Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 403

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Re-Stenosis after Successful Coronary Angioplasty

McBride, Wade, Lange, Richard A., Hillis, L. David · 1988 · New England Journal of Medicine

Abstract

OVER the past decade, percutaneous transluminal coronary angioplasty has gained wide acceptance as the procedure of choice in many patients with atherosclerotic coronary artery disease. As experience with the procedure has grown, its rate of success has risen to approximately 90 percent and the incidence of acute complications has fallen; as a result, emergency coronary-artery bypass surgery is required in less than 4 percent of patients.1 2 3 Despite these improvements, re-Stenosis in the days, weeks, or months after successful angioplasty of a narrowed coronary artery occurs in 25 to 35 percent of patients,3 4 5 6 7 or 45 to 55 percent of those with . . .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1056/nejm198806303182606

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 403

Metadata

Authors
McBride, W., Lange, R. A., & Hillis, L. D.
Venue
New England Journal of Medicine
Published
1988-06-30
Volume
318
Issue
26
Pages
1734-1737
ISSN
  • 0028-4793 (ISSN-L)
  • 1533-4406
OpenAlex
W2022968291
Cited by
403
References
30
FWCI
38.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Re-Stenosis after Successful Coronary Angioplasty. https://app.cochat.ai/papers/10.1056/nejm198806303182606
The paper
McBride, W., Lange, R. A., & Hillis, L. D. (1988). Re-Stenosis after Successful Coronary Angioplasty. New England Journal of Medicine. https://doi.org/10.1056/nejm198806303182606

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.