The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Restenosis after successful coronary angioplasty in patients with single-vessel disease.
Open accessAbstract
To determine risk factors for restenosis, we studied 998 patients who underwent elective coronary angioplasty (PTCA) to native coronary arteries between July 1980 and July 1984. Restenosis, defined as a luminal narrowing of greater than 50% at follow-up, was present in 302 patients (30.2%). Univariate analysis of 29 factors revealed seven factors related to restenosis: vessel dilated (circumflex coronary artery 18%, right coronary artery 27%, left anterior descending artery 34%; p less than .01), final gradient of 15 mm Hg or less compared with greater than 15 mm Hg (27% vs 38%, p less than .01), duration of angina greater than 2 months compared with angina of shorter duration (27% vs 35%, p = .01), post-PTCA stenosis of 30% or less compared with 31% to 50% (28% vs 36%, p less than .025), stable vs unstable angina (26% vs 34%, p less than .05), presence vs absence of intimal dissection (26% vs 32%, p = .07), and female gender vs male gender (25% vs 32%, p = .08). Multivariate analysis revealed five factors independently related to increased risk of restenosis in the following order of importance: PTCA in the left anterior descending artery, absence of intimal dissection immediately after PTCA, final gradient greater than 15 mm Hg, a large residual stenosis after PTCA, and unstable angina. Restenosis after PTCA is a multifactorial problem. The hemodynamic and angiographic result at the time of PTCA significantly influences long-term outcome, but additional measures aimed at reducing the rate of recurrence of atherosclerotic plaque are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Austin, G. E., Ratliff, N. B., Hollman, J., Tabei, S., & Phillips, D. F. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80174-1 · Cited by 574
Self-citationThornton, M. A., Gruentzig, A. R., Hollman, J., King, S. B., & Douglas, J. S. (1984) · Circulation · doi:10.1161/01.cir.69.4.721 · Cited by 358
Self-citationTopography of atherosclerosis in the coronary arteries.
Mr, M., & Eggen, D. A. (1968) · PubMed · Cited by 201
Coronary angioplasty: Clinical and angiographic follow-up
Levine, S., Ewels, C. J., Rosing, D. R., & Kent, K. M. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90134-1 · Cited by 171
Wijns, W. C., Serruys, P. W. J. C., Reiber, J. H. C., de Feyter, P. J., van den Brand, M., Simoons, M. L., & Hugenholtz, P. G. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90375-3 · Cited by 138
Localization of lesions in the coronary circulation
Halon, D. A., Sapoznikov, D., Lewis, B. S., & Gotsman, M. S. (1983) · The American Journal of Cardiology · doi:10.1016/0002-9149(83)90506-4 · Cited by 91
Assessment of stenoses in coronary angioplasty. Inter- and intraobserver variability
Meier, B., Gruentzig, A. R., Goebel, N., Pyle, R., von Gosslar, W., & Schlumpf, M. (1983) · International Journal of Cardiology · doi:10.1016/0167-5273(83)90032-3 · Cited by 88
Self-citation
Cited by
Ryan, T. J., Faxon, D. P., Gunnar, R. M., Kennedy, J. W., King, S. B., Loop, F. D., Peterson, K. L., Reeves, T. J., Williams, D. O., & Winters, W. L. (1988) · Circulation · doi:10.1161/01.cir.78.2.486 · Cited by 2,123
Self-citationIntravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
Inhibition of Neointimal Smooth Muscle Accumulation After Angioplasty by an Antibody to PDGF
Ferns, G. A. A., Raines, E. W., Sprugel, K. H., Motani, A. S., Reidy, M. A., & Ross, R. (1991) · Science · doi:10.1126/science.1653454 · Cited by 1,065
Guidelines for percutaneous transluminal coronary angioplasty
Ryan, T. J. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90431-7 · Cited by 1,029
Liu, M. W., Roubin, G. S., & King, S. B. (1989) · Circulation · doi:10.1161/01.cir.79.6.1374 · Cited by 927
Self-citationNobuyoshi, M., Kimura, T., Nosaka, H., Mioka, S., Ueno, K., Yokoi, H., Hamasaki, N., Horiuchi, H., & Ohishi, H. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(88)80046-9 · Cited by 875
Ip, J. H., Fuster, V., Badimon, L., Badimon, J., Taubman, M. B., & Chesebro, J. H. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)92845-s · Cited by 765
Schwartz, L., Bourassa, M. G., Lespérance, J., Aldridge, H. E., Kazim, F., Salvatori, V. A., Henderson, M., Bonan, R., & David, P. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806303182603 · Cited by 692
Percutaneous Transluminal Coronary Angioplasty
Landau, C., Lange, R. A., & Hillis, L. D. (1994) · New England Journal of Medicine · doi:10.1056/nejm199404073301407 · Cited by 445
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Pathobiology of intimal hyperplasia
Davies, M. G., & Hagen, P.-O. (1994) · Journal of British Surgery · doi:10.1002/bjs.1800810904 · Cited by 413
Re-Stenosis after Successful Coronary Angioplasty
McBride, W., Lange, R. A., & Hillis, L. D. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806303182606 · Cited by 403
Nobuyoshi, M., Kimura, T., Ohishi, H., Horiuchi, H., Nosaka, H., Hamasaki, N., Yokoi, H., & Kim, K. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80111-1 · Cited by 400
Hirshfeld, J. W., Schwartz, J. S., Jugo, R., Macdonald, R. G., Goldberg, S., Savage, M. P., Bass, T. A., Vetrovec, G., Cowley, M., Taussig, A. S., et al. (1991) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(91)90783-6 · Cited by 391
Dehmer, G. J., Popma, J. J., van den Berg, E. K., Eichhorn, E. J., Prewitt, J. B., Campbell, W. B., Jennings, L., Willerson, J. T., & Schmitz, J. M. (1988) · New England Journal of Medicine · doi:10.1056/nejm198809223191201 · Cited by 379
Waller, B. F. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90248-9 · Cited by 318
Söder, H. K., Manninen, H. I., Jaakkola, P., Matsi, P. J., Räsänen, H. T., Kaukanen, E., Loponen, P., & Soimakallio, S. (2000) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(07)61332-3 · Cited by 293
Beyond 30 MHz [applications of high-frequency ultrasound imaging]
Lockwood, G. R., Turnball, D. H., Christopher, D. A., & Foster, F. S. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544513 · Cited by 286
Yokoi, H., Daida, H., Kuwabara, Y., Nishikawa, H., Takatsu, F., Tomihara, H., Nakata, Y., Kutsumi, Y., Ohshima, S., Nishiyama, S., et al. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00270-2 · Cited by 184
“50% at follow-up angiography, as determined by quantitative coronary angiography (24).”
Method
Metadata
- Authors
- Leimgruber, P. P., Roubin, G. S., Hollman, J., Cotsonis, G. A., Meier, B., Douglas, J. S., King, S. B., & Gruentzig, A. R.
- Venue
- Circulation
- Published
- 1986-04
- Volume
- 73
- Issue
- 4
- Pages
- 710-717
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2092972260
- Cited by
- 695
- References
- 7
- FWCI
- 73.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.