Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer
Abstract
Seismocardiography (SCG) is a non-invasive measurement of the vibrations of the chest caused by the heartbeat. SCG signals can be measured using a miniature accelerometer attached to the chest, and are thus well-suited for unobtrusive and long-term patient monitoring. Additionally, SCG contains information relating to both cardiovascular and respiratory systems. In this work, algorithms were developed for extracting three respiration-dependent features of the SCG signal: intensity modulation, timing interval changes within each heartbeat, and timing interval changes between successive heartbeats. Simultaneously with a reference respiration belt, SCG signals were measured from 20 healthy subjects and a respiration rate was estimated using each of the three SCG features and the reference signal. The agreement between each of the three accelerometer-derived respiration rate measurements was computed with respect to the respiration rate derived from the reference respiration belt. The respiration rate obtained from the intensity modulation in the SCG signal was found to be in closest agreement with the respiration rate obtained from the reference respiration belt: the bias was found to be 0.06 breaths per minute with a 95% confidence interval of -0.99 to 1.11 breaths per minute. The limits of agreement between the respiration rates estimated using SCG (intensity modulation) and the reference were within the clinically relevant ranges given in existing literature, demonstrating that SCG could be used for both cardiovascular and respiratory monitoring. Furthermore, phases of each of the three SCG parameters were investigated at four instances of a respiration cycle-start inspiration, peak inspiration, start expiration, and peak expiration-and during breath hold (apnea). The phases of the three SCG parameters observed during the respiration cycle were congruent with existing literature and physiologically expected trends.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904 · see citing works
A Simple Sequentially Rejective Multiple Test Procedure
(1979) · Scandinavian Journal of Statistics · doi:10.2307/4615733 · Cited by 21,526 · see citing works
A NEW MEASURE OF RANK CORRELATION
Kendall, M. G. (1938) · Biometrika · doi:10.1093/biomet/30.1-2.81 · Cited by 7,299 · see citing works
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539 · see citing works
Communication In The Presence Of Noise
Shannon, C. E. (1998) · Proceedings of the IEEE · doi:10.1109/jproc.1998.659497 · Cited by 4,815 · see citing works
Certain Topics in Telegraph Transmission Theory
Nyquist, H. (1928) · Transactions of the American Institute of Electrical Engineers · doi:10.1109/t-aiee.1928.5055024 · Cited by 3,134 · see citing works
BERNTSON, G. G., CACIOPPO, J. T., & QUIGLEY, K. S. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb01731.x · Cited by 998 · see citing works
Madden, H. H. (1978) · Analytical Chemistry · doi:10.1021/ac50031a048 · Cited by 746 · see citing works
Reflex Control of the Circulation
Zucker, I. H., & Gilmore, J. P. (2020) · CRC Press eBooks · doi:10.1201/9780367813338 · Cited by 234 · see citing works
A human cardiopulmonary system model applied to the analysis of the Valsalva maneuver
Lu, K., Clark, J. W., Ghorbel, F. H., Ware, D. L., & Bidani, A. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.281.6.h2661 · Cited by 218 · see citing works
Optimal wavelet denoising for phonocardiograms
Messer, S. R., Agzarian, J., & Abbott, D. (2001) · Microelectronics Journal · doi:10.1016/s0026-2692(01)00095-7 · Cited by 215 · see citing works
The First Derivative Thoracic Impedance Cardiogram
Lababidi, Z. A., Ehmke, D. A., Durnin, R. E., Leaverton, P. E., & Lauer, R. M. (1970) · Circulation · doi:10.1161/01.cir.41.4.651 · Cited by 192 · see citing works
Castiglioni, P., Faini, A., Parati, G., & Rienzo, M. D. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353199 · Cited by 156 · see citing works
Seismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149 · see citing works
Non-contact respiratory rate measurement validation for hospitalized patients
Droitcour, A. D., Seto, T. B., Park, B.-K., Yamada, S., Vergara, A., Hourani, C. E., Shing, T., Yuen, A., Lubecke, V. M., & Boric-Lubecke, O. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332635 · Cited by 135 · see citing works
An Accelerometer-Based Device for Sleep Apnea Screening
Morillo, D., Ojeda, J. L. R., Foix, L. F. C., & Jiménez, A. L. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2027231 · Cited by 129 · see citing works
Variation of respiratory sinus arrhythmia with age
Hellman, J., & Stacy, R. W. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.41.5.734 · Cited by 127 · see citing works
Measurement of respiratory rate with high-resolution accelerometer and emfit pressure sensor
Reinvuo, T., Hannula, M., Sorvoja, H. S. S., et al. (2006) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2006.1634270 · Cited by 108 · see citing works
Hemodynamic Determinants of the Amplitude of the First Heart Sound
Sakamoto, T., Kusukawa, R., MacCanon, D. M., Luisada, A. A., & Harvey, I. (1965) · Circulation Research · doi:10.1161/01.res.16.1.45 · Cited by 105 · see citing works
Seismocardiography: a technique for recording precordial acceleration
Zanetti, J. M., & Salerno, D. M. (2002) · doi:10.1109/cbms.1991.128936 · Cited by 103 · see citing works
Cysarz, D., Zerm, R., Bettermann, H., Frühwirth, M., Moser, M., & Kröz, M. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9580-2 · Cited by 92 · see citing works
Motion artifact cancellation to obtain heart sounds from a single chest-worn accelerometer
Pandia, K., Ravindran, S., Cole, R., et al. (2010) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2010.5495553 · Cited by 69 · see citing works
Self-citationRight and left ventricular systolic time intervals
Leighton, R. F., Weissler, A. M., Weinstein, P. B., & Wooley, C. F. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90084-1 · Cited by 60 · see citing works
Respiratory rate measurement in adults—how reliable is it?
