The DOI matches its Crossref record.
Cardiac Output and Central Distribution of Blood Flow in the Human Fetus
Open accessAbstract
Background —The objectives of this study were to establish reference ranges for left and right cardiac output and to investigate blood flow distribution through the foramen ovale, ductus arteriosus, and pulmonary bed in human fetuses. Methods and Results —A prospective study was performed in 222 normal fetuses from 13 to 41 weeks of gestation with high-resolution color Doppler ultrasound. Cardiac output and ductal flow were calculated by use of vessel diameter and the time-velocity integral. Pulmonary blood flow was expressed as the difference between right cardiac output and ductal flow. Foramen ovale flow was estimated as the difference between pulmonary flow and left cardiac output. Gestational age–specific reference ranges are given for left, right, and biventricular output and volume of ductal blood flow, showing an exponential increase with gestational age. Median ratio of right to left cardiac output was 1.42 and was not associated with gestational age. Right cardiac output was 59% and left cardiac output was 41% of biventricular cardiac output. Median biventricular cardiac output was estimated to be 425 mL · min −1 · kg −1 fetal weight. Ductal blood flow was 46%, estimated pulmonary flow was 11%, and estimated foramen ovale flow was 33% of biventricular output. Conclusions —The study establishes reference ranges for fetal cardiac output and offers insights into the central blood flow distribution in human fetuses from 13 weeks to term. There is a clear right heart dominance. The estimated ratio of pulmonary blood flow to cardiac output is higher than in fetal lamb studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Prsa, M., Sun, L., van Amerom, J., Yoo, S.-J., Grosse-Wortmann, L., Jaeggi, E., Macgowan, C., & Seed, M. (2014) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.001859 · Cited by 168
Cardiac output and blood flow volume redistribution during acute maternal hypoxia in fetal sheep
Tchirikov, M., Strohner, M., & Scholz, A. (2010) · Journal of Perinatal Medicine · doi:10.1515/jpm.2010.053 · Cited by 14
Metadata
- Authors
- Mielke, G., & Benda, N.
- Venue
- Circulation
- Published
- 2001-03-27
- Volume
- 103
- Issue
- 12
- Pages
- 1662-1668
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1986569614
- Cited by
- 345
- References
- 0
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac Output and Central Distribution of Blood Flow in the Human Fetus. https://app.cochat.ai/papers/10.1161/01.cir.103.12.1662
- The paper
- Mielke, G., & Benda, N. (2001). Cardiac Output and Central Distribution of Blood Flow in the Human Fetus. Circulation. https://doi.org/10.1161/01.cir.103.12.1662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.