Maximal Treadmill Stress Testing for Cardiovascular Evaluation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Experience with a maximal treadmill stress testing procedure which is relatively safe, simple, and reproducible is reported. It has been used in normal persons and cardiac patients with ages ranging from 7 to 83 years. There have been no deaths in our total experience of 4,028 maximal capacity stress tests. Maximal capacity is predicted by the patient's peak predicted pulse rate. Sixty-three per cent of those with ischemic S-T segments did not experience pain of any type.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Relation of Heart Rate and Systolic Blood Pressure to the Onset of Pain in Angina Pectoris
ROBINSON, B. F. (1967) · Circulation · doi:10.1161/01.cir.35.6.1073 · Cited by 566
Maximal heart rate during work in older men
Åstrand, I., Åstrand, P.-O., & Rodahl, K. (1959) · Journal of Applied Physiology · doi:10.1152/jappl.1959.14.4.562 · Cited by 57
The physiologic fallacy of adjusting for body weight in performance of the Master two-step test
Rowell, L. B., TAYLOR, H. L., Simonson, E., et al. (1965) · American Heart Journal · doi:10.1016/0002-8703(65)90357-1 · Cited by 27
Cited by
A comparative analysis of four protocols for maximal treadmill stress testing
Pollock, M. L., Bohannon, R. L., Cooper, K. H., Ayres, J. J., Ward, A., White, S. R., & Linnerud, A. C. (1976) · American Heart Journal · doi:10.1016/s0002-8703(76)80401-2 · Cited by 536
Comparison of the ramp versus standard exercise protocols
Myers, J., Buchanan, N., Walsh, D., Kraemer, M., McAuley, P., Hamilton-Wessler, M., & Froelicher, V. F. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80144-5 · Cited by 536
Ellestad, M. H., & Wan, M. K. (1975) · Circulation · doi:10.1161/01.cir.51.2.363 · Cited by 459
Self-citationBruce treadmill test in children: Normal values in a clinic population
Gumming, G. R., Everatt, D., & Hastman, L. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90134-0 · Cited by 372
Beltz, N. M., Gibson, A. L., Janot, J. M., Kravitz, L., Mermier, C. M., & Dalleck, L. C. (2016) · Journal of Sports Medicine · doi:10.1155/2016/3968393 · Cited by 306
Blood Pressure Behaviour During Physical Activity
Palatini, P. (1988) · Sports Medicine · doi:10.2165/00007256-198805060-00002 · Cited by 77
(2022) · International Journal of Exercise Science · doi:10.70252/nhay2400 · Cited by 3
Metadata
- Authors
- ELLESTAD, M. H., ALLEN, W., WAN, M. C. K., & KEMP, G. L.
- Venue
- Circulation
- Published
- 1969-04
- Volume
- 39
- Issue
- 4
- Pages
- 517-522
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2021170227
- Cited by
- 171
- References
- 3
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.