The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Regional wave travel and reflections along the human aorta: a study with six simultaneous micromanometric pressures.
Abstract
The human aorta and its terminal branches were investigated in normal subjects during elective cardiac catheterization to evaluate regional wave travel and arterial wave reflections. A specially designed catheter with six micromanometers equally spaced at 10 cm intervals was positioned with the tip sensor in the distal external iliac artery and the proximal sensor in the aortic arch. Simultaneous pressures were obtained and analyzed for foot-to-foot wave velocity, and Fourier analysis was used to derive apparent phase velocity. These quantities were assessed during control (n = 9), during Valsalva (n = 8) and Müller (n = 4) maneuvers, and during femoral artery occlusion by bilateral manual compression (n = 8). During control, regional cross-sectional areas, determined from aortography, and regional foot-to-foot pulse wave velocities were used to calculate the local reflection coefficient in the proximal descending aorta (gamma = 0.05), at the junction of the renal arteries (gamma = 0.43), and at the terminal aortic bifurcation (gamma = 0.13). To test the hypothesis that significant reflections originate in the aorta, at the level of the renal arteries, aortograms were used to design a latex tube model with geometric properties similar to the descending aorta. Velocities and reflection characteristics in the model and in vivo were compared. Inspection of thoracic aortic pressures under control conditions revealed a reflected wave originating from the region of the aorta at the level of the renal arterial branches while abdominal pressures exhibited reflection from a site peripheral to the terminal aortic bifurcation. In the low frequency range, apparent phase velocity was found to be higher proximal to the renal arteries as compared with at the distal sites. In addition, the minimum value occurred at a higher frequency in the lower thoracic aorta than at more distal sites. The effects of reflection on apparent wave velocity in the tube model were consistent with data obtained in vivo. The Valsalva maneuver diminished the reflection from the aortic region of the renal arteries, thus allowing the distal reflected wave to become more evident on the thoracic pressure waveforms. Bilateral femoral artery occlusion usually enhanced the distal reflection and the Müller maneuver usually resulted in small increases in reflections. In conclusion, the geometric and elastic nonuniformity of the aorta results in two major sites of arterial wave reflection that influence the aortic pressure waveforms in man.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
Self-citationAnalog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684
Self-citationMulti-branched model of the human arterial system
Avolio, A. P. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441895 · Cited by 517
Pressure-flow relationships and vascular impedance in man
Mills, C. J., Gabe, I. T., Gault, J. H., Mason, D. T., Ross, J., Braunwald, E., & Shillingford, J. P. (1970) · Cardiovascular Research · doi:10.1093/cvr/4.4.405 · Cited by 363
Vascular impedance in studies of arterial and cardiac function.
O'Rourke, M. F. (1982) · Physiological Reviews · doi:10.1152/physrev.1982.62.2.570 · Cited by 284
O'ROURKE, M. F., Blazek, J. V., Morreels, C. L., & Krovetz, L. J. (1968) · Circulation Research · doi:10.1161/01.res.23.4.567 · Cited by 241
Regional pulse-wave velocity in the arterial tree.
McDonald, D. A. (1968) · Journal of Applied Physiology · doi:10.1152/jappl.1968.24.1.73 · Cited by 222
The Input Impedance of an Assembly of Randomly Branching Elastic Tubes
Taylor, M. G. (1966) · Biophysical Journal · doi:10.1016/s0006-3495(66)86638-9 · Cited by 200
Pressure and flow waves in systemic arteries and the anatomical design of the arterial system.
O'Rourke, M. F. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.2.139 · Cited by 184
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1981) · Circulation · doi:10.1161/01.cir.63.1.122 · Cited by 175
Self-citationAN EXPERIMENTAL STUDY OF THE STANDING WAVES IN THE PULSE PROPAGATED THROUGH THE AORTA
Hamilton, W. F., & Dow, P. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.125.1.48 · Cited by 175
Grundlagen der Dynamik des Arterienpulses.
