus

Jaïs, Pierre, Hocini, Mélèze, Hsu, Li-Fern, Sanders, Prashanthan, Scavee, Christophe, Weerasooriya, Rukshen, Macle, Laurent, Raybaud, Florence, Garrigue, Stéphane, Shah, Dipen C., Le Metayer, Philippe, Clémenty, Jacques, Haïssaguerre, Michel·2004·Circulation

Abstract

Background— This prospective clinical study evaluates the feasibility and efficacy of combined linear mitral isthmus ablation and pulmonary vein (PV) isolation in patients with paroxysmal atrial fibrillation (AF). Methods and Results— One hundred consecutive patients (13 women; age 55±10 years) with drug-refractory, symptomatic paroxysmal AF underwent PV isolation and linear ablation of the cavotricuspid isthmus and the mitral isthmus (lateral mitral annulus to the left inferior PV). They were compared with 100 consecutive patients (14 women; age, 52±10 years) undergoing PV isolation and cavotricuspid ablation without mitral isthmus ablation. Bidirectional mitral isthmus block was confirmed by demonstrating (1) a parallel corridor of double potentials during coronary sinus (CS) pacing, (2) an activation detour by pacing either side of the line, and (3) differential pacing techniques. Isolation of all PVs and cavotricuspid isthmus ablation were performed successfully in all. Mitral isthmus block was achieved in 92 patients after 20±10 minutes of endocardial radiofrequency application and an additional 5±4 minutes of epicardial radiofrequency application from within the CS in 68, resulting in a conduction delay of 151±26 ms during CS pacing. Thirty-two patients with mitral isthmus ablation compared with 49 without had recurrent atrial arrhythmia ( P =0.02) requiring further ablation. At 1 year after the last procedure, 87 patients with mitral isthmus ablation and 69 without ( P =0.002) were arrhythmia free without antiarrhythmic drugs, mitral isthmus ablation being the only factor associated with long-term success (RR for AF recurrence, 0.2; CI, 0.1 to 0.4; P <0.001). Conclusions— Catheter ablation of the mitral isthmus results consistently in demonstrable conduction block and is associated with a high cure rate for paroxysmal AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.0000146917.75041.58

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 751

Metadata

Authors
Jaïs, P., Hocini, M., Hsu, L.-F., Sanders, P., Scavee, C., Weerasooriya, R., Macle, L., Raybaud, F., Garrigue, S., Shah, D. C., Le Metayer, P., Clémenty, J., & Haïssaguerre, M.
Venue
Circulation
Published
2004-11-09
Volume
110
Issue
19
Pages
2996-3002
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2117470639
Cited by
751
References
2
FWCI
25.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Technique and Results of Linear Ablation at the Mitral Isthmus. https://app.cochat.ai/papers/10.1161/01.cir.0000146917.75041.58
The paper
Jaïs, P., Hocini, M., Hsu, L.-F., Sanders, P., Scavee, C., Weerasooriya, R., Macle, L., Raybaud, F., Garrigue, S., Shah, D. C., Le Metayer, P., Clémenty, J., & Haïssaguerre, M. (2004). Technique and Results of Linear Ablation at the Mitral Isthmus. Circulation. https://doi.org/10.1161/01.cir.0000146917.75041.58

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.