Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Experimental validation of quantitative coronary arteriography for determining pressure-flow characteristics of coronary stenosis.

Open access
Gould, K L, Kelley, K O, Bolson, E L·1982·Circulation

Abstract

The applicability of classic fluid dynamic equations to tapering stenoses in vasoactive, flexible coronary arteries in vivo and the validity of quantitative coronary arteriography was tested by comparing experimentally measured and x-ray-predicted pressure gradients at equal flows for left circum- flex stenoses in five dogs chronically instrumented with a balloon.occluder, flow probe, and proximal and distal catheters for.injection of contrast media or recording distal coronary pressure.Arterial borders on cut-film orthogonal arteriograms were digitized and computer processed into a three-dimensional recon- struction of the stenosis.The total pressure gradient was calculated from stenosis dimensions using classic fluid dynamic equations.Over the full range of flow, the correlation of x-ray-predicted and experimentally measured pressure gradient for 51 separate stenoses was y = 1.11x + 0.75, r = 0.95, p < 0.001, with a standard deviation about the regression line of 9.4 mm Hg and with 95% of x-ray-predicted values falling within ± 18.5 mm Hg of the experimentally measured values (95.% confidence limits).Mean experimentally measured and x-ray-predicted pressure gradients were 10.1 7.7 mm Hg (± SD) and 10.9 + 5.6 mmn Hg at low flow and 48.2 ± 23.1 mm Hg and 55.8 ± 28.8 mm Hg at high flow, respectively.The mean difference was 3.9 ± 4.3 mm Hg at rest flow and 11.9 ± 10.5 mm Hg at high flow.For all data over the entire range of flows, the frequency distribution of differences between x-ray-predicted and experimentally measured gradients was a bell-shaped curve with a peak, or mean difference, of + 4 mm Hg, a standard deviation of ± 9.8 mm Hg and 95% confidence limits for individual values of ± 19.6 mm Hg.These data demonstrate the validity of applying classic fluid dynamic theory to tapering stenoses in vivo.Quantitative coronary arteriography on the average or in individual instances approximately predicts the pressure gradient-flow characteristics of coronary arterial stenoses in intact animals.However, as indicated by the above measures of variability, there is considerable scatter in x-ray predictions that limits its applicability to individual clinical cases.We believe that this scatter is a result of difficulties in visually tracing arterial borders on arteriograms and can most likely be reduced by automatic border recognition techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.66.5.930

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 265

Metadata

Authors
Gould, K. L., Kelley, K. O., & Bolson, E. L.
Venue
Circulation
Published
1982-11
Volume
66
Issue
5
Pages
930-937
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1997210033
Cited by
265
References
6
FWCI
9.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental validation of quantitative coronary arteriography for determining pressure-flow characteristics of coronary stenosis. https://app.cochat.ai/papers/10.1161/01.cir.66.5.930
The paper
Gould, K. L., Kelley, K. O., & Bolson, E. L. (1982). Experimental validation of quantitative coronary arteriography for determining pressure-flow characteristics of coronary stenosis. Circulation. https://doi.org/10.1161/01.cir.66.5.930

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.