CoChat

Diastolic filling dynamics in patients with aortic stenosis.

Open access
Murakami, T, Hess, O M, Gage, J E, Grimm, J, Krayenbuehl, H P · 1986 · Circulation
Cited by 140

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Left ventricular filling dynamics were investigated in 24 patients with aortic stenosis (AS). Biplane cineangiography was performed with simultaneous micromanometry in these 24 patients and in six control subjects. Twelve of the patients with AS had moderate hypertrophy with a left ventricular muscle mass index of less than 180 g/m2 (ASI group) and 12 had severe hypertrophy with an index of 180 g/m2 or more (AS2 group). Filling dynamics were also evaluated postoperatively in eight patients in the AS1 and six patients in the AS2 group. Preoperatively, end-diastolic and end-systolic volume indexes were larger and ejection fraction was lower in the AS2 compared with the control or AS1 group. Percent volume increase during the first half of diastole (%V1) was smaller in the AS1 than in the AS2 group. Peak filling rate in the first half of diastole (PFR 1) was higher in the AS2 than in the control or in AS1 group, while peak filling rate in the second half of diastole (PFR2) was considerably greater in the AS1 group than in the other two groups. The time constant of left ventricular pressure decline, an index of the rate of relaxation, was prolonged in the AS2 group. In contrast, mitral valve opening pressure (MVOP) was significantly higher in this group than in the other two groups. The constant of left ventricular chamber stiffness was slightly but not significantly greater in both AS groups than in the control subjects. After surgery in patients in the AS1 group, preoperatively reduced %V1 had increased and preoperatively enhanced PFR2 had decreased. In patients in the AS2 group, excluding one with a persistent low ejection fraction after surgery, preoperatively enhanced PFR1 decreased in association with a decrease in MVOP. Thus, left ventricular filling dynamics vary in patients with AS depending on the degree of left ventricular hypertrophy and systolic function. In patients with AS and moderate hypertrophy %V1 is slightly reduced but is compensated for by a forceful atrial contraction. In those with severe hypertrophy and systolic dysfunction increased driving pressure allows %V1 to remain within normal limits, despite prolonged left ventricular relaxation and decreased elastic recoil. Both changes in left ventricular filling dynamics tend to normalize after surgery in association with a reduction in left ventricular hypertrophy and/or an improvement of systolic function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.73.6.1162

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Murakami, T., Hess, O. M., Gage, J. E., Grimm, J., & Krayenbuehl, H. P.
Venue
Circulation
Published
1986-06
Volume
73
Issue
6
Pages
1162-1174
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2023791632
Cited by
140
References
1
FWCI
5.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.