Precision of measurements of right and left ventricular volume by cine computed tomography.
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Precise determination of left and right ventricular stroke volumes is limited with conventional imaging techniques. We determined whether right and left ventricular stroke volumes could be precisely measured with cine computed tomography (CT). Cine CT enables simultaneous imaging of the right and left ventricles at an 8 mm slice thickness with a maximal scanning rate of 17 frames/sec (50 msec acquisition intervals). In eight dogs, true right ventricular and left ventricular stroke volumes were determined by dividing thermodilution cardiac output by heart rate and/or with the use of an aortic electromagnetic flow probe implanted over a long term. After at least 5 sec of suspended respiration, cine CT images were acquired during central venous injection of a nonionic contrast agent. Multiple perturbations in stroke volume were induced in each dog by the administration of dobutamine, sodium pentobarbital, or sodium nitroprusside or by coronary artery occlusion. Right and left ventricular stroke volumes were obtained by Simpson's reconstruction of end-diastolic and end-systolic short-axis tomograms from apex to base. The cine CT left ventricular stroke volume (range 11 to 45 ml) correlated highly with the true left ventricular stroke volume (r = .99, slope = 1.01, y intercept = -0.2 ml, SEE = 1.5 ml, n = 25). The cine CT right ventricular stroke volume (range 11 to 34 ml) also correlated highly with the true right ventricular stroke volume (r = .98, slope = 0.9, y intercept = 2.2 ml, SEE = 1.7 ml, n = 15). In 12 studies, the mean difference between nearly simultaneous right and left ventricular stroke volumes by cine CT was 1.1 ml (range 0.1 to 3.2 ml). Calculation of right and left ventricular stroke volumes from data from cine CT were highly reproducible. Intraobserver variability in measurements of right ventricular stroke volume (r = 1.0, slope = 0.99, y intercept = 0.19 ml) and left ventricular stroke volume (r = 1.0, slope = 1.02, y intercept = -0.21 ml) was minimal. Interobserver variability in measurements of right ventricular stroke volume (r = .98, slope = 0.90, y intercept = 1.66 ml) and left ventricular stroke volume (r = .99, slope = 0.97, y intercept = -0.02 ml) was likewise minimal. Thus, precise and highly reproducible measurements of right and left ventricular stroke volumes can be obtained with cine CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The use of biplane angiocardiography for the measurement of left ventricular volume in man
Dodge, H. T., Sandler, H., Ballew, D. W., & Lord, J. D. (1960) · American Heart Journal · doi:10.1016/0002-8703(60)90359-8 · Cited by 1,277
Lewis, J. F., Kuo, L. C., Nelson, J. G., Limacher, M. C., & Quinones, M. A. (1984) · Circulation · doi:10.1161/01.cir.70.3.425 · Cited by 733
Left Ventricular Volumes and Ejection Fraction by Echocardiography
POMBO, J. F., TROY, B. L., & RUSSELL, R. O. (1971) · Circulation · doi:10.1161/01.cir.43.4.480 · Cited by 647
Usefulness and limitations of radiographic methods for determining left ventricular volume
Dodge, H. T., Sandler, H., Baxley, W. A., & Hawley, R. R. (1966) · The American Journal of Cardiology · doi:10.1016/0002-9149(66)90191-3 · Cited by 618
Left ventricular volume from paired biplane two-dimensional echocardiography.
Schiller, N. B., Acquatella, H., Ports, T. A., Drew, D., Goerke, J., Ringertz, H., Silverman, N. H., Brundage, B., Botvinick, E. H., Boswell, R., et al. (1979) · Circulation · doi:10.1161/01.cir.60.3.547 · Cited by 610
Thermodilution cardiac output determination with a single flow-directed catheter
Forrester, J. S., Ganz, W., Diamond, G., McHugh, T., Chonette, D. W., & Swan, H. J. C. (1972) · American Heart Journal · doi:10.1016/0002-8703(72)90429-2 · Cited by 501
Determination of Left Ventricular Volumes by Ultrasound
FORTUIN, N. J., HOOD, W. P., SHERMAN, M. E., & CRAIGE, E. (1971) · Circulation · doi:10.1161/01.cir.44.4.575 · Cited by 287
Ultrasound measurements of the left ventricle. A correlative study with angiocardiography
FEIGENBAUM, H. B. (1972) · Archives of Internal Medicine · doi:10.1001/archinte.129.3.461 · Cited by 271
Nongeometric determination of left ventricular volumes from equilibrium blood pool scans
Dehmer, G. J., Lewis, S. E., Hillis, L. D., Twieg, D., Falkoff, M., Parkey, R. W., & Willerson, J. T. (1980) · The American Journal of Cardiology · doi:10.1016/0002-9149(80)90648-7 · Cited by 261
Measurement of absolute left ventricular volume from gated blood pool studies.
Links, J. M., Becker, L. C., Shindledecker, J. G., Guzman, P., Burow, R. D., Nickoloff, E. L., Alderson, P. O., & Wagner, H. N. (1982) · Circulation · doi:10.1161/01.cir.65.1.82 · Cited by 255
Cited by
Frohlich, E. D., Apstein, C., Chobanian, A. V., Devereux, R. B., Dustan, H. P., Dzau, V., Fauad-Tarazi, F., Horan, M. J., Marcus, M., Massie, B., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199210013271406 · Cited by 782
Self-citationLorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Nagaya, N., Nishikimi, T., Okano, Y., Uematsu, M., Satoh, T., Kyotani, S., Kuribayashi, S., Hamada, S., Kakishita, M., Nakanishi, N., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00452-x · Cited by 574
Simons, D. B., Schwartz, R. S., Edwards, W. D., Sheedy, P. F., Breen, J. F., & Rumberger, J. A. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90367-v · Cited by 311
Self-citationMessika-Zeitoun, D., Bellamy, M., Avierinos, J.-F., Breen, J., Eusemann, C., Rossi, A., Behrenbeck, T., Scott, C., Tajik, J. A., & Enriquez-Sarano, M. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm199 · Cited by 171
Metadata
- Authors
- Reiter, S. J., Rumberger, J. A., Feiring, A. J., Stanford, W., & Marcus, M. L.
- Venue
- Circulation
- Published
- 1986-10
- Volume
- 74
- Issue
- 4
- Pages
- 890-900
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2054677269
- Cited by
- 165
- References
- 17
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.