The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Quantification of Wave Reflection in the Human Aorta From Pressure Alone: A Proof of Principle
Abstract
Wave reflections affect the proximal aortic pressure and flow waves and play a role in systolic hypertension. A measure of wave reflection, receiving much attention, is the augmentation index (AI), the ratio of the secondary rise in pressure and pulse pressure. AI can be limiting, because it depends not only on the magnitude of wave reflection but also on wave shapes and timing of incident and reflected waves. More accurate measures are obtainable after separation of pressure in its forward (P f ) and reflected (P b ) components. However, this calculation requires measurement of aortic flow. We explore the possibility of replacing the unknown flow by a triangular wave, with duration equal to ejection time, and peak flow at the inflection point of pressure (F tIP ) and, for a second analysis, at 30% of ejection time (F t30 ). Wave form analysis gave forward and backward pressure waves. Reflection magnitude (RM) and reflection index (RI) were defined as RM=P b /P f and RI=P b /(P f +P b ), respectively. Healthy subjects, including interventions such as exercise and Valsalva maneuvers, and patients with ischemic heart disease and failure were analyzed. RMs and RIs using F tIP and F t30 were compared with those using measured flow (F m ). Pressure and flow were recorded with high fidelity pressure and velocity sensors. Relations are: RM tIP =0.82RM mf +0.06 ( R 2 =0.79; n=24), RM t30 =0.79RM mf +0.08 ( R 2 =0.85; n=29) and RI tIP =0.89RI mf +0.02 ( R 2 =0.81; n=24), RI t30 =0.83RI mf +0.05 ( R 2 =0.88; n=29). We suggest that wave reflection can be derived from uncalibrated aortic pressure alone, even when no clear inflection point is distinguishable and AI cannot be obtained. Epidemiological studies should establish its clinical value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Mitchell, G. F., Parise, H., Benjamin, E. J., Larson, M. G., Keyes, M. J., Vita, J. A., Vasan, R. S., & Levy, D. (2004) · Hypertension · doi:10.1161/01.hyp.0000128420.01881.aa · Cited by 1,501
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Self-citationAortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
Self-citationReproducibility of pulse wave velocity and augmentation index measured by pulse wave analysis
Wilkinson, I. B., Fuchs, S. A., Jansen, I. M., Spratt, J. C., Murray, G. D., Cockcroft, J. R., & Webb, D. J. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816121-00033 · Cited by 924
Forward and backward waves in the arterial system
WESTERHOF, N., SIPKEMA, P., BOS, G. C. V. D., & ELZINGA, G. (1972) · Cardiovascular Research · doi:10.1093/cvr/6.6.648 · Cited by 681
Self-citationAsmar, R. G., London, G. M., O’Rourke, M. E., Safar, M. E., & for the REASON Project coordinators and investigators (2001) · Hypertension · doi:10.1161/hy1001.095774 · Cited by 449
Cited by
Arterial Wave Reflections and Incident Cardiovascular Events and Heart Failure
Chirinos, J. A., Kips, J. G., Jacobs, D. R., Brumback, L., Duprez, D. A., Kronmal, R., Bluemke, D. A., Townsend, R. R., Vermeersch, S., & Segers, P. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.054 · Cited by 431
Wang, K.-L., Cheng, H.-M., Sung, S.-H., Chuang, S.-Y., Li, C.-H., Spurgeon, H. A., Ting, C.-T., Najjar, S. S., Lakatta, E. G., Yin, F. C. P., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.139964 · Cited by 372
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Self-citationLarge Artery Stiffness Assessment Using SphygmoCor Technology
Butlin, M., & Qasem, A. (2016) · Pulse · doi:10.1159/000452448 · Cited by 244
Hashimoto, J., Nichols, W. W., O'Rourke, M. F., & Imai, Y. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2007.49 · Cited by 111
Metadata
- Authors
- Westerhof, B. E., Guelen, I., Westerhof, N., Karemaker, J. M., & Avolio, A.
- Venue
- Hypertension
- Published
- 2006-10
- Volume
- 48
- Issue
- 4
- Pages
- 595-601
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2124313450
- Cited by
- 309
- References
- 30
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of Wave Reflection in the Human Aorta From Pressure Alone: A Proof of Principle. https://app.cochat.ai/papers/10.1161/01.hyp.0000238330.08894.17
- The paper
- Westerhof, B. E., Guelen, I., Westerhof, N., Karemaker, J. M., & Avolio, A. (2006). Quantification of Wave Reflection in the Human Aorta From Pressure Alone: A Proof of Principle. Hypertension. https://doi.org/10.1161/01.hyp.0000238330.08894.17
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.