Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record.

Echoventriculography -- a simultaneous analysis of two-dimensional echocardiography and cineventriculography.

Erbel, R, Schweizer, P, Lambertz, H, Henn, G, Meyer, J, Krebs, W, Effert, S·1983·Circulation

Abstract

Two-dimensional echocardiography underestimates left ventricular volume compared with cineventriculography. To exclude the influence of difference in heart rate, blood pressure, respiration phases and any effect of the contrast material on left ventricular function, simultaneous studies of two-dimensional echocardiography and cineventriculography-echoventriculography were performed in 46 patients. Apical two-dimensional echocardiograms in the right anterior oblique (RAO) equivalent view were recorded before and during cineventriculography in the 30 degrees RAO projection. End-diastolic and end-systolic volumes (EDV and ESV) were calculated using a disc method with a semiautomatic computer system. The echo transducer position relative to the left ventricular apex and long axis was analyzed. For EDV determined by two-dimensional echocardiography and cineventriculography, the linear regression equation was y = 0.659x + 0.8, SEE = +/- 26.2 ml, r = 0.907. For ESV, the regression equation was y = 0.571x + 17.8, r = 0.938, SEE = +/- 18.6 ml, and for ejection fraction (EF) it was y = 0.606x + 13.0, r = 0.803, SEE = +/- 9.1%. Injection of contrast material resulted in only a small increase of stroke volume, caused by an increase of EDV as analyzed by echoventriculography. In all but two patients, the transducer position was found to be anterior and superior to the left ventricular anatomic apex, as evaluated by filming the echo transducer position during cineventriculography in 46 patients in the 30 degrees RAO projection and in 15 patients consecutively in the 60 degrees left anterior oblique and 30-40 degrees cranial projections. Thus, tangential cuts of the ventricle resulted in underestimation of diameters, long axis and ventricular volumes. These methodologic problems are exacerbated by slice-thickness artifacts. Furthermore, different outlining of left ventricular contour -- outer border of ventricular trabeculae for cine ventriculography and inner border for two-dimensional echocardiography -- seemed to result in underestimation of volume by echocardiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.67.1.205

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Erbel, R., Schweizer, P., Lambertz, H., Henn, G., Meyer, J., Krebs, W., & Effert, S.
Venue
Circulation
Published
1983-01
Volume
67
Issue
1
Pages
205-215
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2029369112
Cited by
201
References
0
FWCI
8.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Echoventriculography -- a simultaneous analysis of two-dimensional echocardiography and cineventriculography. https://app.cochat.ai/papers/10.1161/01.cir.67.1.205
The paper
Erbel, R., Schweizer, P., Lambertz, H., Henn, G., Meyer, J., Krebs, W., & Effert, S. (1983). Echoventriculography -- a simultaneous analysis of two-dimensional echocardiography and cineventriculography. Circulation. https://doi.org/10.1161/01.cir.67.1.205

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.