Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 174

The DOI matches its Crossref record.

Systemic and regional hemodynamics in low, normal and high cardiac output borderline hypertension.

Open access
Messerli, F H, De Carvalho, J G, Christie, B, Frohlich, E D · 1978 · Circulation

Abstract

Forty-one patients with borderline hypertension were subdivided into groups with low, normal, and high car- diac index.Cardiac output, intra-arterial pressure, renal blood flow, splanchnic blood flow, plasma volume, red cell mass and plasma renin activity were determined concomitantly, and derived hemodynamic indices were calculated.Cardiac output, arterial pressure and plasma renin activity were also measured after head-up tilt and isometric handgrip.Heart rate and stroke index were significantly higher in patients with normal and high cardiac output than in patients with low cardiac output.A significant difference was also found between the three groups in total blood volume, total peripheral resistance, renal and hepatic blood flow, whereas plasma renin activity and plasma volume did not differ significantly.Cardiac output cor- related with plasma (r = 0.500), total blood (r = 0.630) and central blood volumes (r = 0.782).In contrast, a negative cor- relation was observed between total peripheral resistance, plasma (r = -0.440)and total blood (r =-0.644) volumes.Furthermore, cardiac output, renal (r = 0.550) and hepatic (r = 0.625) blood flows correlated.The response of cardiac out- put and total peripheral resistance to tilt was more pronounced in high than in low cardiac output borderline hypertension (P < 0.05) whereas handgrip responses were similar in the three groups.We conclude that the fluid volume state is a major determinant of cardiac output and/or peripheral resistance in borderline hypertension with renal and hepatic blood flow varying in parallel.The magnitude of cardiac output, renal and hepatic blood flow depends mainly on the shift of the cir- culating blood volume to the central circulation.THE EARLY DEVELOPMENTAL STAGE OF ESSENTIAL HYPERTENSION has been described in various terms, including labile, juvenile, borderline and hyperkinetic high blood pressure.The common denominator of the definition is that all imply relatively young patients in whom alternatively nor- mal and elevated arterial pressures can be measured.Although different criteria for defining borderline hypertension have been used by various investigators,

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.58.3.441

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Messerli, F. H., De Carvalho, J. G., Christie, B., & Frohlich, E. D.
Venue
Circulation
Published
1978-09
Volume
58
Issue
3
Pages
441-448
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2061732868
Cited by
174
References
0
FWCI
7.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systemic and regional hemodynamics in low, normal and high cardiac output borderline hypertension. https://app.cochat.ai/papers/10.1161/01.cir.58.3.441
The paper
Messerli, F. H., De Carvalho, J. G., Christie, B., & Frohlich, E. D. (1978). Systemic and regional hemodynamics in low, normal and high cardiac output borderline hypertension. Circulation. https://doi.org/10.1161/01.cir.58.3.441

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.