Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record.

Flow-mediated and reflex changes in large peripheral artery tone in humans.

Anderson, E A, Mark, A L·1989·Circulation

Abstract

Studies of peripheral blood vessels in humans have focused primarily on regulation of blood flow and vascular resistance, which are thought to reflect small vessel caliber. Recent studies in animals have identified flow-mediated and neurogenic changes in large artery diameter. This study tested for flow-mediated dilatation and reflex constriction of the brachial artery in humans. A dual-crystal pulsed Doppler system was used to measure brachial artery diameter and blood flow proximal to the antecubital fossa. To test for flow-mediated dilatation, flow through the brachial artery was altered by an occluding cuff placed on the forearm distal to the site of brachial artery flow and diameter measurement. Control blood flow was 123 +/- 20 ml/min, and brachial artery diameter was 4.74 +/- 0.17 mm (mean +/- SEM). By inflating the distal occluding cuff (distal circulatory arrest), flow was reduced through the brachial artery to 21 +/- 5 ml/min (p less than 0.005), and brachial artery diameter was reduced to 4.35 +/- 0.20 mm (p less than 0.001). By deflating the distal occluding cuff after 10 minutes (reactive hyperemia), brachial artery flow was increased to 358 +/- 55 ml/min (p less than 0.001), and diameter was increased to 5.6 +/- 0.19 mm (p less than 0.001). These interventions did not change systemic arterial pressure and, as measured in three subjects, caused only small changes in local brachial artery distending pressure. Thus, both increased and decreased brachial artery blood flow produced significant changes in brachial artery diameter without altering arterial distending pressure. These data provide evidence for flow-mediated dilatation in humans.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.79.1.93

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 274

Metadata

Authors
Anderson, E. A., & Mark, A. L.
Venue
Circulation
Published
1989-01
Volume
79
Issue
1
Pages
93-100
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1977527401
Cited by
274
References
0
FWCI
3.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flow-mediated and reflex changes in large peripheral artery tone in humans. https://app.cochat.ai/papers/10.1161/01.cir.79.1.93
The paper
Anderson, E. A., & Mark, A. L. (1989). Flow-mediated and reflex changes in large peripheral artery tone in humans. Circulation. https://doi.org/10.1161/01.cir.79.1.93

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.