(1968) · Annals of Internal Medicine · doi:10.7326/0003-4819-69-6-1344_6 · Cited by 167
The arterial pulse in health and disease
O’Rourke, M. F. (1971) · American Heart Journal · doi:10.1016/0002-8703(71)90340-1 · Cited by 137
Oscillatory Flow Impedance in Electrical Analog of Arterial System:
Jager, G. N., Westerhof, N., & Noordergraaf, A. (1965) · Circulation Research · doi:10.1161/01.res.16.2.121 · Cited by 123
Self-citationLi, J. K., Melbin, J., Riffle, R. A., & Noordergraaf, A. (1981) · Circulation Research · doi:10.1161/01.res.49.2.442 · Cited by 115
Womersley, J. R. (1958) · Physics in Medicine and Biology · doi:10.1088/0031-9155/2/4/301 · Cited by 113
Wave Transmission through an Assembly of Randomly Branching Elastic Tubes
Taylor, M. G. (1966) · Biophysical Journal · doi:10.1016/s0006-3495(66)86689-4 · Cited by 108
Westerhof, N., Elzinga, G., & van den Bos, G. C. (1973) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478659 · Cited by 107
Self-citationWave-velocity in the proximal aorta
Nichols, W. W., & McDonald, D. A. (1972) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474213 · Cited by 87
Evaluation of the elasticity and characteristic impedance of the ascending aorta in man
Merillon, J. P., Motté, G., Fruchaud, J., Masquet, C., & Gourgon, R. (1978) · Cardiovascular Research · doi:10.1093/cvr/12.7.401 · Cited by 77
Reflection in the systemic arterial system: effects of aortic and carotid occlusion
van den Bos, G. C., Westerhof, N., Elzinga, G., et al. (1976) · Cardiovascular Research · doi:10.1093/cvr/10.5.565 · Cited by 75
Self-citationWave-travel in a Non-uniform Transmission Line, in Relation to Pulses in Arteries
Taylor, M. G. (1965) · Physics in Medicine and Biology · doi:10.1088/0031-9155/10/4/308 · Cited by 66
THE PATTERNS OF THE ARTERIAL PRESSURE PULSE
HAMILTON, W. F. (1944) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1944.141.2.235 · Cited by 64
Milnor, W. R., & Bertram, C. (1978) · Circulation Research · doi:10.1161/01.res.43.6.870 · Cited by 62
Kroeker, E. J., & Wood, E. H. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.8.5.483 · Cited by 61
The Measurement of Input Impedance and Apparent Phase Velocity in the Human Aorta
GABE, I. T., Karnell, J., Porjé, I. G., & Rudewald, B. (1964) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1964.tb02944.x · Cited by 59
Instantaneous Pressure Distribution Along the Human Aorta
Luchsinger, P. C., Snell, R. E., Patel, D. J., & Fry, D. L. (1964) · Circulation Research · doi:10.1161/01.res.15.6.503 · Cited by 53
Determination of the True Phase Velocity of Arterial Pressure Waves in Vivo
Cox, R. H. (1971) · Circulation Research · doi:10.1161/01.res.29.4.407 · Cited by 46
Effective length of the arterial system
Sipkema, P., & Westerhof, N. (1975) · Annals of Biomedical Engineering · doi:10.1007/bf02390974 · Cited by 44
Self-citationConstruction of aortic flow pulse from pressure pulse
Jw, R., & O'Brien, L. J. (1970) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1970.218.2.437 · Cited by 34
The Genesis of the Aortic Standing Wave
ALEXANDER, R. S. (1953) · Circulation Research · doi:10.1161/01.res.1.2.145 · Cited by 29
Greenwald, S. E., Newman, D. L., & Bowden, N. L. R. (1978) · Cardiovascular Research · doi:10.1093/cvr/12.7.407 · Cited by 28
Cited by
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Aboyans, V., Criqui, M. H., Abraham, P., Allison, M. A., Creager, M. A., Diehm, C., Fowkes, F. G. R., Hiatt, W. R., Jönsson, B., Lacroix, P., et al. (2012) · Circulation · doi:10.1161/cir.0b013e318276fbcb · Cited by 1,703
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Safar, M. E., Levy, B. I., & Struijker-Boudier, H. (2003) · Circulation · doi:10.1161/01.cir.0000069826.36125.b4 · Cited by 1,197
Clinical applications of arterial stiffness; definitions and reference values
O'Rourke, M. F., Staessen, J. A., Vlachopoulos, C., Duprez, D., & Plante, G. E. E. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02319-6 · Cited by 1,100
Metadata
- Authors
- Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P.
- Venue
- Circulation
- Published
- 1985-12
- Volume
- 72
- Issue
- 6
- Pages
- 1257-1269
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2003838565
- Cited by
- 454
- References
- 32
- FWCI
- 2.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.