The DOI matches its Crossref record.
Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation.
Abstract
End-tidal CO2 concentration (ETCO2) may serve as a simple noninvasive measurement of the blood flow generated by precordial compression during cardiopulmonary resuscitation (CPR). In a mechanically ventilated porcine preparation of ventricular fibrillation, onset of fibrillation was associated with a rapid decrease in ETCO2 from 4.0 +/- 0.2% to less than 0.7 +/- 0.2%. With precordial compression, it increased to 1.9 +/- 0.3%. Animals that were successfully defibrillated after 12 min of CPR demonstrated an immediate increase in ETCO2. The ETCO2 increased from 1.9 +/- 0.3% to 4.9 +/- 0.3% over an interval of between 30 and 60 sec. These changes in ETCO2 were closely related to proportionally similar decreases and increases in cardiac output (CO), and a close correlation between ETCO2 and CO was demonstrated (r = .92). A similar highly significant correlation between ETCO2 and CO was also demonstrated during open-chest cardiac massage (r = .95). ETCO2 therefore serves as a noninvasive measure of pulmonary blood flow and therefore CO. In 17 successfully resuscitated animals. ETCO2 during precordial compression averaged 1.7 +/- 0.2%, whereas it was only 0.5 +/- 0.1% in five animals in whom resuscitation procedures were unsuccessful (p less than .001). Accordingly, ETCO2 prognosticates outcome during CPR and immediately identifies restoration of spontaneous circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
End-Tidal Carbon Dioxide Concentration during Cardiopulmonary Resuscitation
Falk, J. L., Rackow, E. C., & Weil, M. H. (1988) · New England Journal of Medicine · doi:10.1056/nejm198803103181005 · Cited by 466
Self-citationMonitor the quality of cardiopulmonary resuscitation in 2020
Genbrugge, C., Eertmans, W., & Salcido, D. D. (2020) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000000726 · Cited by 12
Metadata
- Authors
- Gudipati, C. V., Weil, M. H., Bisera, J., Deshmukh, H. G., & Rackow, E. C.
- Venue
- Circulation
- Published
- 1988-01
- Volume
- 77
- Issue
- 1
- Pages
- 234-239
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2087651862
- Cited by
- 329
- References
- 0
- FWCI
- 18.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation. https://app.cochat.ai/papers/10.1161/01.cir.77.1.234
- The paper
- Gudipati, C. V., Weil, M. H., Bisera, J., Deshmukh, H. G., & Rackow, E. C. (1988). Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation. Circulation. https://doi.org/10.1161/01.cir.77.1.234
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.