Lim, W. S., CARTY, S. M., Macfarlane, J. T., et al. (2002) · Respiratory Medicine · doi:10.1053/rmed.2001.1203 · Cited by 55 · see citing works
Improvement of ballistocardiogram processing by inclusion of respiration information
Tavakolian, K., Vaseghi, A., & Kamińska, B. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/7/006 · Cited by 50 · see citing works
Hemodynamic determinants of the amplitude of the second heart sound.
Kusukawa, R., Bruce, D. W., Sakamoto, T., et al. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.3.938 · Cited by 39 · see citing works
Respiratory modulation of heart sound morphology
Amit, G., Shukha, K., Gavriely, N., et al. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00806.2008 · Cited by 33 · see citing works
Infrasonic cardiac signals: Complementary windows to cardiovascular dynamics
Tavakolian, K., Ngai, B., Blaber, A. P., & Kamińska, B. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091061 · Cited by 25 · see citing works
Agress, C. M., Fields, L. G., WEGNER, S., et al. (1961) · The American Journal of Cardiology · doi:10.1016/0002-9149(61)90175-8 · Cited by 22 · see citing works
Estimating heart rate and RSA from the mattress‐recorded kinetocardiogram
Woodward, S. H., Arsenault, N. J., Voelker, K., et al. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2007.00526.x · Cited by 18 · see citing works
The synchrony between baroreflex sequences and cardio-respiratory activity
Vallais, F., Lucini, D., Pagani, M., et al. (2008) · Computers in cardiology · doi:10.1109/cic.2008.4749165 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775 · see citing works
Self-citationHa, T., Tran, J., Liu, S., Jang, H., Jeong, H., Mitbander, R., Huh, H., Qiu, Y., Duong, J., Wang, R. L., et al. (2019) · Advanced Science · doi:10.1002/advs.201900290 · Cited by 220 · see citing works
Etemadi, M., Inan, O. T., Heller, J. A., Hersek, S., Klein, L., & Roy, S. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2405480 · Cited by 95 · see citing works
“S EISMOCARDIOGRAPHY is a non-invasive technique based on measuring the micro-vibrations of the chest wall for assessing left ventricular function [1]–[4], systolic and diastolic time intervals [5]–[7], and cardio-respiratory interactions [8].”
Self-citationNon-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients
Semiz, B., Carek, A. M., Johnson, J. C., Ahmad, S., Heller, J. A., Vicente, F. G., Caron, S., Hogue, C. W., Etemadi, M., & Inan, O. T. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3032938 · Cited by 35 · see citing works
Self-citation
- Authors
- Pandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L.
- Affiliations
- Stanford University (US)
- Stanford Medicine (US)
- Corresponding author
- Pandia, Keya
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-09-18
- Volume
- 33
- Issue
- 10
- Pages
- 1643-1660
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2079084424
- Cited by
- 114
- References
- 32
- Citations by year
- 2026: 8 · 2025: 6 · 2024: 6 · 2023: 5 · 2022: 12 · 2021: 12 · 2020: 17 · 2019: 13 · 2018: 3 · 2017: 5 · 2016: 9 · 2015: 5 · 2014: 10 · 2013: 3
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physiological Measurement (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- seismocardiography, respiratory rate estimation, accelerometer, chest vibration, intensity modulation, apnea, long-term patient monitoring, cardiovascular monitoring, non-invasive monitoring
- MeSH terms
- Adult, Apnea, Arrhythmia, Sinus, Female, Heart Function Tests, Heart Rate, Humans, Kinetocardiography, Male, Middle Aged, Miniaturization, Quality Control, Respiration, Signal Processing, Computer-Assisted, Thorax, Time Factors, Vibration, Young Adult, Respiratory Rate, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review