The DOI matches its Crossref record.
Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance.
Abstract
Dramatic changes in the shape of pulsatile ascending aortic pressure and flow wave forms occur during the Valsalva maneuver in man. To study these changes, aortic pressure and flow signals were recorded in eight patients using a multisensor catheter. Aortic input impedance was derived during the control, strain and postrelease phases of the Valsalva maneuver. During control, well-defined minima and maxima occurred in the spectral plots of impedance moduli. This pattern was accentuated during the postrelease phase. In contrast, input impedance during strain was almost equal to the characteristic impedance for all harmonics. These results imply that during the control and postrelease phases, strong reflections return to the ascending aorta, but during the strain phase, reflections are minimal, absent or more diffuse. From wave transmission theory, it also follows that pulsatile pressure and flow wave forms should be similar in shape in the absence of reflections and dissimilar in the presence of reflections. This was observed in all eight patients. By provoking changes in the arterial tree during the Valsalva maneuver, the magnitude and timing of wave reflections were significantly altered, resulting in marked changes in the shape of pulsatile aortic pressure and flow wave forms. This study demonstrates the importance of reflections in determining the shape of the arterial pulse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454
Self-citationChen, C.-H., Ting, C.-T., Nussbacher, A., Nevo, E., Kass, D. A., Pak, P., Wang, S.-P., Chang, M.-S., & Yin, F. C. P. (1996) · Hypertension · doi:10.1161/01.hyp.27.2.168 · Cited by 401
Does Radial Artery Pressure Accurately Reflect Aortic Pressure?
Pauca, A. L., Wallenhaupt, S. L., Kon, N. D., & Tucker, W. Y. (1992) · Chest · doi:10.1378/chest.102.4.1193 · Cited by 341
Quantification of Wave Reflection in the Human Aorta From Pressure Alone: A Proof of Principle
Westerhof, B. E., Guelen, I., Westerhof, N., Karemaker, J. M., & Avolio, A. (2006) · Hypertension · doi:10.1161/01.hyp.0000238330.08894.17 · Cited by 309
Self-citationSaba, P. S., Roman, M. J., Pini, R., Spitzer, M., Ganau, A., & Devereux, R. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90772-s · Cited by 266
Metadata
- Authors
- Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A.
- Venue
- Circulation
- Published
- 1981-01
- Volume
- 63
- Issue
- 1
- Pages
- 122-132
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2113126003
- Cited by
- 175
- References
- 0
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance. https://app.cochat.ai/papers/10.1161/01.cir.63.1.122
- The paper
- Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1981). Manipulation of ascending aortic pressure and flow wave reflections with the Valsalva maneuver: relationship to input impedance. Circulation. https://doi.org/10.1161/01.cir.63.1.122
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.