Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer

Pandia, Keya, Inan, Omer T, Kovacs, Gregory T A, Giovangrandi, Laurent·2012·Physiological Measurement

Abstract

Seismocardiography (SCG) is a non-invasive measurement of the vibrations of the chest caused by the heartbeat. SCG signals can be measured using a miniature accelerometer attached to the chest, and are thus well-suited for unobtrusive and long-term patient monitoring. Additionally, SCG contains information relating to both cardiovascular and respiratory systems. In this work, algorithms were developed for extracting three respiration-dependent features of the SCG signal: intensity modulation, timing interval changes within each heartbeat, and timing interval changes between successive heartbeats. Simultaneously with a reference respiration belt, SCG signals were measured from 20 healthy subjects and a respiration rate was estimated using each of the three SCG features and the reference signal. The agreement between each of the three accelerometer-derived respiration rate measurements was computed with respect to the respiration rate derived from the reference respiration belt. The respiration rate obtained from the intensity modulation in the SCG signal was found to be in closest agreement with the respiration rate obtained from the reference respiration belt: the bias was found to be 0.06 breaths per minute with a 95% confidence interval of -0.99 to 1.11 breaths per minute. The limits of agreement between the respiration rates estimated using SCG (intensity modulation) and the reference were within the clinically relevant ranges given in existing literature, demonstrating that SCG could be used for both cardiovascular and respiratory monitoring. Furthermore, phases of each of the three SCG parameters were investigated at four instances of a respiration cycle-start inspiration, peak inspiration, start expiration, and peak expiration-and during breath hold (apnea). The phases of the three SCG parameters observed during the respiration cycle were congruent with existing literature and physiologically expected trends.

Integrity signals

Registry

Crossref · 10.1088/0967-3334/33/10/1643

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Pandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L.
Affiliations
  • Stanford University (US)
  • Stanford Medicine (US)
Corresponding author
Pandia, Keya
Venue
Physiological Measurement
Published
2012-09-18
Volume
33
Issue
10
Pages
1643-1660
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2079084424
Cited by
114
References
32
Citations by year
2026: 8 · 2025: 6 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 12 · 2020: 17 · 2019: 13 · 2018: 3 · 2017: 5 · 2016: 9 · 2015: 5 · 2014: 10 · 2013: 3
FWCI
3.28
Type
journal article
Language
en
Open access
closed
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
seismocardiography, respiratory rate estimation, accelerometer, chest vibration, intensity modulation, apnea, long-term patient monitoring, cardiovascular monitoring, non-invasive monitoring
MeSH terms
Adult, Apnea, Arrhythmia, Sinus, Female, Heart Function Tests, Heart Rate, Humans, Kinetocardiography, Male, Middle Aged, Miniaturization, Quality Control, Respiration, Signal Processing, Computer-Assisted, Thorax, Time Factors, Vibration, Young Adult, Respiratory Rate, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review