The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Electrical alternans and cardiac electrical instability.
Abstract
We investigated the relationship between electrical alternans and cardiac electrical stability in a series of 20 dog experiments and in a pilot clinical study. Electrical alternans was detected in both the QRS complex and the ST-T wave by use of a novel multidimensional spectral technique. The magnitude of the alteration was expressed as the alternating electrocardiographic morphology index (AEMI), expressed as parts per million of waveform energy. Electrical stability in the dog preparations was assessed via the ventricular fibrillation threshold measurement, and in the clinical studies via programmed stimulation. In 10 dog experiments, systemic hypothermia resulted in a 60% decrease in ventricular fibrillation threshold (VFT) (p less than .0001) and a significant increase in both AEMI(QRS) form 3.7 +/- 3.0 to 1448 +/- 548 (p less than .0001) and AEMI(ST-T) from 43.9 +/- 18.4 to 19,178 +/- 5579 (p less than .0001). In 10 dog experiments, transient coronary artery ligation also resulted in a 60% decrease in VFT (p less than .0001), an increase from 76.3 +/- 46.5 to 245 +/- 11 in AEMI(QRS) (p less than .05), and an increase from 842 +/- 505 to 1365 +/- 392 in AEMI(ST-T) (p less than .002). In 119 observations in 20 animal experiments, the rank correlation between VFT and AEMI(QRS) was -.30 (p less than .001), with that between VFT and AEMI(ST-T) being -.55 (p less than .0001). In a double-blind pilot clinical trial consisting of 23 studies in 19 patients, the result of electrophysiologic testing was used as an independent measure of cardiac electrical stability. Alternation in waveform morphology identified the inducible patient population with a sensitivity of 92%, a positive predictivity of 70%, and a specificity of 50% (p less than .05). We conclude that analysis of subtle beat-to-beat variability in electrocardiographic morphology may provide a noninvasive measure of cardiac electrical stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple mathematical models with very complicated dynamics
May, R. M. (1976) · Nature · doi:10.1038/261459a0 · Cited by 7,001
Quantitative universality for a class of nonlinear transformations
Feigenbaum, M. J. (1978) · Journal of Statistical Physics · doi:10.1007/bf01020332 · Cited by 3,589
Schwartz, P. J., Periti, M., & Malliani, A. (1975) · American Heart Journal · doi:10.1016/0002-8703(75)90089-7 · Cited by 910
Universal behavior in nonlinear systems
Feigenbaum, M. J. (1983) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(83)90112-4 · Cited by 714
Schwartz, P. J., & Malliani, A. (1975) · American Heart Journal · doi:10.1016/0002-8703(75)90008-3 · Cited by 524
Fluctuations in T-wave morphology and susceptibility to ventricular fibrillation
Adam, D. R., Smith, J. M., Akselrod, S., Nyberg, S., Powell, A. O., & Cohen, R. J. (1984) · Journal of Electrocardiology · doi:10.1016/s0022-0736(84)80057-6 · Cited by 211
Self-citationNavarro‐López, F., Cinca, J., Sanz, G., Periz, A., Magriñá, J., & Betriu, A. (1978) · American Heart Journal · doi:10.1016/0002-8703(78)90369-1 · Cited by 56
Electrical alternans of giant U waves with multiple electrolyte deficits
Shimoni, Z., FLATAU, E., Schiller, D., Barzilay, E., & Kohn, D. (1984) · The American Journal of Cardiology · doi:10.1016/s0002-9149(84)80236-2 · Cited by 44
T-wave alternans associated with heart failure and hypomagnesemia in alcoholic cardiomyopathy.
LUOMANMÄKI, K., Heikkilä, J., & Hartikainen, M. (1975) · PubMed · Cited by 23
Romano-Ward prolonged QT syndrome with intermittent T wave alternans and atrioventricular block
Sharma, S., Nair, K. G., & Gadekar, H. A. (1981) · American Heart Journal · doi:10.1016/0002-8703(81)90143-5 · Cited by 19
Cited by
Sudden Death Due to Cardiac Arrhythmias
Huikuri, H. V., Castellanos, A., & Myerburg, R. J. (2001) · New England Journal of Medicine · doi:10.1056/nejmra000650 · Cited by 1,466
Electrical Alternans and Vulnerability to Ventricular Arrhythmias
Rosenbaum, D. S., Jackson, L. E., Smith, J. M., Garan, H., Ruskin, J. N., & Cohen, R. J. (1994) · New England Journal of Medicine · doi:10.1056/nejm199401273300402 · Cited by 1,143
Self-citationMechanism Linking T-Wave Alternans to the Genesis of Cardiac Fibrillation
Pastore, J. M., Girouard, S. D., Laurita, K. R., Akar, F. G., & Rosenbaum, D. S. (1999) · Circulation · doi:10.1161/01.cir.99.10.1385 · Cited by 817
Schwartz, P. J. (1997) · Current Problems in Cardiology · doi:10.1016/s0146-2806(97)80009-6 · Cited by 693
Berger, R. D., Kasper, E. K., Baughman, K. L., Marban, E., Calkins, H., & Tomaselli, G. F. (1997) · Circulation · doi:10.1161/01.cir.96.5.1557 · Cited by 614
Metadata
- Authors
- Smith, J. M., Clancy, E. A., Valeri, C. R., Ruskin, J. N., & Cohen, R. J.
- Venue
- Circulation
- Published
- 1988-01
- Volume
- 77
- Issue
- 1
- Pages
- 110-121
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2013157031
- Cited by
- 504
- References
- 10
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.