Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background —The extent of ostial ablation necessary to electrically disconnect the pulmonary vein (PV) myocardial extensions that initiate atrial fibrillation from the left atrium has not been determined. Methods and Results —Seventy patients underwent PV mapping with a circumferential 10-electrode catheter during sinus rhythm or left atrial pacing. After assessment of perimetric distribution and activation sequence of PV potentials, ostial ablation was performed at segments showing earliest activation, with the end point of PV disconnection. A total of 162 PVs (excluding right inferior PVs) were ablated. PV potentials were present at 60% to 88% of their perimeter, but PV muscle activation was always sequential from a segment with earliest activation (breakthrough). Radiofrequency (RF) application at this breakthrough eliminated all PV potentials in 34 PVs, whereas a secondary breakthrough required RF applications at separate segments in 77; in others, >2 segments were ablated. A median of 5, 6, and 4 bipoles from the circular catheter were targeted in the right superior, left superior, and inferior PVs, respectively, to achieve PV disconnection. Early recurrence of arrhythmia was observed in 31 patients as a result of new venous or atrial foci or recovery of previously targeted PVs, most related to a single recovered breakthrough that was reablated with local RF application. Conclusions —Although PV muscle covers a large extent of the PV perimeter, there are specific breakthroughs from the left atrium that allow ostial PV disconnection by use of partial perimetric ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
Haïssaguerre, M., Jaïs, P., Shah, D. C., Garrigue, S., Takahashi, A., Lavergne, T., Hocini, M., Peng, J. T., Roudaut, R., & Clémenty, J. (2000) · Circulation · doi:10.1161/01.cir.101.12.1409 · Cited by 922
Self-citationPulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation
Robbins, I. M., Colvin, E. V., Doyle, T. P., Kemp, W. E., Loyd, J. E., McMahon, W. S., & Kay, G. N. (1998) · Circulation · doi:10.1161/01.cir.98.17.1769 · Cited by 443
Electrical properties of the thoracic veins
Zipes, D. P., & Knope, R. F. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90533-4 · Cited by 126
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationFuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.009 · Cited by 1,158
Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation
Oral, H., Knight, B. P., Tada, H., Özaydın, M., Chugh, A., Hassan, S., Scharf, C., Lai, S. W. K., Greenstein, R., Pelosi, F., et al. (2002) · Circulation · doi:10.1161/hc0902.104712 · Cited by 1,112
Metadata
- Authors
- Haïssaguerre, M., Shah, D. C., Jaïs, P., Hocini, M., Yamane, T., Deisenhofer, I., Chauvin, M., Garrigue, S., & Clémenty, J.
- Venue
- Circulation
- Published
- 2000-11-14
- Volume
- 102
- Issue
- 20
- Pages
- 2463-2465
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2139011872
- Cited by
- 952
- References
- 4
- FWCI
- 32.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.