The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Dynamic mechanisms in human coronary stenosis.
Open accessAbstract
At the clinical level, coronary stenoses frequently behave as though the obstruction to flow were variable and not as rigidly fixed as previously imagined. Pressure (energy) lost in flow through a stenosis is the primary determinant of its hemodynamic impact. Ischemic episodes occur when pressure distal to the stenosis falls below that needed to perfuse the subendocardium. Three important properties of the stenosis contribute to variation in its pressure loss. First, loss is proportional to the square of stenosis flow. Thus proper distribution of perfusion is doubly vulnerable to conditions such as exercise, anemia, or pharmacologic vasodilation, which ordinarily increase myocardial blood flow. Second, pressure loss is proportional to the inverse fourth power of minimum lumen diameter. As a result, seemingly small changes in diameter are amplified to large changes in stenosis resistance. Third, a compliant arc of normal arterial wall borders part of the lumen in the majority of coronary lesions. This extremely important morphologic feature of stenoses permits transient variation in stenosis lumen diameter in response to drugs or to variation in endogenous vasomotor activity or intraluminal pressure. Although our understanding is incomplete, many of the clinical features of coronary disease and its pharmacologic responses are explained in terms of these stenosis properties and their interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiologic basis for assessing critical coronary stenosis
Gould, K. L., Lipscomb, K., & Hamilton, G. W. (1974) · The American Journal of Cardiology · doi:10.1016/0002-9149(74)90743-7 · Cited by 1,532
Mechanisms of stenosis after arterial injury.
CLOWES, A. W., Reidy, M. A., & Clowes, M. M. (1983) · PubMed · Cited by 761
Gould, K. L., Kelley, K. O., & Bolson, E. L. (1982) · Circulation · doi:10.1161/01.cir.66.5.930 · Cited by 265
Self-citationBrown, B. G., Lee, A. B., Bolson, E. L., & Dodge, H. T. (1984) · Circulation · doi:10.1161/01.cir.70.1.18 · Cited by 240
Self-citationBrown, B. G., Josephson, M. A., Petersen, R. B., Pierce, C. D., Wong, M., Hecht, H. S., Bolson, E., & Dodge, H. T. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90323-4 · Cited by 227
Self-citationPathophysiology of Acute Myocardial Infarction, 1981
Oliva, P. B. (1981) · Annals of Internal Medicine · doi:10.7326/0003-4819-94-2-236 · Cited by 85
Cited by
Liu, M. W., Roubin, G. S., & King, S. B. (1989) · Circulation · doi:10.1161/01.cir.79.6.1374 · Cited by 927
Davies, M. J., Thomas, A. C., Knapman, P. A., & Hangartner, J. R. (1986) · Circulation · doi:10.1161/01.cir.73.3.418 · Cited by 532
Werns, S. W., Walton, J. A., Hsia, H. H., Nabel, E. G., Sanz, M. L., & Pitt, B. (1989) · Circulation · doi:10.1161/01.cir.79.2.287 · Cited by 322
Inflammation and cortisol response in coronary artery disease
Nijm, J., & Jonasson, L. (2009) · Annals of Medicine · doi:10.1080/07853890802508934 · Cited by 128
Coronary vasomotion during dynamic exercise: Influence of intravenous and intracoronary nicardipine
Kaufmann, P., Vassalli, G., Utzinger, U., & Hess, O. M. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00247-2 · Cited by 26
Metadata
- Authors
- Brown, B. G., Bolson, E. L., & Dodge, H. T.
- Venue
- Circulation
- Published
- 1984-12
- Volume
- 70
- Issue
- 6
- Pages
- 917-922
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2070972264
- Cited by
- 260
- References
- 6
- FWCI
- 25.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic mechanisms in human coronary stenosis. https://app.cochat.ai/papers/10.1161/01.cir.70.6.917
- The paper
- Brown, B. G., Bolson, E. L., & Dodge, H. T. (1984). Dynamic mechanisms in human coronary stenosis. Circulation. https://doi.org/10.1161/01.cir.70.6.917
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.