The First Derivative Thoracic Impedance Cardiogram
Open accessThe DOI matches its Crossref record.
Abstract
When an alternating current of high frequency is applied to the thorax, the first derivative of the impedance to this current is affected by the cardiac cycle resulting in a characteristic wave form. Phonocardiograms, electrocardiograms, and first derivative thoracic impedance cardiograms were recorded simultaneously in 91 subjects. The first derivative thoracic impedance cardiograms were found to have sharply demarcated points which occur synchronously with the first heart sound, aortic second sound, pulmonic second sound, mitral opening snap, third heart sound, and fourth heart sound. The first derivative thoracic impedance cardiogram may thus be used not only as a reference tracing to help identify heart sounds on the phonocardiogram, but also for directly timing the intervals within the cardiac cycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Methodological Guidelines for Impedance Cardiography
Sherwood(Chair), A., Allen, M. T., Fahrenberg, J., Kelsey, R. M., Lovallo, W. R., & van Doornen, L. J. P. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb02171.x · Cited by 1,169
Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressure
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00657.2005 · Cited by 418
“Bioimpedance has previously been validated for determination of systolic time intervals (17), and the NCCOM3 device has itself been compared favorably with both echocardiography (16) and mechanophonocardiography (35).”
ResultCardiovascular Regulation during Water Immersion.
Sik Park, K., Kyu Choi, J., & Saeng Park, Y. (1999) · APPLIED HUMAN SCIENCE Journal of Physiological Anthropology · doi:10.2114/jpa.18.233 · Cited by 174
“Point B and point X have been confirmed to coincide with the opening and closing of the aortic valve in phonocardiographical and echocardiographical studies (Lababidi et al., 1970; Miles and Gotshall, 1989).”
BackgroundPandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114
“…S2 primary heart sounds used here to describe features or components of the SCG signal are consistent with literature on phonocardiography (e.g., Lababidi et al 1970), it may be noted that the SCGderived S1 and S2 components, while concurrent in time with the S1 and S2 heart sound components…”
Result
Metadata
- Authors
- LABABIDI, Z., EHMKE, D. A., DURNIN, R. E., LEAVERTON, P. E., & LAUER, R. M.
- Venue
- Circulation
- Published
- 1970-04
- Volume
- 41
- Issue
- 4
- Pages
- 651-658
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2021655920
- Cited by
- 193
- References
- 0
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.