The DOI matches its Crossref record.
Echoventriculography -- a simultaneous analysis of two-dimensional echocardiography and cineventriculography.
Abstract
Two-dimensional echocardiography underestimates left ventricular volume compared with cineventriculography. To exclude the influence of difference in heart rate, blood pressure, respiration phases and any effect of the contrast material on left ventricular function, simultaneous studies of two-dimensional echocardiography and cineventriculography-echoventriculography were performed in 46 patients. Apical two-dimensional echocardiograms in the right anterior oblique (RAO) equivalent view were recorded before and during cineventriculography in the 30 degrees RAO projection. End-diastolic and end-systolic volumes (EDV and ESV) were calculated using a disc method with a semiautomatic computer system. The echo transducer position relative to the left ventricular apex and long axis was analyzed. For EDV determined by two-dimensional echocardiography and cineventriculography, the linear regression equation was y = 0.659x + 0.8, SEE = +/- 26.2 ml, r = 0.907. For ESV, the regression equation was y = 0.571x + 17.8, r = 0.938, SEE = +/- 18.6 ml, and for ejection fraction (EF) it was y = 0.606x + 13.0, r = 0.803, SEE = +/- 9.1%. Injection of contrast material resulted in only a small increase of stroke volume, caused by an increase of EDV as analyzed by echoventriculography. In all but two patients, the transducer position was found to be anterior and superior to the left ventricular anatomic apex, as evaluated by filming the echo transducer position during cineventriculography in 46 patients in the 30 degrees RAO projection and in 15 patients consecutively in the 60 degrees left anterior oblique and 30-40 degrees cranial projections. Thus, tangential cuts of the ventricle resulted in underestimation of diameters, long axis and ventricular volumes. These methodologic problems are exacerbated by slice-thickness artifacts. Furthermore, different outlining of left ventricular contour -- outer border of ventricular trabeculae for cine ventriculography and inner border for two-dimensional echocardiography -- seemed to result in underestimation of volume by echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recommendations for Quantitation of the Left Ventricle by Two-Dimensional Echocardiography
Schiller, N. B., Shah, P. M., Crawford, M., DeMaria, A., Devereux, R., Feigenbaum, H., Gutgesell, H., Reichek, N., Sahn, D., Schnittger, I., et al. (1989) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(89)80014-8 · Cited by 8,121
Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findings
Devereux, R. B., Alonso, D. R., Lutas, E. M., Gottlieb, G. J., Campo, E., Sachs, I., & Reichek, N. (1986) · The American Journal of Cardiology · doi:10.1016/0002-9149(86)90771-x · Cited by 6,229
Enriquez-Sarano, M., Miller, F. A., Hayes, S. N., Bailey, K. R., Tajik, A. J., & Seward, J. B. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00434-r · Cited by 380
Characterization of the rdar morphotype, a multicellular behaviour in Enterobacteriaceae
Römling, U. (2005) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-005-4557-x · Cited by 338
Quantitative Doppler assessment of valvular regurgitation.
Enriquez-Sarano, M., Bailey, K. R., Seward, J. B., Tajik, A. J., Krohn, M. J., & Mays, J. M. (1993) · Circulation · doi:10.1161/01.cir.87.3.841 · Cited by 325
Malm, S., Frigstad, S., Sagberg, E., Larsson, H., & Skjaerpe, T. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.068 · Cited by 323
Hoffmann, R., von Bardeleben, S., ten Cate, F., Borges, A. C., Kasprzak, J., Firschke, C., Lafitte, S., Al-Saadi, N., Kuntz-Hehner, S., Engelhardt, M., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi083 · Cited by 288
Pye, M., Quinn, A. C., & Cobbe, S. M. (1994) · Heart · doi:10.1136/hrt.71.6.511 · Cited by 280
McGowan, J. H., & Cleland, J. G. F. (2003) · American Heart Journal · doi:10.1016/s0002-8703(03)00248-5 · Cited by 279
Jenkins, C., Moir, S., Chan, J., Rakhit, D., Haluska, B., & Marwick, T. H. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn484 · Cited by 253
Metadata
- Authors
- Erbel, R., Schweizer, P., Lambertz, H., Henn, G., Meyer, J., Krebs, W., & Effert, S.
- Venue
- Circulation
- Published
- 1983-01
- Volume
- 67
- Issue
- 1
- Pages
- 205-215
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2029369112
- Cited by
- 201
- References
- 0
- FWCI
- 8.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.